Evaluation of the Lower Trapezius Muscle Using Ultrasound Panoramic View (a Novel Approach): An Intra- and Inter-Rater Reliability Study

被引:1
作者
Fernandez-Carnero, Samuel [1 ]
Garrido-Marin, Alejandro [2 ]
Achalandabaso-Ochoa, Alexander [3 ]
Ferragut-Garcias, Alejandro [4 ]
Fernandez-Matias, Ruben [5 ]
Pecos-Martin, Daniel [1 ]
Gallego-Izquierdo, Tomas [1 ]
机构
[1] Alcala Univ, Dept Physiotherapy & Nursing, Alcala De Henares 28871, Spain
[2] CARMASALUD, Madrid 28037, Spain
[3] Univ Jaen, Dept Hlth Sci, Jaen 23071, Andalucia, Spain
[4] Islas Baleares Univ, Dept Nursing & Physiotherapy, Ciudad De Palma 07122, Spain
[5] Alcala Univ, Res Inst Phys Therapy & Pain, Alcala De Henares 28871, Spain
关键词
lower trapezius; panoramic view; ultrasound; reliability; TEST-RETEST RELIABILITY; CROSS-SECTIONAL AREA; SONOGRAPHIC EVALUATION; FOLLOW-UP; SIZE; AGREEMENT; EXERCISES; WOMEN;
D O I
10.3390/ijerph17197123
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The panoramic view ultrasound remains uncommon in clinical practice, probably because of its difficulty, high-cost, and lack of research. Morphological changes in muscles have been demonstrated to be related to symptomatology and provide data of interest for clinical assessment. Thus, the aim of this study was to evaluate the measurement reliability of the length of the lower trapezius muscle with the panoramic view ultrasound using a novel tool, SIG_VIP (R). Twenty healthy volunteers were measured by two expert sonographers using the SIG_VIP (R) tool with a novel approach. Statistical analyses were performed with the R software. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman plots were calculated. All the results indicated good intra-rater reliability (ICC3,1, 0.92 to 0.96; SEM, 0.59 to 0.85; MDC, 1.64 to 2.35) and inter-rater reliability (ICC3,2, 0.84 to 0.89; SEM, 1.22 to 1.53; MDC, 3.39 to 4.25). The novel system used with the described methodology can reliably measure the length of the inferior fibers of the trapezius muscle. Further research must be conducted to evaluate the reliability in patients and how pathology is related to the length of the lower trapezius muscle.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 34 条
[1]   Panoramic ultrasonography is a valid method to measure changes in skeletal muscle cross-sectional area [J].
Ahtiainen, Juha P. ;
Hoffren, Merja ;
Hulmi, Juha J. ;
Pietikainen, Mikko ;
Mero, Antti A. ;
Avela, Janne ;
Hakkinen, Keijo .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) :273-279
[2]   Sonographic Evaluation of the Distal Iliopsoas Tendon Using a New Approach [J].
Balius, Ramon ;
Pedret, Carles ;
Blasi, Marc ;
Miguel, Maribel ;
Vallejo, Beatriz ;
Margalet, Eric ;
Bong, David A. ;
Martinoli, Carlo .
JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (11) :2021-2030
[3]  
Barfod K.W., 2018, ABSTRACTS, V52, pA4, DOI [10.1136/bjsports-2018-099334.11, DOI 10.1136/BJSPORTS-2018-099334.11]
[4]   Validation of a novel ultrasound measurement of achilles tendon length [J].
Barfod, Kristoffer Weisskirchner ;
Riecke, Anja Falk ;
Boesen, Anders ;
Hansen, Philip ;
Maier, Jens Friedrich ;
Dossing, Simon ;
Troelsen, Anders .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) :3398-3406
[5]   Efficacy of pelvic floor muscle training and hypopressive exercises for treating pelvic organ prolapse in women: randomized controlled trial [J].
Bernardes, Bruno Teixeira ;
Magalhaes Resende, Ana Paula ;
Stuepp, Liliana ;
Oliveira, Emerson ;
Castro, Rodrigo Aquino ;
Katalin Jarmy di Bella, Zsuzsanna Ilona ;
Batista Castello Girao, Manoel Joao ;
Ferreira Sartori, Marair Gracio .
SAO PAULO MEDICAL JOURNAL, 2012, 130 (01) :5-9
[6]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[7]  
Fernandez-Carnero S., 2017, Sistema de Guiado para Vision Panoramica Ecografica (SIG_VIP)-Universidad de Alcala Patent Petition Number, Patent No. [P201700686, 201700686]
[8]   Muscle MRI findings in facioscapulohumeral muscular dystrophy [J].
Gerevini, Simonetta ;
Scarlato, Marina ;
Maggi, Lorenzo ;
Cava, Mariangela ;
Caliendo, Giandomenico ;
Pasanisi, Barbara ;
Falini, Andrea ;
Previtali, Stefano Carlo ;
Morandi, Lucia .
EUROPEAN RADIOLOGY, 2016, 26 (03) :693-705
[9]  
Gwet K.L., 2010, HDB INTER RATER RELI
[10]   Changes in multifidus and abdominal muscle size in response to microgravity: possible implications for low back pain research [J].
Hides, J. A. ;
Lambrecht, G. ;
Stanton, W. R. ;
Damann, V. .
EUROPEAN SPINE JOURNAL, 2016, 25 :S175-S182