Dual-frequency IVUS array for contrast enhanced intravascular ultrasound imaging

被引:0
|
作者
Wang, Zhuochen [1 ]
Huang, Wenbin [1 ]
Jiang, Xiaoning [1 ]
Martin, K. Heath [2 ]
Dayton, Paul A. [2 ]
机构
[1] N Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[2] Joint Dept Biomed Engn Univ North Carolina Chapel, Chapel Hill, NC USA
关键词
dual frequency ultrasound; transducer array; lateral mode transducer; superharmonic; CE-IVUS; microbubble; ACOUSTIC ANGIOGRAPHY; TRANSDUCERS; ANGIOGENESIS; PROGRESSION; RESOLUTION; DESIGN;
D O I
10.1109/ULTSYM.2015.0545
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent studies suggest that contrast enhanced intravascular ultrasound (CE-IVUS) may be used for identifying vulnerable plaques through molecular imaging or detecting neovascularizations within a growing atherosclerotic lesion. However, typical intravascular ultrasound (IVUS) transducers operate at a high frequency band (20-60 MHz) which makes them not ideal for imaging microbubble contrast agents due to the less effective microbubble excitation at high frequencies. In this paper, a prototyped dual-frequency array for CE-IVUS was developed and tested. The prototype flat transducer array consists of a receiving array (32 elements, 30 MHz) built on the top of a transmitting array (8 sub-elements, 2.25 MHz) to achieve real-time superharmonic contrast enhanced imaging. The size of the receiving aperture was varied, tested and resultant images were compared. Images of a contrast-filled microtube can be observed clearly with only 4 receiving elements at an excitation voltage of 55 V, which indicates feasibility of CE-IVUS imaging after circularly wrapping the array for catheter integration.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Ma, Jianguo
    Jiang, Xiaoning
    Martin, Karl Heath
    Dayton, Paul A.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2104 - 2107
  • [2] A DUAL FREQUENCY IVUS TRANSDUCER WITH A LATERAL MODE TRANSMITTER FOR CONTRAST ENHANCED INTRAVASCULAR ULTRASOUND IMAGING
    Wang, Zhuochen
    Martin, K. Heath
    Dayton, Paul A.
    Jiang, Xiaoning
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 3, 2016,
  • [3] Micromachined 1-3 Composite Dual Frequency IVUS Array for Contrast Enhanced Intravascular Ultasound Imaging
    Wu, Huaiyu
    Li, Sibo
    Jiang, Xiaoning
    Kasoji, Sunny
    Dayton, Paul A.
    Tian, Jian
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging
    Martin, K. Heath
    Lindsey, Brooks D.
    Ma, Jianguo
    Lee, Mike
    Li, Sibo
    Foster, F. Stuart
    Jiang, Xiaoning
    Dayton, Paul A.
    SENSORS, 2014, 14 (11) : 20825 - 20842
  • [5] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, ME
    Goertz, DE
    Vos, HJ
    Droog, E
    Blacquière, G
    Gisolf, A
    van der Steen, AFW
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 241 - 244
  • [6] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, Martijn E.
    Goertz, David E.
    Vos, Hendrik J.
    Tesselaar, Erik
    Blacquiere, Gerrit
    Gisolf, Andries
    Krams, Rob
    van der Steen, Antonius F. W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11): : 1649 - 1654
  • [7] Dual-frequency intravascular ultrasound imaging of microbubble contrast agents: Ex vivo and in vivo demonstration
    Lindsey, Brooks D.
    Martin, K. Heath
    Dayton, Paul A.
    Ma, Jianguo
    Wang, Zhuochen
    Jiang, Xiaoning
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [8] A novel dual-frequency imaging method for intravascular ultrasound applications
    Qiu, Weibao
    Chen, Yan
    Wong, Chi-Man
    Liu, Baoqiang
    Dai, Jiyan
    Zheng, Hairong
    ULTRASONICS, 2015, 57 : 31 - 35
  • [9] Dual-frequency intravascular ultrasound imaging: A novel approach to plaque vulnerability
    Hashimoto, G
    Hiro, T
    Fujii, T
    Okamura, T
    Yamada, J
    Fukumoto, Y
    Kanou, H
    Matsuzaki, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 120A - 121A
  • [10] Multi-Frequency Intravascular Ultrasound (IVUS) Imaging
    Ma, Teng
    Yu, Mingyue
    Chen, Zeyu
    Fei, Chunlong
    Shung, K. Kirk
    Zhou, Qifa
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (01) : 97 - 107