摘要
This communication reports an investigation undertaken towards setting collimation of an optical beam using a self-imaging technique and histogram error (HE) based approach. The beam under test illuminates an amplitude type Ronchi grating. After the grating, a beam splitter is placed such that the grating's self-images are formed in two perpendicular directions, at the different Talbot planes. The images are then recorded using two identical CCD cameras. Towards implementing a HE based algorithm, first, element-by-element subtraction of the normalized histogram of both self-images is computed. Next, the sum of the elements of the resultant image matrix is determined. Finally, the square of the sum yields the HE. HE provides an estimate of the collimation errors in the beam. For an incident collimated beam, the self-images recorded at different Talbot planes have identical unit magnification with respect to the grating; however, when the beam diverges or converges, the size and fringe width of self-images are differentially magnified or demagnified. Hence, when the beam is collimated, the HE is minimum. For the decollimated beam, the value of HE is higher, and increases as the decollimation errors increase. Using the proposed method, we could set the collimation position to a resolution of 1 mu m, which relates to +/- 0.22 mu radians in terms of collimation angle (for a lens of focal length 300 mm and diameter 40 mm). Experimental results conclusively establish the viability of the technique. Good accuracy and precision in the measurement have been achieved.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Improved measurement characteristics in collimation testing using Lau interferometry and Fourier fringe analysis technique
    Disawal, Reena
    Dhanotia, Jitendra
    Prakash, Shashi
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2014, 38 (04): : 948 - 955
  • [2] Automated collimation testing in Lau interferometry using phase shifting technique
    Rana, Santosh
    Prakash, Shashi
    Prakash, Satya
    OPTICS AND LASERS IN ENGINEERING, 2009, 47 (06) : 656 - 661
  • [3] Optical beam collimation procedures and collimation testing: a summary
    Sirohi, Rajpal S.
    OPTICAL ENGINEERING, 2020, 59 (04)
  • [4] Self-imaging-based laser collimation testing technique
    Mudassar, Asloob A.
    Butt, Saira
    APPLIED OPTICS, 2010, 49 (31) : 6057 - 6062
  • [5] Automated collimation testing by determining the statistical correlation coefficient of Talbot self-images
    Rana, Santosh
    Dhanotia, Jitendra
    Bhatia, Vimal
    Prakash, Shashi
    APPLIED OPTICS, 2018, 57 (10) : 2686 - 2692
  • [6] Collimation testing based on self-imaging
    Torroba, R
    Bolognini, N
    Tebaldi, M
    Tagliaferri, A
    4TH IBEROAMERICAN MEETING ON OPTICS AND 7TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, 2001, 4419 : 198 - 201
  • [7] Collimation testing using coherent gradient sensing
    Dhanotia, Jitendra
    Prakash, Shashi
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (9-10) : 1185 - 1189
  • [8] Collimation testing using slit Fresnel diffraction
    Luo, Xiaohe
    Hui, Mei
    Wang, Shanshan
    Hou, Yinlong
    Zhou, Siyu
    Zhu, Qiudong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (03)
  • [9] Collimation testing using a circular Dammann grating
    Zhao, Shual
    Chung, Po Sheun
    OPTICS COMMUNICATIONS, 2007, 279 (01) : 1 - 6
  • [10] Radial period extraction method employing frequency measurement for quantitative collimation testing
    Li, Sikun
    Wang, Xiangzhao
    OPTICS COMMUNICATIONS, 2016, 358 : 164 - 168