Office blood pressure measurement in the 21st century

被引:23
作者
Myers, Martin G. [1 ,2 ]
Asmar, Roland [3 ]
Staessen, Jan A. [4 ,5 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Schulich Heart Program, Div Cardiol, Toronto, ON, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
[3] Fdn Med Res Inst, Paris, France
[4] Univ Leuven, Dept Cardiovasc Sci, Studies Coordinating Ctr, Res Unit Hypertens & Cardiovasc Epidemiol, Leuven, Belgium
[5] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
关键词
automated sphygmomanometers; blood pressure; hypertension diagnosis; measurement; HYPERTENSION; RISK;
D O I
10.1111/jch.13276
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Measurement of blood pressure (BP) using the auscultatory method must follow specific rules and conditions to be reliable. Nonetheless, these requirements are often not followed in clinical practice, resulting in inaccurate BP readings. Simply replacing manual sphygmomanometers with an oscillometric device may still produce readings that are associated with a white coat effect. These limitations can be overcome by using an oscillometric sphygmomanometer that automatically records multiple readings with the patient resting quietly and alone, called automated office (AO)BP. AOBP produces office readings with a reduced white coat effect, which are also similar to the awake ambulatory BP. There is also evidence that AOBP is a better predictor of target organ damage than attended office BP. Furthermore, clinical outcome data support AOBP as having both a similar diagnostic threshold as awake ambulatory BP and a lower treatment target. Using AOBP in clinical practice simplifies recording office BP by not requiring an additional period of rest before activation of the device and by not having staff present during the actual measurements. Recent studies have reported that automatic BP measurements taken by staff in research studies with close adherence to guidelines using AOBP devices may produce similar readings to AOBP. Further research is needed to determine the best method for recording BP at systolic targets <130mm Hg and the relationship of office BP to ambulatory BP and home BP.
引用
收藏
页码:1104 / 1107
页数:4
相关论文
共 24 条
[1]   Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device [J].
Al-Karkhi, Isam ;
Al-Rubaiy, Raad ;
Rosenqvist, Ulf ;
Falk, Magnus ;
Nystrom, Fredrik H. .
BLOOD PRESSURE MONITORING, 2015, 20 (02) :98-103
[2]   Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index [J].
Andreadis, Emmanuel A. ;
Agaliotis, Gerasimos D. ;
Angelopoulos, Epameinondas T. ;
Tsakanikas, Athanasios P. ;
Chaveles, Loannis A. ;
Mousoulis, George P. .
AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) :661-666
[3]  
[Anonymous], 2011, BMJ BRIT MED J, DOI DOI 10.1136/BMJ.D442
[4]   Automated office blood pressure - being alone and not location is what matters most [J].
Armstrong, David ;
Matangi, Murray ;
Brouillard, Daniel ;
Myers, Martin G. .
BLOOD PRESSURE MONITORING, 2015, 20 (04) :204-208
[5]   Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting [J].
Bauer, Frederic ;
Seibert, Felix S. ;
Rohn, Benjamin ;
Bauer, Klaus A. R. ;
Rolshoven, Eckart ;
Babel, Nina ;
Westhoff, Timm H. .
HYPERTENSION, 2018, 71 (02) :243-249
[6]   The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension [J].
Beckett L. ;
Godwin M. .
BMC Cardiovascular Disorders, 5 (1)
[7]   Automated oscillometric blood pressure versus auscultatory blood pressure as a predictor of carotid intima-medial thickness in male firefighters [J].
Campbell, N. R. C. ;
McKay, D. W. ;
Conradson, H. ;
Lonn, E. ;
Title, L. M. ;
Anderson, T. .
JOURNAL OF HUMAN HYPERTENSION, 2007, 21 (07) :588-590
[8]  
Chambers Larry W, 2013, CMAJ Open, V1, pE37, DOI 10.9778/cmajo.20130005
[9]   Ambulatory blood pressure in hypertensive patients with inclusion criteria for the SPRINT trial [J].
de la Sierra, Alejandro ;
Banegas, Jose R. ;
Divison, Juan A. ;
Gorostidi, Manuel ;
Vinyoles, Ernest ;
de la Cruz, Juan J. ;
Segura, Julian ;
Ruilope, Luis M. .
JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2016, 10 (12) :947-953
[10]   Blood Pressure Measurement in SPRINT (Systolic Blood Pressure Intervention Trial) [J].
Johnson, Karen C. ;
Whelton, Paul K. ;
Cushman, William C. ;
Cutler, Jeffrey A. ;
Evans, Gregory W. ;
Snyder, Joni K. ;
Ambrosius, Walter T. ;
Beddhu, Srinivasan ;
Cheung, Alfred K. ;
Fine, Lawrence J. ;
Lewis, Cora E. ;
Rahman, Mahboob ;
Reboussin, David M. ;
Rocco, Michael V. ;
Oparil, Suzanne ;
Wright, Jackson T., Jr. .
HYPERTENSION, 2018, 71 (05) :848-+