Detection of anti-EPO antibodies in human sera by a bridging ELISA is much more sensitive when coating biotinylated rhEPO to streptavidin rather than using direct coating of rhEPO

被引:26
作者
Gross, Johann
Moller, Renate
Henke, Wolfgang
Hoesel, Wolfgang
机构
[1] Roche Diagnos GmbH, D-82372 Penzberg, Germany
[2] Humboldt Univ, Charite Hosp, Dept Otorhinolaryngol, Mol Biol Res Lab, D-14050 Berlin, Germany
关键词
recombinant human erythropoietin (rhEPO); anti-erythropoietin antibody ELISA; direct coating; streptavidin/biotin coupling;
D O I
10.1016/j.jim.2006.04.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sensitive and efficient methods for detecting anti-erythropoietin (anti-EPO) antibodies are needed for analysis and, above all, for large scale screening of human serum samples. ELISA is an attractive alternative to labor-intensive radioimmuno-precipitation assays but apparently conflicting reports question its sensitivity. We sought to resolve this issue by directly comparing different reported ELISA approaches to determine whether rhEPO-coating methods affect detection of anti-EPO antibodies. Investigators reporting low sensitivity had used ELISAs in which rhEPO was directly coated to microliter plates while the high sensitivity ELISA used plate-bound streptavidin to bind biotinylated rhEPO. Using anti-EPO positive human sera, our results confirmed a large (100- to 300-fold) difference in sensitivity between the ELISAs and suggested that the inferiority of the low sensitivity ELISA was caused by the direct coating of rhEPO which may disrupt epitopes by masking recognition sites or introducing conformational changes. Thus, a bridging ELISA can be an appropriate and effective system for antibody analysis and screening of human sera with high sensitivity and specificity but only if performed with streptavidin binding of biotinylated antigen. This finding may also be more generally applicable to the detection of antibodies against other protein antigens. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 12 条
[1]   ELISA methods for the analysis of antibody responses induced in multiple sclerosis patients treated with recombinant interferon-β [J].
Brickelmaier, M ;
Hochman, PS ;
Baciu, R ;
Chao, B ;
Cuervo, JH ;
Whitty, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :121-135
[2]   THE PHYSICAL AND FUNCTIONAL-BEHAVIOR OF CAPTURE ANTIBODIES ADSORBED ON POLYSTYRENE [J].
BUTLER, JE ;
NI, L ;
NESSLER, R ;
JOSHI, KS ;
SUTER, M ;
ROSENBERG, B ;
CHANG, J ;
BROWN, WR ;
CANTARERO, LA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) :77-90
[3]   Solid supports in enzyme-linked immunosorbent assay and other solid-phase immunoassays [J].
Butler, JE .
METHODS-A COMPANION TO METHODS IN ENZYMOLOGY, 2000, 22 (01) :4-23
[4]   Recommendations on haematological criteria for the diagnosis of epoetin-induced pure red cell aplasia [J].
Casadevall, N ;
Cournoyer, D ;
Marsh, J ;
Messner, H ;
Pallister, C ;
Parker-Williams, J ;
Rossert, J .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2004, 73 (06) :389-396
[5]   Pure red-cell aplasia and antierythropoietin antibodies in patients treated with recombinant erythropoietin. [J].
Casadevall, N ;
Nataf, J ;
Viron, B ;
Kolta, A ;
Kiladjian, J ;
Martin-Dupont, P ;
Michaud, P ;
Papo, T ;
Ugo, V ;
Teyssandier, I ;
Varet, B ;
Mayeux, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (07) :469-475
[6]   Brief report: Autoantibodies against erythropoietin in a patient with pure red-cell aplasia [J].
Casadevall, N ;
Dupuy, E ;
MolhoSabatier, P ;
Tobelem, G ;
Varet, B ;
Mayeux, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (10) :630-633
[7]   Development and evaluation of a new ELISA for the detection and quantification of antierythropoietin antibodies in human sera [J].
Hoesel, W ;
Gross, J ;
Moller, R ;
Kanne, B ;
Wessner, A ;
Müller, G ;
Müller, A ;
Gromnica-Ihle, E ;
Fromme, A ;
Bischoff, S ;
Haselbeck, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 294 (1-2) :101-110
[8]   Erythropoiesis-stimulating agents and antibody-mediated pure red-cell aplasia:: where are we now and where do we go from here? [J].
Locatelli, F ;
Aljama, P ;
Barany, P ;
Canaud, B ;
Carrera, F ;
Eckardt, KU ;
Macdougall, IC ;
Macleod, A ;
Hörl, WH ;
Wiecek, A ;
Cameron, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (02) :288-293
[9]  
Swanson S J, 2003, Dev Biol (Basel), V112, P127
[10]   Evaluation of methods to detect and characterize antibodies against recombinant human erythropoietin [J].
Swanson, SJ ;
Ferbas, J ;
Mayeux, P ;
Casadevall, N .
NEPHRON CLINICAL PRACTICE, 2004, 96 (03) :88-95