PAH and PCB removal efficiencies in Umea (Sweden) and Siauliai (Lithuania) municipal wastewater treatment plants

被引:39
作者
Bergqvist, P. -A. [1 ]
Augulyte, L.
Jurjoniene, V.
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
[2] Kaunas Univ Technol, Dept Environm Engn, Fac Chem Technol, LT-50254 Kaunas, Lithuania
[3] Kaunas Univ Technol, Dept Environm Engn, Fac Chem Technol, LT-50254 Kaunas, Lithuania
关键词
analysis; bioavailable fraction; diffusive sampling; effluent; PAHs; PCBs; SPMDs; wastewater treatment efficiency; SEMIPERMEABLE-MEMBRANE DEVICES; POLYCYCLIC AROMATIC-HYDROCARBONS; SEWAGE-TREATMENT PLANT; SPMDS; EFFLUENTS; IDENTIFICATION; POLLUTANTS; SEDIMENTS; TOXICITY; SLUDGE;
D O I
10.1007/s11270-006-9139-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dissolved concentrations of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) in the influents and effluents of two municipal sewage treatment plants (STPs) were monitored over 16- (Umea, Sweden) and 22- (Saiauliai, Lithuania) day sampling periods. Sampling was performed using a passive sampling technique (semipermeable membrane devices; SPMDs) for sequestration of the dissolved (readily bioavailable) fraction of persistent organic pollutants (POPs). Removal efficiencies for individual low molecular weight (LMW) PAH compounds varied from 84% to levels at which the compounds were not detected in effluents from Umea. The corresponding efficiencies of the Saiauliai plant were 33-95%. Measurements revealed that dissolved concentrations of most of the PCBs and some of the high molecular weight (HMW) PAHs increased during the conventional wastewater treatment at both plants. The release of dissolved PAHs and PCBs in the effluents from municipal wastewater treatment plants might increase the environmental contamination by readily bioavailable pollutants in the recipient waters; the rivers Umealven and Kulpe. SPMDs were found to be suitable sampling tools for long-term (weeks-month) integrative monitoring of trace concentrations of the dissolved fraction of hydrophobic pollutants in the wastewater process, since the sampling and clean-up steps were easy to perform.
引用
收藏
页码:291 / 303
页数:13
相关论文
共 24 条
[1]   Identification of organic compounds and ecotoxicological assessment of sewage treatment plants (STP) effluents [J].
Aguayo, S ;
Muñoz, MJ ;
de la Torre, A ;
Roset, J ;
de la Peña, E ;
Carballo, M .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 328 (1-3) :69-81
[2]   Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs) [J].
Bartkow, ME ;
Huckins, JN ;
Müller, JF .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (35) :5983-5990
[3]   Polychlorinated biphenyls and hexachlorobenzene in atmosphere, sea-surface microlayer, and water measured with semi-permeable membrane devices (SPMDs) [J].
Booij, K ;
van Drooge, BL .
CHEMOSPHERE, 2001, 44 (02) :91-98
[4]  
BRISTAV B, 2002, ENV REPORT ONS MWWTP
[5]  
*EUR COMM, 1991, CONC URB WAST TREATM
[6]  
Huckins J.N. P., 2002, A Guide for the Use of Semipermeable Membrane Devices (SPMDs) as Samplers of Waterborne Hydrophobic Organic Contaminants: Report for the American Petroleum Institute (API)
[7]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[8]   Determination of polycyclic aromatic hydrocarbons in wastewater, sediments, sludge and plants in Karak Province, Jordan [J].
Jiries, A ;
Hussain, H ;
Lintelmann, J .
WATER AIR AND SOIL POLLUTION, 2000, 121 (1-4) :217-228
[9]  
LIU D.H.F., 1997, Environmental Engineer's Handbook, Vsecond
[10]  
Lundstedt S., 2003, Doctoral dissertation, Kemi