Non-invasive blood pressure monitoring with an oscillometric brachial cuff: impact of arrhythmia

被引:12
作者
Lakhal, Karim [1 ]
Martin, Maelle [1 ]
Ehrmann, Stephan [2 ,3 ]
Faiz, Sofian [4 ]
Rozec, Bertrand [1 ]
Boulain, Thierry [4 ]
机构
[1] Ctr Hosp Univ, Hop Laennec, Serv Anesthesie Reanimat, Reanimat Chirurg Polyvalente, Blvd Jacques Monod, F-44093 Nantes, France
[2] CHRU Tours, Med Intens Reanimat, F-37044 Tours, France
[3] Univ Tours, Ctr Etude Pathol Resp, Aerosoltherapie & Biomed Visee Resp, INSERM,UMR,Fac Med, F-37032 Tours, France
[4] Ctr Hosp Reg, Hop La Source, Serv Reanimat Med, F-45067 Orleans, France
关键词
Atrial fibrillation (MeSH); Blood pressure determination (MeSH); Intensive care units (MeSH); Oscillometry; Sphygmomanometer; ATRIAL-FIBRILLATION; EUROPEAN-SOCIETY; RECOMMENDATIONS; ASSOCIATION; GUIDELINES; AGREEMENT; HOME;
D O I
10.1007/s10877-017-0067-2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Arrhythmia-induced beat-to-beat variability of blood pressure (BP) is deemed to hinder the reliability of non-invasive oscillometric measurements (NIBP) but few data support this belief. We assessed the impact of arrhythmia on a NIBP device never tested for this purpose. We compared, in intensive care unit patients with and without arrhythmia, the agreement between three pairs of NIBP (Infinity (TM) Delta monitor, Drager medical systems) and invasive readings. For systolic, diastolic and mean BP, the mean bias between NIBP and invasive measurements was not higher, in 89 patients with arrhythmia, than that observed in 127 patients with regular rhythm (p = 0.93 for mean BP). Averaging three measurements overcame the higher within-subject variability of NIBP measurements during arrhythmia, and yielded similar agreement between the two techniques in patients with arrhythmia and with regular rhythm. The international organization for standardization criteria (mean bias < 5 and SD < 8 mmHg) were satisfied neither during arrhythmia nor during regular rhythm: for mean BP, mean bias of - 8.0 +/- 6.5 and - 7.5 +/- 6.1 mmHg, respectively. The detection of hypotension (systolic invasive BP < 90 mmHg or mean invasive BP < 65 mmHg) or hypertension (systolic invasive BP > 140 mmHg) by NIBP was similar during arrhythmia and regular rhythm [areas under the receiver operating characteristic curves (AUC(ROC)) of 0.88-0.92, p > 0.13]. The detection of a 10% increase in mean invasive BP after cardiovascular intervention was also associated with similar AUC(ROC)s between the two groups. Provided that triplicates are averaged, the agreement between NIBP measured with the tested device and invasive measurements was not worse during arrhythmia than during regular rhythm.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 26 条
[1]   A review of the latest guidelines for NIBP device validation [J].
Alpert, Bruce S. ;
Quinn, David E. ;
Friedman, Bruce A. .
BLOOD PRESSURE MONITORING, 2013, 18 (06) :297-302
[2]   Incidence and prognosis of sustained Arrhythmias in critically ill patients [J].
Annane, Djillali ;
Sebille, Veronique ;
Duboc, Denis ;
Le Heuzey, Jean-Yves ;
Sadoul, Nicolas ;
Bouvier, Erik ;
Bellissant, Eric .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 178 (01) :20-25
[3]   Intensive Care Medicine and the "Cenacle principles" [J].
Antonelli, Massimo .
INTENSIVE CARE MEDICINE, 2007, 33 (04) :567-569
[4]   Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive? [J].
Araghi, Ali ;
Bander, Joseph J. ;
Guzman, Jorge A. .
CRITICAL CARE, 2006, 10 (02)
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine [J].
Cecconi, Maurizio ;
De Backer, Daniel ;
Antonelli, Massimo ;
Beale, Richard ;
Bakker, Jan ;
Hofer, Christoph ;
Jaeschke, Roman ;
Mebazaa, Alexandre ;
Pinsky, Michael R. ;
Teboul, Jean Louis ;
Vincent, Jean Louis ;
Rhodes, Andrew .
INTENSIVE CARE MEDICINE, 2014, 40 (12) :1795-1815
[7]   Results of a survey of blood pressure monitoring by intensivists in critically ill patients: A preliminary study [J].
Chatterjee, Arjun ;
DePriest, Kirk ;
Blair, Russell ;
Bowton, David ;
Chin, Robert .
CRITICAL CARE MEDICINE, 2010, 38 (12) :2335-2338
[8]   Is the Standard Supplied by the Association for the Advancement of Medical Instrumentation the Measure of All Things for Noninvasive Continuous Hemodynamic Devices? [J].
Fortin, Juergen ;
Lerche, Katja ;
Flot-zinger, Doris ;
O'Brien, Terence .
ANESTHESIOLOGY, 2015, 122 (01) :208-209
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]  
International Organization for Standardization (ISO), 2013, 8106022013 ISO