Performance of a fast response miniature Adiabatic Demagnetisation Refrigerator using a single crystal tungsten magnetoresistive heat switch

被引:18
作者
Bartlett, J. [1 ]
Hardy, G. [1 ]
Hepburn, I. D. [1 ]
机构
[1] Univ Coll London, Mullard Space Sci Lab, Dept Space & Climate Phys, Dorking RH5 6NT, Surrey, England
基金
英国工程与自然科学研究理事会;
关键词
Magnetic cooling; Tungsten heat switch; Magnetoresistivity; Continuous cooling; Millikelvin cryocooler;
D O I
10.1016/j.cryogenics.2015.10.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a fast thermal response miniature Adiabatic Demagnetisation Refrigerator (ADR) is presented. The miniature ADR is comprised of a fast thermal response Chromium Potassium Alum (CPA) salt pill, two superconducting magnets and unconventionally, a single crystal tungsten magnetoresistive (MR) heat switch. The development of this ADR is a result of the ongoing development of a continuously operating millikelvin cryocooler (mKCC), which will use only magnetoresistive heat switches. The design and performance of the MR heat switch developed for the mKCC and used in the miniature ADR is presented in this paper; the heat switch has a measured Residual Resistivity Ratio of 32,000 +/- 3000 and an estimated switching ratio (on thermal conductivity divided by the off thermal conductivity) of 15,200 at 3.6 K and 38,800 at 0.2 K when using a 3 T magnetic field. The performance of the miniature ADR operating from a 3.6 K bath is presented, demonstrating that a complete cycle (magnetisation, cooling to the bath and demagnetisation) can be accomplished in 82 s. A magnet current step test, conducted when the ADR is cold and fully demagnetised, has shown the thermal response of the ADR to be sub-second. The measured hold times of the ADR with just parasitic heat load are given, ranging from 3 min at 0.2 K with 13.14 mu W of parasitics, to 924 min at 3 K with 4.55 mu W of parasitics. The cooling power has been measured for operating temperatures in the range 0.25-3 K by applying an additional heat load to the ADR via a heater, in order to reduce the hold time to 3 min (i.e. approximately double the recycle time); the maximum cooling power of the miniature ADR (in addition to parasitic load) when operating at 250 mK is 20 mu W, which increases to 45 mu W at 300 mK and continues to increase linearly to nearly 1.1 mW at 3 K. To conclude, the predicted performance of a tandem continuous ADR utilising two of the miniature ADRs is presented. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:111 / 121
页数:11
相关论文
共 11 条
  • [1] Design and performance of a fast thermal response miniature Chromium Potassium Alum (CPA) salt pill for use in a millikelvin cryocooler
    Bartlett, J.
    Hardy, G.
    Hepburn, I. D.
    [J]. CRYOGENICS, 2015, 65 : 26 - 37
  • [2] Millikelvin cryocooler for space and ground based detector systems
    Bartlett, J.
    Hardy, G.
    Hepburn, I.
    Milward, S.
    Coker, P.
    Theobald, C.
    [J]. MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [3] Thermal characterisation of a tungsten magnetoresistive heat switch
    Bartlett, J.
    Hardy, G.
    Hepburn, I.
    Ray, R.
    Weatherstone, S.
    [J]. CRYOGENICS, 2010, 50 (09) : 647 - 652
  • [4] Improved performance of an engineering model cryogen free double adiabatic demagnetization refrigerator
    Bartlett, J.
    Hardy, G.
    Hepburn, I. D.
    Brockley-Blatt, C.
    Coker, P.
    Crofts, E.
    Winter, B.
    Milward, S.
    Stafford-Allen, R.
    Brownhill, M.
    Reed, J.
    Linder, M.
    Rando, N.
    [J]. CRYOGENICS, 2010, 50 (09) : 582 - 590
  • [5] Bartlett J, 2008, THESIS
  • [6] Batdalov A. B., 1980, Soviet Physics - Solid State, V22, P664
  • [7] Canavan ER, 2002, AIP CONF PROC, V613, P1183, DOI 10.1063/1.1472144
  • [8] Duval JM, 2004, CRYOCOOLERS, V13, P567
  • [9] Thermal Magnetoconductivity of Tungsten Below 6 K: Combining the Zero-, Low- and High-Field Cases
    Hills, M. J.
    Hepburn, I. D.
    Bartlett, J.
    Hardy, G.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2015, 178 (1-2) : 18 - 34
  • [10] HEAT SWITCHES PROVIDING LOW-ACTIVATION POWER AND QUICK-SWITCHING TIME FOR USE IN CRYOGENIC MULTI-STAGE REFRIGERATORS
    Kimball, Mark O.