Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

被引:37
作者
Fernandez-Vigo, Jose Ignacio [1 ,3 ]
Macarro-Merino, Ana [3 ]
Fernandez-Vigo, Cristina [3 ]
Fernandez-Vigo, Jose Angel [3 ,4 ]
Martinez-De-La-Casa, Jose Maria [1 ]
Fernandez-Perez, Cristina [2 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Ophthalmol, Madrid, Spain
[2] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Prevent Med, Madrid, Spain
[3] Ctr Int Oftalmol Avanzada, C Zurbano 71, Madrid 28010, Spain
[4] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
PHAKIC INTRAOCULAR-LENS; ANTERIOR-CHAMBER DEPTH; 3-YEAR FOLLOW-UP; HIGH MYOPIA; ULTRASOUND BIOMICROSCOPY; CATARACT DEVELOPMENT; ICL IMPLANTATION; CENTRAL VAULT; IRIDOTOMY; EYES;
D O I
10.1016/j.ajo.2015.11.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. DESIGN: Prospective interventional case series. METHODS: In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3,months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 mu m anterior to the scleral spur (A0D500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. RESULTS: Preoperative TIA was 48.7 +/- 8.7, 48.2 +/- 8.7, and 48.7 +/- 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P = 1.000). Following ICL implant, corresponding values fell to 31.2 +/- 11.5, 30.0 +/- 10.7, and 29.7 +/- 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 +/- 12.3, 30.1 +/- 11.9, and 29.8 +/- 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P = .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = .309; P = .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R-2 = .907). CONCLUSIONS: Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 38 条
[21]   Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation [J].
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Kawamorita, Takushi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) :1582-1586
[22]   Optimization of an Implantable Collamer Lens Sizing Method Using High-Frequency Ultrasound Biomicroscopy [J].
Kojima, Takashi ;
Yokoyama, Sho ;
Ito, Mayuka ;
Horai, Rie ;
Hara, Shuya ;
Nakamura, Tomoaki ;
Ichikawa, Kazuo .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (04) :632-637
[23]   Posterior Chamber Phakic Implantable Collamer Lens: Changes in Vault During 1 Year [J].
Kojima, Takashi ;
Maeda, Masahiro ;
Yoshida, Yoko ;
Ito, Mayuka ;
Nakamura, Tomoaki ;
Hara, Shuya ;
Ichikawa, Kazuo .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) :327-332
[24]   Posterior synechiae after Nd:YAG laser iridotomy:: a clinical study [J].
Kraemer, C ;
Gramer, E .
OPHTHALMOLOGE, 1998, 95 (09) :625-632
[25]   Intractable secondary glaucoma from hyphema following YAG iridotomy [J].
Kumar, N ;
Feyi-Waboso, A .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2005, 40 (01) :85-86
[26]   Effect of Accommodation on Vaulting and Movement of Posterior Chamber Phakic Lenses in Eyes With Implantable Col lamer Lenses [J].
Lee, Hun ;
Kang, David Sung Yong ;
Ha, Byoung Jin ;
Choi, Moonjung ;
Kim, Eung Kweon ;
Seo, Kyoung Yul ;
Kim, Tae-Im .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (04) :710-716
[27]   Dynamic Vaulting Changes in V4c versus V4 Posterior Chamber Phakic Lenses Under Differing Lighting Conditions [J].
Lee, Hun ;
Kang, Sung Yong ;
Seo, Kyoung Yul ;
Chung, Byunghoon ;
Choi, Jin Young ;
Kim, Kyu Seo ;
Kim, Tae-Im .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (06) :1199-1204
[28]   Comparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography [J].
Leung, C. K. ;
Palmiero, P-M ;
Weinreb, R. N. ;
Li, H. ;
Sbeity, Z. ;
Dorairaj, S. ;
Leung, D. ;
Liu, S. ;
Liebmann, J. M. ;
Congdon, N. ;
Lam, D. S. ;
Ritch, R. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (09) :1184-1189
[29]   Clinical Results of Posterior Chamber Phakic Intraocular Lens Implantation in Eyes With Low Anterior Chamber Depth [J].
Lim, Dong Hui ;
Lee, Min Gyu ;
Chung, Eui-Sang ;
Chung, Tae-Young .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) :447-454
[30]   Collagen copolymer posterior chamber Cross Mark phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up [J].
Lisa, Carlos ;
Fernando Alfonso, Jose ;
Alfonso-Bartolozzi, Belen ;
Fernandez-Vega, Luis ;
Perez-Vives, Cari ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) :98-104