Numerical study of heat loss from a non-evacuated receiver of a solar collector

被引:21
作者
Patil, Ramchandra G. [1 ]
Kale, Dhanaji M. [1 ]
Panse, Sudhir V. [1 ]
Joshi, Jyeshtharaj B. [1 ,2 ]
机构
[1] Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
关键词
Solar collector receiver; Non-evacuated receivers; Non-uniform temperature distribution; Heat loss; CRITICAL IMPELLER SPEED; NATURAL-CONVECTION; SOLID SUSPENSION; PERFORMANCE; DESIGN;
D O I
10.1016/j.enconman.2013.11.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat loss from receivers of solar collectors is a major reason for drop in their efficiency. Receiver pipes enclosed in glass tubes with evacuated annulus show considerable reduction in heat losses. However, manufacturing and maintenance costs for such receivers are high. An inexpensive alternative is a similar receiver with non-evacuated annulus. This paper presents a numerical study of heat loss from a non-evacuated receiver typically used in parabolic trough collectors, generating moderate temperatures and designed particularly for process heat applications. In order to come closer to the realistic situation, rather than assuming uniform temperature distribution on it, receiver pipe temperature has been assumed to be varying along the surface. Sinusoidal and square wave functions are employed in modeling, since actual temperature distributions on solar receiver pipes are combinations of these two functions. Main goal of the paper is to optimize the design of the non-evacuated solar receiver for minimum heat loss, by using CFD technique. Also effects on heat loss from receivers due to different parameters like average temperature (Ta) of the pipe, non-uniformity in the temperature (a) along its surface, hour angle (gamma), denoting position of the sun in the sky and radius ratio (RR) of radius of receiver pipe to that of outer glass tube have been studied. It is seen that as non-uniformity in temperature distribution increases in both types of temperature distribution, heat losses from receiver pipes decrease up to 10%. Also as hour angle increases from 00 to 90, heat loss decreases by 20% in case of sinusoidal temperature distribution and 24% in case of square wave temperature distribution. The effect of radius ratio (RR) on heat loss has been studied. In present study, we found out that 1.375 is critical radius ratio for which heat losses from receiver are minimum (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 32 条
[1]   Numerical study of conduction and convection heat losses from a half-insulated air-filled annulus of the receiver of a parabolic trough collector [J].
Al-Ansary, Hany ;
Zeitoun, O. .
SOLAR ENERGY, 2011, 85 (11) :3036-3045
[2]  
Alshahrani D, 2005, ALEXANDRIA ENG J, V44, P813
[3]  
[Anonymous], 1998, 7 AIAA ASME JOINT TH
[4]   Three-dimensional numerical study of heat transfer characteristics in the receiver tube of parabolic trough solar collector [J].
Cheng, Z. D. ;
He, Y. L. ;
Xiao, J. ;
Tao, Y. B. ;
Xu, R. J. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) :782-787
[5]   Numerical investigation of parabolic trough receiver performance with outer vacuum shell [J].
Daniel, Premjit ;
Joshi, Yashavant ;
Das, Abhik K. .
SOLAR ENERGY, 2011, 85 (09) :1910-1914
[6]  
EISherbiny S. M., 2004, ALEX ENG J, V43, P297
[7]   Cost effective design of compound parabolic collector for steam generation [J].
Gudekar, Ajitkumar S. ;
Jadhav, Atul S. ;
Panse, Sudhir V. ;
Joshi, Jyeshtharaj B. ;
Pandit, Aniruddha B. .
SOLAR ENERGY, 2013, 90 :43-50
[8]  
Gudekar AS, 2009, THESIS U MUMBAI, P287
[9]   Performance analysis of a novel and cost effective CPC system [J].
Jadhav, Atul S. ;
Gudekar, Ajitkumar S. ;
Patil, Ramchandra G. ;
Kale, Dhanaji M. ;
Panse, Sudhir V. ;
Joshi, Jyeshtharaj B. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 66 :56-65
[10]  
JOSHI JB, 1980, T I CHEM ENG-LOND, V58, P155