A novel water-tree detection method for XLPE power cable - Stepwise AC residual charge method

被引:0
|
作者
Ohki, Y
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:54 / 55
页数:2
相关论文
共 50 条
  • [1] Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable
    Ebinuma, Yasumitsu
    Masui, Noriaki
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2006, 7 (05) : 224 - 229
  • [2] New residual-charge measurement for water-tree deteriorated power cable
    Kon, H
    Wantanabe, K
    Miyajima, K
    Uchida, K
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 77 - 82
  • [3] Power frequency breakdown characteristics of water-tree retardant XLPE power cable
    Yan, Meng-Kun
    Luo, Jun-Hua
    Yang, Li-Ming
    Zheng, Chuan-Bao
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (10): : 2395 - 2400
  • [4] Water Tree Deterioration Diagnosis for 10 kV XLPE cable based on Residual Charge Method
    Du, B. X.
    Huo, Z. X.
    Li, H. B.
    Gao, Y.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 417 - 420
  • [5] Correlation between space charge distribution and water-tree location in aged XLPE cable
    Suzuki, K
    Tanaka, Y
    Takada, T
    Ohki, Y
    Takeya, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (01) : 78 - 81
  • [6] Study on Charge Dynamics in Water-Tree XLPE Insulation for Deterioration Diagnosis
    Ra, Nhet
    Futami, Hiroyuki
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 343 - 346
  • [7] Fundamental study on diagnostic method of water tree degraded XLPE cables using residual charge detection with pulse voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Kim, Myong Hwan
    Hozumi, Naohiro
    Tsuji, Taizo
    Miyajima, Kazuhisa
    Uchida, Katsumi
    IEEJ Transactions on Power and Energy, 2014, 134 (08) : 648 - 658
  • [8] Fundamental Study on Residual Charge Detection with Pulse Voltages as Diagnostic Method of Water Tree-Degraded XLPE Cables
    Kurihara, Takashi
    Okamoto, Tatsuki
    Tsuji, Taizo
    Uchida, Katsumi
    Kim, Myong Hwan
    Hozumi, Naohiro
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 84 - 87
  • [9] Study on Short Time Charge Behavior in Pulsed Residual Charge Method for Water Tree Diagnostics of XLPE Cables
    Futami, Hiroyuki
    Ra, Nhet
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 559 - 562
  • [10] High frequency characteristics of water-tree degraded XLPE insulation in power cables
    Mugala, Gavita
    Eriksson, Roland
    Pettersson, Per
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (05) : 1271 - 1277