A novel in vivo method to evaluate trueness of digital impressions

被引:35
作者
Albdour, Emad A. [1 ,2 ,3 ]
Shaheen, Eman [1 ,2 ]
Vranckx, Myrthel [1 ,2 ]
Mangano, Francesco Guido [4 ]
Politis, Constantinus [1 ,2 ]
Jacobs, Reinhilde [1 ,2 ,5 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Oral & Maxillofacial Surg, Leuven, Belgium
[3] Jordanian Armed Forces, Dept Prosthodont, Royal Med Serv, Amman, Jordan
[4] Univ Varese, Dent Sch, Dept Med & Surg, Varese, Italy
[5] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
关键词
Intraoral scanners; Digital impression; Conventional impression; Trueness; CONVENTIONAL IMPRESSIONS; DENTAL IMPRESSIONS; ACCURACY; RESTORATIONS;
D O I
10.1186/s12903-018-0580-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Intraoral scanners are devices for capturing digital impressions in dentistry. Until now, several in vitro studies have assessed the trueness of digital impressions, but in vivo studies are missing. Therefore, the purpose of this study was to introduce a new method to assess trueness of intraoral scanners and digital impressions in an in vivo clinical set-up. Methods: A digital impression using an intraoral scanner (Trios (R) 3 Cart wired, 3-Shape, Copenhagen, Denmark) and a conventional alginate impression (Cavex Impressional*, Cavex, Haarlem, the Netherlands) as clinical reference were made for two patients assigned for full mouth extraction. A total of 30 teeth were collected upon surgery after impressions making. The gypsum model created from conventional impression and extracted teeth were then scanned in a lab scanner (Activity 885 (R), SmartOptics, Bochum, Germany). Digital model of the intraoral scanner (DM), digital model of the conventional gypsum cast (CM) and those of the extracted natural teeth (NT) were imported to a reverse engineering software (3-matic (R), Materialise, Leuven, Belgium) in which the three models were registered then DM and CM were compared to their corresponding teeth in NT by distance map calculations. Results: DM had statistically insignificant better trueness when compared to CM for total dataset (p = 0.15), statistically insignificant better trueness for CM when mandibular arches analyzed alone (p = 0.56), while a significantly better DM trueness (p = 0.013) was found when only maxillary arches were compared. Conclusions: Our results show that digital impression technique is clinically as good as or better than the current reference standard for study models of orthognathic surgery patients.
引用
收藏
页数:7
相关论文
共 30 条
[1]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[2]   Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients [J].
Boeddinghaus, Moritz ;
Breloer, Eva Sabina ;
Rehmann, Peter ;
Woestmann, Bernd .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) :2027-2034
[3]   A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a complete-arch custom tray [J].
Ceyhan, JA ;
Johnson, GH ;
Lepe, X ;
Phillips, KM .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (03) :228-234
[4]   Factors affecting the accuracy of elastometric impression materials [J].
Chen, SY ;
Liang, WM ;
Chen, FN .
JOURNAL OF DENTISTRY, 2004, 32 (08) :603-609
[5]   Comparison of accuracy and reproducibility of casts made by digital and conventional methods [J].
Cho, Seok-Hwan ;
Schaefer, Oliver ;
Thompson, Geoffrey A. ;
Guentsch, Arndt .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) :310-315
[6]   Accuracy of contacts calculated from 3D images of occlusal surfaces [J].
DeLong, R. ;
Knorr, S. ;
Anderson, G. C. ;
Hodges, J. ;
Pintado, M. R. .
JOURNAL OF DENTISTRY, 2007, 35 (06) :528-534
[7]   Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision [J].
Ender, Andreas ;
Mehl, Albert .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (86)
[8]   ACCURACY OF COMPLETE-ARCH DENTAL IMPRESSIONS: A NEW METHOD OF MEASURING TRUENESS AND PRECISION [J].
Ender, Andreas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (02) :121-128
[9]  
Endo T, 2006, QUINTESSENCE INT, V37, P47
[10]  
Fasbinder DJ, 2013, AM J DENT, V26, P115