Symmetric sensor for applanation resonance tomometry of the eye

被引:7
作者
Hallberg, Per [1 ]
Linden, Christina
Backlund, Tomas
Eklund, Anders
机构
[1] Umea Univ Hosp, Dept Biomed Engn & Informat, S-90185 Umea, Sweden
[2] Umea Univ, Dept Clin Sci Ophthalmol, S-90187 Umea, Sweden
[3] Umea Univ, Dept Appl Phys & Elect, S-90187 Umea, Sweden
[4] Umea Univ, Ctr Biomed Engn & Phys, S-90187 Umea, Sweden
关键词
intraocular pressure; resonance sensor; applanation; eye; tonometry; glaucoma;
D O I
10.1007/s11517-005-0005-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Applanation resonance tonometry ( ART) has been shown in a number of studies to be useful for measuring intraocular pressure (IOP). Data from in vitro laboratory bench testing, where the sensor was carefully centralised onto the cornea, has been very consistent with good precision in the determination of IOP. However, in a clinical study the unavoidable off-centre placement of the sensor against the cornea resulted in a reduced precision. The aim of this study was to evaluate a new design of the sensor with a symmetric sensor probe and a contact piece with a larger diameter. Two in vitro porcine eye experimental set-ups were used. One bench-based for examining position dependence and one biomicroscope-based set-up, simulating a clinical setting, for evaluating IOPART precision at seven different pressure levels (10-40 mmHg), set by connecting a saline column to the vitreous chamber. The reference IOP was recorded using a pressure transducer. There was no significant difference between four positions 1 mm off centre and the one centre position. The precision of the ART as compared with the reference pressure was +/- 1.03 mmHg (SD, n = 42). The design improvement has enhanced the precision of the ART in the biomicroscope set-up to be in parity with bench test results from a set-up using perfect positioning. This indicates that off-centre positioning was no longer a major contributor to the deviations in measured IOP. The precision was well within the limits set by ISO standard for eye tonometers. Therefore, a larger in vivo study on human eyes with the ART should be performed.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 15 条
[1]   Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer [J].
Bafa, M ;
Lambrinakis, I ;
Dayan, M ;
Birch, M .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (01) :15-18
[2]   Tonometry in adults and children -: A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo [J].
Eisenberg, DL ;
Sherman, BG ;
McKeown, CA ;
Schuman, JS .
OPHTHALMOLOGY, 1998, 105 (07) :1173-1181
[3]   An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement [J].
Eklund, A ;
Hallberg, P ;
Lindén, C ;
Lindahl, OA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) :3017-3024
[4]   Evaluation of applanation resonator sensors for intra-ocular pressure measurement:: results from clinical and in vitro studies [J].
Eklund, A ;
Lindén, C ;
Bäcklund, T ;
Andersson, BM ;
Lindahl, OA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (02) :190-197
[5]   A resonator sensor for measurement of intraocular pressure -: evaluation in an in vitro pig-eye model [J].
Eklund, A ;
Bäcklund, T ;
Lindahl, OA .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (03) :355-367
[6]  
EKLUND A, 1999, 11 NORD BALT C BIOM, V37, P181
[7]  
Goldmann H, 1957, GLAUCOMA, P167
[8]   Applanation resonance tonometry for intraocular pressure in humans [J].
Hallberg, P ;
Lindén, C ;
Lindahl, OA ;
Bäcklund, T ;
Eklund, A .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) :1053-1065
[9]  
HALLBERG P, 2005, IN PRESS J MED ENG T
[10]   Reduction of intraocular pressure and glaucoma progression - Results from the early manifest glaucoma trial [J].
Heijl, A ;
Leske, MC ;
Bengtsson, B ;
Hyman, L ;
Bengtsson, B ;
Hussein, M .
ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (10) :1268-1279