Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion

被引:27
|
作者
Koh, In Jun [1 ,3 ]
Park, Il Jung [2 ,3 ]
Lin, Charles C. [4 ]
Patel, Nilay A. [4 ,5 ]
Chalmers, Christen E. [4 ]
Maniglio, Mauro [6 ]
McGarry, Michelle H. [4 ]
Lee, Thay Q. [4 ,5 ]
机构
[1] St Pauls Hosp, Dept Orthopaed Surg, Wangsan Ro 180, Seoul 02559, South Korea
[2] Bucheon St Marys Hosp, Dept Orthopaed Surg, Bucheon 14647, South Korea
[3] Catholic Univ Korea, Coll Med, Dept Orthopaed Surg, Seoul 06591, South Korea
[4] Tibor Rubin VA Med Ctr, Orthopaed Biomech Lab, Long Beach, CA USA
[5] Univ Calif Irvine, Dept Orthopaed Surg, Irvine, CA USA
[6] Univ Hosp, Inselspital Bern, Dept Orthopaed & Traumatol, Bern, Switzerland
关键词
Patellofemoral kinematics; Total knee arthroplasty; Kinematic alignment; Mechanical alignment; FEMORAL COMPONENT; JOINT LINE; RETROPATELLAR PRESSURE; NO DIFFERENCE; ALIGNMENT; TKA; POSITION; STRESS;
D O I
10.1007/s00167-018-5270-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe implant positioning for kinematically aligned total knee arthroplasty (TKA) differs fundamentally from conventional mechanically aligned TKA. This difference may affect patellofemoral (PF) biomechanics after TKA. This cadaveric study tested the hypothesis that kinematically aligned TKA would restore PF biomechanics to the native condition better than mechanically aligned TKA.MethodsSeven pairs (14 knees) of fresh-frozen cadavers were tested. All specimens were mounted on a customized knee-testing system and digitized using a Microscribe 3DLX instrument (Revware Inc., Raleigh, NC, USA) to measure patellar kinematics in terms of patellar varus/valgus rotation, medial/lateral position, flexion/extension rotation and proximal/distal position at knee flexion angles of 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees. The medial and lateral PF joint contact pressure distributions at 120 degrees of knee flexion were measured using a K-scan system (Tekscan Inc., Boston, MA, USA). All patellae remained unresurfaced. For each pair, one knee was randomly assigned to kinematically aligned TKA and the other to mechanically aligned TKA performed using the conventional measured resection technique. During kinematically aligned TKA, the amount of femur and tibia resected was equivalent to implant thickness to maintain the patient-specific joint line. All patellar kinematics were measured and compared between the native condition and after surgery.ResultsThe patellae of mechanically aligned TKA rotated more valgus and was positioned more laterally compared with those of kinematically aligned TKA at knee flexion angles 90 degrees. Neither the patellar flexion/extension rotation nor the proximal/distal position differed between either prosthetic knee design and the native knee at all flexion angles. The contact pressure distribution between the medial and lateral PF joint after kinematically aligned TKA were similar to those of the native knee, while the lateral PF joint contact pressure after mechanically aligned TKA was higher than that of the native knee (p=0.038).ConclusionsKinematically aligned TKA better restores patellar kinematics and PF contact pressure distribution to the native condition than mechanically aligned TKA during deep knee flexion. These findings provide clues to understand why kinematically aligned TKA is associated with less anterior knee pain and better PF functional performance compared to mechanically aligned TKA. Patients undergoing kinematically aligned TKA may experience a more normal feeling during deep knee flexion activities.
引用
收藏
页码:1520 / 1528
页数:9
相关论文
共 50 条
  • [1] Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion
    In Jun Koh
    Il Jung Park
    Charles C. Lin
    Nilay A. Patel
    Christen E. Chalmers
    Mauro Maniglio
    Michelle H. McGarry
    Thay Q. Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1520 - 1528
  • [2] Kinematically aligned total knee arthroplasty reproduces more native rollback and laxity than mechanically aligned total knee arthroplasty: A matched pair cadaveric study
    Koh, In Jun
    Lin, Charles C.
    Patel, Nilay A.
    Chalmers, Christen E.
    Maniglio, Mauro
    Bin Han, Sung
    McGarry, Michelle H.
    Lee, Thay Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (04) : 605 - 611
  • [3] Kinematically Aligned Total Knee Arthroplasty or Mechanically Aligned Total Knee Arthroplasty
    Takahashi, Tsuneari
    Ansari, Juned
    Pandit, Hemant G.
    JOURNAL OF KNEE SURGERY, 2018, 31 (10) : 999 - 1006
  • [4] Kinematically aligned total knee arthroplasty restores more native medial collateral ligament strain than mechanically aligned total knee arthroplasty
    Lim, Dohyung
    Kwak, Dai-Soon
    Kim, Minji
    Kim, Seoyeong
    Cho, Ho-Jung
    Choi, Jae Hyuk
    Koh, In Jun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (08) : 2815 - 2823
  • [5] Limitations of the knee society score in kinematically aligned total knee arthroplasty
    Leica, Alexandra
    Sava, Manuel-Paul
    Khan, Zainab-Aqeel
    Hugli, Rolf W.
    Hirschmann, Michael T.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [6] Radiographic evaluation of patellofemoral alignment in kinematically aligned total knee arthroplasty: A comparative study with mechanically aligned total knee arthroplasty
    Nagai, Katsuya
    Niki, Yasuo
    Kobayashi, Shu
    Harato, Kengo
    Nagura, Takeo
    Matsumoto, Morio
    Nakamura, Masaya
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2021, 26 (06) : 1043 - 1050
  • [7] Posterior stabilized total knee arthroplasty reproduces natural joint laxity compared to normal in kinematically aligned total knee arthroplasty: a matched pair cadaveric study
    Koh, In Jun
    Chalmers, Christen E.
    Lin, Charles C.
    Park, Soo Bin
    McGarry, Michelle H.
    Lee, Thay Q.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (01) : 119 - 127
  • [8] Kinematically aligned total knee arthroplasty restores more native medial collateral ligament strain than mechanically aligned total knee arthroplasty
    Dohyung Lim
    Dai-Soon Kwak
    Minji Kim
    Seoyeong Kim
    Ho-Jung Cho
    Jae Hyuk Choi
    In Jun Koh
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 2815 - 2823
  • [9] Kinematically aligned total knee arthroplasty: alternative standardized technique?
    Matsumoto, Tomoyuki
    Takayama, Koji
    Ishida, Kazunari
    Hayashi, Shinya
    Hashimoto, Shingo
    Kuroda, Ryosuke
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5
  • [10] Kinematically aligned TKA restores physiological patellofemoral biomechanics in the sagittal plane during a deep knee bend
    Nicolet-Petersen, Stephanie
    Saiz, Augustine
    Shelton, Trevor
    Howell, Stephen
    Hull, Maury L.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1497 - 1507