Capillary ultrahigh-pressure liquid chromatography-mass spectrometry for fast and high resolution metabolomics separations

被引:16
|
作者
Sorensen, Matthew J. [1 ]
Kennedy, Robert T. [1 ,2 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
ultrahigh-pressure liquid chromatography; mass spectrometry; metabolomics; peak capacity; sub-2 micron particles; PEAK-CAPACITY; SLURRY CONCENTRATION; HIGH-EFFICIENCY; MICRODIALYSIS SAMPLES; RPLC SEPARATIONS; SLIP-FLOW; UPLC-MS; PARTICLES; COLUMNS; PERFORMANCE;
D O I
10.1016/j.chroma.2020.461706
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-MS is an important tool for metabolomics due its high sensitivity and broad metabolite coverage. The goal of improving resolution and decreasing analysis time in HPLC has led to the use of 5 - 15 cm long columns packed with 1.7 - 1.9 mu m particles requiring pressures of 8 - 12 kpsi. We report on the potential for capillary LC-MS based metabolomics utilizing porous C18 particles down to 1.1 mu m diameter and columns up to 50 cm long with an operating pressure of 35 kpsi. Our experiments show that it is possible to pack columns with 1.1 mu m porous particles to provide predicted improvements in separation time and efficiency. Using kinetic plots to guide the choice of column length and particle size, we packed 50 cm long columns with 1.7 mu m particles and 20 cm long columns with 1.1 mu m particles, which should produce equivalent performance in shorter times. Columns were tested by performing isocratic and gradient LC-MS analyses of small molecule metabolites and extracts from plasma. These columns provided approximately 100,000 theoretical plates for metabolite standards and peak capacities over 500 in 100 min for a complex plasma extract with robust interfacing to MS. To generate a given peak capacity, the 1.1 mu m particles in 20 cm columns required roughly 75% of the time as 1.7 mu m particles in 50 cm columns with both operated at 35 kpsi. The 1.1 mu m particle packed columns generated a given peak capacity nearly 3 times faster than 1.7 mu m particles in 15 cm columns operated at similar to 10 kpsi. This latter condition represents commercial state of the art for capillary LC. To consider practical benefits for metabolomics, the effect of different LC-MS variables on mass spectral feature detection was evaluated. Lower flow rates (down to 700 nL/min) and larger injection volumes (up to 1 mu L) increased the features detected with modest loss in separation performance. The results demonstrate the potential for fast and high resolution separations for metabolomics using 1.1 mu m particles operated at 35 kpsi for capillary LC-MS. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Ultrahigh-pressure liquid chromatography-mass spectrometry: An overview of the last decade
    Lopez-Ruiz, Rosalia
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 118 : 170 - 181
  • [2] Ultrahigh-Performance capillary liquid chromatography-mass spectrometry at 35 kpsi for separation of lipids
    Sorensen, Matthew J.
    Miller, Kelsey E.
    Jorgenson, James W.
    Kennedy, Robert T.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1611 (1611)
  • [3] Comparison of microcapillary column length and inner diameter investigated with gradient analysis of lipids by ultrahigh-pressure liquid chromatography-mass spectrometry
    Miller, Kelsey E.
    Jorgenson, James W.
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (22) : 4094 - 4102
  • [4] Compact Ultrahigh-Pressure Nanoflow Capillary Liquid Chromatograph
    Zhao, Xiaofeng
    Xie, Xiaofeng
    Sharma, Sonika
    Tolley, Luke T.
    Plisti, Alex
    Barnett, Hal E.
    Brisbin, Martin P.
    Swensen, Adam C.
    Price, John C.
    Farnsworth, Paul B.
    Tolley, H. Dennis
    Stearns, Stanley D.
    Lee, Milton L.
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 807 - 812
  • [5] Comprehensive Two-Dimensional Ultrahigh-Pressure Liquid Chromatography for Separations of Polymers
    Uliyanchenko, Elena
    Cools, Paul J. C. H.
    van der Wal, Sjoerdj
    Schoenmakers, Peter J.
    ANALYTICAL CHEMISTRY, 2012, 84 (18) : 7802 - 7809
  • [6] Myths in Ultrahigh-Pressure Liquid Chromatography
    Dong, Michael W.
    LC GC NORTH AMERICA, 2013, 31 (10) : 868 - +
  • [7] Current practice of liquid chromatography-mass spectrometry in metabolomics and metabonomics
    Gika, Helen G.
    Theodoridis, Georgios A.
    Plumb, Robert S.
    Wilson, Ian D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 87 : 12 - 25
  • [8] More Myths in Ultrahigh-Pressure Liquid Chromatography
    Dong, Michael W.
    LC GC EUROPE, 2013, 26 (11) : 637 - +
  • [9] Liquid Chromatography-Mass Spectrometry for Clinical Metabolomics: An Overview
    Furlani, Izadora L.
    Nunes, Estefane da Cruz
    Canuto, Gisele A. B.
    Macedo, Adriana N.
    Oliveira, Regina V.
    SEPARATION TECHNIQUES APPLIED TO OMICS SCIENCES: FROM PRINCIPLES TO RELEVANT APPLICATIONS, 2021, 1336 : 179 - 213
  • [10] Untargeted metabolomics by liquid chromatography-mass spectrometry for food authentication: A review
    Zhong, Peng
    Wei, Xiaoqun
    Li, Xiangmei
    Wei, Xiaoyi
    Wu, Shaozong
    Huang, Weijuan
    Koidis, Anastasios
    Xu, Zhenlin
    Lei, Hongtao
    COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2022, 21 (03): : 2455 - 2488