In vitro study of magnetic particle seeding for implant-assisted-magnetic drug targeting: Seed and magnetic drug carrier particle capture

被引:22
作者
Aviles, Misael O. [1 ]
Ebner, Armin D. [1 ]
Ritter, James A. [1 ]
机构
[1] Univ S Carolina, Dept Chem Engn, Swearingen Engn Ctr, Columbia, SC 29208 USA
基金
美国国家科学基金会;
关键词
Magnetic drug targeting; MDT; Drug delivery; High-gradient magnetic separation; HGMS; Ferromagnetic particle; Nanoparticle; Magnetite; Magnetic seed; Magnetic drug carrier particle; DELIVERY; MODEL;
D O I
10.1016/j.jmmm.2009.02.091
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An implant-assisted-magnetic drug targeting system using seed particles as the implant to increase the capture of magnetic drug carrier particles (MDCPs) in capillary tissue was studied in vitro. Dextran-coated magnetite particles were used as seeds, polydivinylbenzene magnetite particles were used as MDCPs, and a polyethylene porous cylinder was used as surrogate capillary tissue. The results showed that seeds could be magnetically captured first and then used to magnetically capture the MDCPs, causing a significant increase in their collection compared to when the seeds were absent. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1586 / 1590
页数:5
相关论文
共 18 条
[1]   Isolated swine heart ventricle perfusion model for implant assisted-magnetic drug targeting [J].
Aviles, Misael O. ;
Mangual, Jan O. ;
Ebner, Armin D. ;
Ritter, James A. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2008, 361 (1-2) :202-208
[2]   In vitro study of magnetic particle seeding for implant assisted-magnetic drug targeting [J].
Aviles, Misael O. ;
Ebner, Armin D. ;
Ritter, James A. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2008, 320 (21) :2640-2646
[3]   In vitro study of ferromagnetic stents for implant assisted-magnetic drug targeting [J].
Aviles, Misael O. ;
Chen, Haitao ;
Ebner, Armin D. ;
Rosengart, Axel J. ;
Kaminski, Michael D. ;
Ritter, James A. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 311 (01) :306-311
[4]   Ferromagnetic seeding for the magnetic targeting of drugs and radiation in capillary beds [J].
Aviles, Misael O. ;
Ebner, Armin D. ;
Ritter, James A. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 310 (01) :131-144
[5]   Theoretical analysis of a transdermal ferromagnetic implant for retention of magnetic drug carrier particles [J].
Avilés, MO ;
Ebner, AD ;
Chen, HT ;
Rosengart, AJ ;
Kaminski, MD ;
Ritter, JA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :605-615
[6]   Analysis of magnetic drug carrier particle capture by a magnetizable intravascular stent: 1. Parametric study with single wire correlation [J].
Chen, HT ;
Ebner, AD ;
Rosengart, AJ ;
Kaminski, MD ;
Ritter, JA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 284 :181-194
[7]   Analysis of magnetic drug carrier particle capture by a magnetizable intravascular stent-2: Parametric study with multi-wire two-dimensional model [J].
Chen, HT ;
Ebner, AD ;
Kaminski, MD ;
Rosengart, AJ ;
Ritter, JA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :616-632
[8]   Validation of high gradient magnetic field based drug delivery to magnetizable implants under flow [J].
Forbes, Zachary G. ;
Yellen, Benjamin B. ;
Halverson, Derek S. ;
Fridman, Gregory ;
Barbee, Kenneth A. ;
Friedman, Gary .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) :643-649
[9]   An approach to targeted drug delivery based on uniform magnetic fields [J].
Forbes, ZG ;
Yellen, BB ;
Barbee, KA ;
Friedman, G .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (05) :3372-3377
[10]  
GERBER R, 1994, NATO ASI SERIES E, V253