Standardisation and application of the single-breath determination of nitric oxide uptake in the lung

被引:112
作者
Zavorsky, Gerald S. [1 ]
Hsia, Connie C. W. [2 ]
Hughes, J. Michael B. [3 ]
Borland, Colin D. R. [4 ]
Guenard, Herve [5 ,6 ]
van der Lee, Ivo [7 ]
Steenbruggen, Irene [8 ]
Naeije, Robert [9 ]
Cao, Jiguo [10 ]
Anh Tuan Dinh-Xuan [11 ]
机构
[1] Georgia State Univ, Dept Resp Therapy, Atlanta, GA 30303 USA
[2] Univ Texas Dallas, Southwestern Med Ctr, Dept Internal Med, Dallas, TX USA
[3] Natl Heart & Lung Inst, Imperial Coll, London, England
[4] Univ Cambridge, Hinchingbrooke Hosp, Dept Med, Huntingdon, England
[5] CHU, Dept Pulm, Bordeaux, France
[6] Univ Bordeaux, Pulm Lab, Bordeaux, France
[7] Spaarne Hosp, Dept Pulm Dis, Hoofddorp, Netherlands
[8] Isala Hosp, Pulm Lab, Zwolle, Netherlands
[9] Erasme Univ Hosp, Dept Cardiol, Brussels, Belgium
[10] Simon Fraser Univ, Dept Stat & Actuarial Sci, Burnaby, BC, Canada
[11] Paris Descartes Univ, Cochin Hosp, Dept Physiol, Paris, France
关键词
PULMONARY DIFFUSING-CAPACITY; CAPILLARY BLOOD-VOLUME; SHORT-TERM VARIABILITY; CARBON-MONOXIDE; MEMBRANE-DIFFUSION; REFERENCE VALUES; GAS-EXCHANGE; DIURNAL-VARIATION; ALVEOLAR VOLUME; CARDIAC-OUTPUT;
D O I
10.1183/13993003.00962-2016
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Diffusing capacity of the lung for nitric oxide (DLNO), otherwise known as the transfer factor, was first measured in 1983. This document standardises the technique and application of single-breath DLNO. This panel agrees that 1) pulmonary function systems should allow for mixing and measurement of both nitric oxide (NO) and carbon monoxide (CO) gases directly from an inspiratory reservoir just before use, with expired concentrations measured from an alveolar "collection" or continuously sampled via rapid gas analysers; 2) breath-hold time should be 10 s with chemiluminescence NO analysers, or 4-6 s to accommodate the smaller detection range of the NO electrochemical cell; 3) inspired NO and oxygen concentrations should be 40-60 ppm and close to 21%, respectively; 4) the alveolar oxygen tension (PAO(2)) should be measured by sampling the expired gas; 5) a finite specific conductance in the blood for NO (theta NO) should be assumed as 4.5 mL.min(-1) . mmHg(-1) . mL(-1) of blood; 6) the equation for 1/theta CO should be (0.0062 . PAO(2)+1.16) . (ideal haemoglobin/measured haemoglobin) based on breath-holding PAO(2) and adjusted to an average haemoglobin concentration (male 14.6 g.dL(-1), female 13.4 g.dL(-1)); 7) a membrane diffusing capacity ratio (DMNO/DMCO) should be 1.97, based on tissue diffusivity.
引用
收藏
页数:23
相关论文
共 114 条
[1]   European reference equations for CO and NO lung transfer [J].
Aguilaniu, B. ;
Maitre, J. ;
Gienet, S. ;
Gegout-Petit, A. ;
Guenard, H. .
EUROPEAN RESPIRATORY JOURNAL, 2008, 31 (05) :1091-1097
[2]   Nasal nitric oxide in a random sample of adults and its relationship to sensitization, cat allergen, rhinitis, and ambient nitric oxide [J].
Alexanderson, Cecilia ;
Olin, Anna-Carin ;
Dahlman-Hoglund, Anna ;
Finizia, Caterina ;
Toren, Kjell .
AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2012, 26 (03) :E99-E103
[3]   Inhaled nitric oxide alters the distribution of blood flow in the healthy human lung, suggesting active hypoxic pulmonary vasoconstriction in normoxia [J].
Asadi, Amran K. ;
Sa, Rui Carlos ;
Kim, Nick H. ;
Theilmann, Rebecca J. ;
Hopkins, Susan R. ;
Buxton, Richard B. ;
Prisk, G. Kim .
JOURNAL OF APPLIED PHYSIOLOGY, 2015, 118 (03) :331-343
[4]   Mechanisms of Slower Nitric Oxide Uptake by Red Blood Cells and Other Hemoglobin-containing Vesicles [J].
Azarov, Ivan ;
Liu, Chen ;
Reynolds, Hannah ;
Tsekouras, Zaharo ;
Lee, Janet S. ;
Gladwin, Mark T. ;
Kim-Shapiro, Daniel B. .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2011, 286 (38) :33567-33579
[5]   Mechanisms for reduced pulmonary diffusing capacity in haematopoietic stem-cell transplantation recipients [J].
Barisione, Giovanni ;
Bacigalupo, Andrea ;
Brusasco, Claudia ;
Scanarotti, Chiara ;
Penco, Susanna ;
Bassi, Anna Maria ;
Lamparelli, Teresa ;
Garlaschi, Alessandro ;
Pellegrino, Riccardo ;
Brusasco, Vito .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2014, 194 :54-61
[6]  
Borland C, 1985, Tokai J Exp Clin Med, V10, P371
[7]   Can a membrane oxygenator be a model for lung NO and CO transfer? [J].
Borland, C ;
Dunningham, H ;
Bottrill, F ;
Vuylsteke, A .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (05) :1527-1538
[8]   MEASUREMENT OF EXHALED NITRIC-OXIDE IN MAN [J].
BORLAND, C ;
COX, Y ;
HIGENBOTTAM, T .
THORAX, 1993, 48 (11) :1160-1162
[9]  
BORLAND C, 1983, CLIN SCI, V65, pP37
[10]   Steady-state measurement of NO and CO lung diffusing capacity on moderate exercise in men [J].
Borland, C ;
Mist, B ;
Zammit, M ;
Vuylsteke, A .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (02) :538-544