Image registration and subtraction to detect active T2 lesions in MS:: an interobserver study

被引:44
作者
Tan, IL
van Schijndel, RA
Fazekas, F
Filippi, M
Freitag, P
Miller, DH
Yousry, TA
Pouwels, PJW
Adèr, HJ
Barkhof, F
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Radiol, NL-1007 MB Amsterdam, Netherlands
[2] Free Univ Amsterdam, Med Ctr, Dept Clin Epidemiol & Biostat, NL-1081 BT Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, MR Ctr MS Res, NL-1007 MB Amsterdam, Netherlands
[4] Karl Franzens Univ Graz, Ndurol Univ Klin, Dept Neurol, A-8036 Graz, Austria
[5] Osped San Raffaele, Inst Sci, Dept Neurosci, Neuroimaging Res Unit, I-20132 Milan, Italy
[6] Kantonsspital Basel, Univ Poliklin, Abt Neuroradiol, CH-4031 Basel, Switzerland
[7] UCL Natl Hosp Neurol & Neurosurg, Inst Neurol, London WC1N 3BG, England
[8] Univ Munich, Neurol Klinikum Groshadern, D-81377 Munich, Germany
关键词
MR imaging; brain; multiple sclerosis; registration; substraction;
D O I
10.1007/s00415-002-0712-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Serial MRI studies are used to analyse change in multiple sclerosis (MS) lesion volume in clinical trials. As such an evaluation is very time consuming and subject to quantification errors, one might assess only the change in number or size of lesions using subtracted images. The advantage of subtracted images is that both new and/or enlarging and resolving and/or shrinking lesions can be evaluated, resulting in a more precise volume change than a net volume change. We studied the interobserver agreement in the detection of active MS lesions using paired dual-echo T-2-weighted spin-echo studies (3-mm slices) of 30 MS patients with a range of MS disease activity on MRI from treatment trials. Using an automatic matching algorithm based on mutual information, the follow-up scan was registered to baseline, after which subtracted images were obtained. After a training session with formulation of guidelines, six observers identified new, enlarging, resolving and shrinking lesions on subtracted images. Weighted kappa (kappa) values were calculated to assess interobserver agreement. Good agreement was found for new lesions (kappa 0.69 +/- 0.08), while moderate agreement was found for enlarging lesions (kappa 0.52 +/- 0.06). When new and enlarging lesions were combined, good agreement was found for "positive" activity (kappa 0.71 +/- 0.06). The interobserver agreement was poor for resolving lesions (kappa 0.31 +/- 0.07), and moderate for shrinking lesions (kappa 0.53 +/- 0.08). In conclusion, the use of subtracted images in the visual detection of new T-2 lesions resulted in a good level of interobserver agreement for "positive" disease activity. Subtraction of registered images is a reliable, time efficient method to assess disease progression in MS.
引用
收藏
页码:767 / 773
页数:7
相关论文
共 22 条
[1]  
Altman D.G., 1991, PRACTICAL STAT MED R, V1st, P403, DOI [10.1002/sim.4780101015, DOI 10.1002/SIM.4780101015]
[2]   Strategies for optimizing MRI techniques aimed at monitoring disease activity in multiple sclerosis treatment trials [J].
Barkhof, F ;
Filippi, M ;
Miller, DH ;
Tofts, P ;
Kappos, L ;
Thompson, AJ .
JOURNAL OF NEUROLOGY, 1997, 244 (02) :76-84
[3]   Improving interobserver variation in reporting gadolinium-enhanced MRI lesions in multiple sclerosis [J].
Barkhof, F ;
Filippi, M ;
van Waesberghe, JH ;
Molyneux, P ;
Rovaris, M ;
Nijeholt, GLA ;
Tubridy, N ;
Miller, DH ;
Yousry, TA ;
Radue, EW ;
Adèr, HJ .
NEUROLOGY, 1997, 49 (06) :1682-1688
[4]   THE EFFECT OF REPOSITIONING ERROR ON SERIAL MAGNETIC-RESONANCE-IMAGING SCANS - REPLY [J].
CAPRA, R ;
MARCIANO, N ;
GASPAROTTI, R .
ARCHIVES OF NEUROLOGY, 1993, 50 (06) :570-571
[5]   The effect of imprecise repositioning on lesion volume measurements in patients with multiple sclerosis [J].
Filippi, M ;
Marciano, N ;
Capra, R ;
Rocca, MA ;
Prandini, F ;
Gasparotti, R ;
Horsfield, MA ;
Comi, G .
NEUROLOGY, 1997, 49 (01) :274-276
[6]   Guidelines for using quantitative measures of brain magnetic resonance imaging abnormalities in monitoring the treatment of multiple sclerosis [J].
Filippi, M ;
Horsfield, MA ;
Adèr, HJ ;
Barkhof, F ;
Bruzzi, P ;
Evans, A ;
Frank, JA ;
Grossman, RI ;
McFarland, HF ;
Molyneux, P ;
Paty, DW ;
Simon, J ;
Tofts, PS ;
Wolinsky, JS ;
Miller, DH .
ANNALS OF NEUROLOGY, 1998, 43 (04) :499-506
[7]  
Filippi M, 1998, AM J NEURORADIOL, V19, P685
[8]   Lesion volume measurement in multiple sclerosis: How important is accurate repositioning [J].
GawneCain, ML ;
Webb, S ;
Tofts, P ;
Miller, DH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :705-713
[9]   THE EFFECT OF REPOSITIONING ERROR ON SERIAL MAGNETIC-RESONANCE-IMAGING SCANS [J].
GOODKIN, DE ;
VANDERBURGMEDENDORP, S ;
ROSS, J .
ARCHIVES OF NEUROLOGY, 1993, 50 (06) :569-570
[10]   Voxel similarity measures for 3-D serial MR brain image registration [J].
Holden, M ;
Hill, DLG ;
Denton, ERE ;
Jarosz, JM ;
Cox, TCS ;
Rohlfing, T ;
Goodey, J ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) :94-102