Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics

被引:12
作者
Akil, Handan [1 ]
Dastiridou, Anna [1 ]
Marion, Kenneth [1 ]
Francis, Brian A. [1 ,2 ]
Chopra, Vikas [1 ,2 ]
机构
[1] Doheny Eye Inst, Doheny Image Reading Ctr, 1355 San Pablo St, Los Angeles, CA 90033 USA
[2] David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA
关键词
Anterior chamber angle; Anterior segment OCT; Diurnal variation; Angle metrics; SLIT-LAMP OCT; CHAMBER ANGLE; AXIAL LENGTH; INTRAOCULAR-PRESSURE; DYNAMIC-ANALYSIS; PUPIL-DILATION; TIME; FLUCTUATIONS; PARAMETERS; CLOSURE;
D O I
10.1186/s12886-017-0425-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: First reported study to assess the effect of diurnal variation on anterior chamber angle measurements, as well as, to re-test the effects of lighting and angle-of-incidence variation on anterior chamber angle (ACA) measurements acquired by time-domain anterior segment optical coherence tomography (AS-OCT). Methods: A total of 30 eyes from 15 healthy, normal subjects underwent anterior chamber imaging using a Visante time-domain AS-OCT according to an IRB-approved protocol. For each eye, the inferior angle was imaged twice in the morning (8 am - 10 am) and then again in the afternoon (3 pm - 5 pm), under light meter-controlled conditions with ambient room lighting 'ON' and lights 'OFF', and at 5 degrees angle of incidence increments. The ACA metrics measured for each eye were: angle opening distance (AOD, measured 500 and 750 mu m anterior from scleral spur), the trabecular-iris-space area (TISA, measured 500 and 750 mu m anterior from scleral spur), and scleral spur angle. Measurements were performed by masked, certified Reading Center graders using the Visante's Internal Measurement Tool. Differences in measurements between morning and afternoon, lighting variations, and angle of incidence were compared. Results: Mean age of the participants was 31.2 years (range 23-58). Anterior chamber angle metrics did not differ significantly from morning to afternoon imaging, or when the angle of incidence was offset by 5 degrees in either direction away from the inferior angle 6 o'clock position. (p-value 0.13-0.93). Angle metrics at the inferior corneal limbus, 6 o'clock position (IC270), with room lighting 'OFF', showed a significant decrease (p < 0.05) compared to room lighting 'ON'. Conclusions: There does not appear to be significant diurnal variation in AS-OCT parameters in normal individuals, but lighting conditions need to be strictly controlled since variation in lighting led to significant variability in AS-OCT parameters. No changes in ACA parameters were noted by varying the angle-of-incidence, which gives confidence in being able to perform longitudinal studies in approximately the same area (plus/ minus 5 degrees of original scan location).
引用
收藏
页数:5
相关论文
共 27 条
[1]   Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT [J].
Akil, Handan ;
Marion, Kenneth ;
Dastiridou, Anna ;
Jenkins, Dennis ;
Kramer, Brendan ;
Francis, Brian A. ;
Chopra, Vikas .
INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) :31-37
[2]   Biometric Evaluation of Anterior Chamber Changes after Physiologic Pupil Dilation Using Pentacam and Anterior Segment Optical Coherence Tomography [J].
Aptel, Florent ;
Chiquet, Christophe ;
Beccat, Sylvain ;
Denis, Philippe .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) :4005-4010
[3]   Dynamic Analysis of Iris Configuration with Anterior Segment Optical Coherence Tomography [J].
Cheung, Carol Yim-lui ;
Liu, Shu ;
Weinreb, Robert N. ;
Liu, Jing ;
Li, Haitao ;
Leung, Dexter Yu-lung ;
Dorairaj, Syril ;
Liebmann, Jeffrey ;
Ritch, Robert ;
Lam, Dennis Shun Chiu ;
Leung, Christopher Kai-shun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4040-4046
[4]   DIURNAL-VARIATION IN ONSET OF ACUTE CLOSED ANGLE GLAUCOMA [J].
CLARK, CV ;
MAPSTONE, R .
BRITISH MEDICAL JOURNAL, 1986, 292 (6528) :1106-1106
[5]   Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography [J].
Dastiridou, Anna I. ;
Pan, Xiaojing ;
Zhang, ZhouYuan ;
Marion, Kenneth M. ;
Francis, Brian A. ;
Sadda, Srinivas R. ;
Chopra, Vikas .
JOURNAL OF OPHTHALMOLOGY, 2015, 2015
[6]   Assessment of anterior chamber angle using Visante OCT, slit-lamp OCT, and Pentacam [J].
Dinc, Umut A. ;
Oncel, Banu ;
Gorgun, Ebru ;
Yalvac, Ilgaz S. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) :531-537
[7]   Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography [J].
Khor, Wei-Boon ;
Sakata, Lisandro M. ;
Friedman, David S. ;
Narayanaswamy, Arun ;
Lavanya, Raghavan ;
Perera, Shamira A. ;
Aung, Tin .
JOURNAL OF GLAUCOMA, 2010, 19 (06) :365-368
[8]   Structure-Function Relationships in Normal and Glaucomatous Eyes Determined by Time- and Spectral-Domain Optical Coherence Tomography [J].
Lee, Jong Rak ;
Jeoung, Jin Wook ;
Choi, Jaewan ;
Choi, Jin Young ;
Park, Ki Ho ;
Kim, Yeon-deok .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) :6424-6430
[9]   Anterior chamber angle imaging with optical coherence tomography [J].
Leung, C. K-S ;
Weinreb, R. N. .
EYE, 2011, 25 (03) :261-267
[10]   Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT [J].
Leung, Christopher Kai-Shun ;
Li, Haitao ;
Weinreb, Robert Neal ;
Liu, Jing ;
Cheung, Carol Yim Lui ;
Lai, Ricky Yiu Kwong ;
Pang, Chi Pui ;
Lam, Dennis Shun Chiu .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) :3469-3474