A portable multi-syringe flow system for spectrofluorimetric determination of iodide in seawater

被引:26
|
作者
Frizzarin, Rejane M. [1 ]
Aguado, Enrique [1 ]
Portugal, Lindomar A. [1 ]
Moreno, Daniel [1 ]
Estela, Jose M. [1 ]
Rocha, Fabio R. P. [2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Analyt Environm Chem Lab, Palma De Mallorca 07122, Spain
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
关键词
Flow analysis; MSFIA; Miniaturization; Chip; Fluorescence; Multivariate optimization; PLASMA-MASS SPECTROMETRY; CATALYTIC DETERMINATION; GIBBERELLIC-ACID; INJECTION; FLUORESCENCE; SAMPLES; ANALYZER; CHEMILUMINESCENCE; OPTIMIZATION; BROMINE;
D O I
10.1016/j.talanta.2015.07.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analyzer encompassing a poly(methyl methacrylate) chip with integrated spectrofluorimetric detection and solutions propelling by a multi-syringe module is proposed. Iodide was determined through its catalytic effect on the reaction between Ce(IV) and As(III). Matrix isopotential synchronous fluorescence was explored to set the excitation and emission wavelengths. A two-level full factorial design allowed to evaluate the significance of variables (Ce(IV), As(III) and H2SO4 concentrations) and their interaction effects in the experimental domain. A Doehlert Matrix was applied to identify the critical values. The optimized procedure showed a linear response from 1 to 100 mu g L-1 (S=53.7+2.61C, in which S is the net fluorescence and C is iodide concentration in jig L-1). Detection limit, coefficient of variation (n=6) and sampling rate were estimated at 0.3 mu g L-1, 0.8% and 20 h(-1), respectively. Recoveries within 90-117% were estimated for iodide spiked to seawater samples. The proposed procedure stands out because of the portability, robustness, and simplicity for in-field analysis of iodide in seawater. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1155 / 1162
页数:8
相关论文
共 50 条
  • [21] FLOW-INJECTION PROCEDURES FOR DETERMINATION OF IODIDE AND IODATE IODIDE WITH SPECTROFLUORIMETRIC AND SPECTROPHOTOMETRIC DETECTION, RESPECTIVELY
    YAQOOB, M
    MASOOM, M
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1991, 248 (01) : 219 - 224
  • [22] Pressure assisted multi-syringe single nozzle deposition system for manufacturing of heterogeneous tissue scaffolds
    Chetan Chimate
    Bahattin Koc
    The International Journal of Advanced Manufacturing Technology, 2014, 75 : 317 - 330
  • [23] A robust multi-syringe system for process flow analysis.: Part 3.: Time based injection applied to the spectrophotometric determination of nickel(II) and iron speciation
    Albertús, F
    Cladera, A
    Becerra, E
    Cerdà, V
    ANALYST, 2001, 126 (06) : 903 - 910
  • [24] A multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    MICROCHEMICAL JOURNAL, 2009, 93 (02) : 153 - 158
  • [25] Pressure assisted multi-syringe single nozzle deposition system for manufacturing of heterogeneous tissue scaffolds
    Chimate, Chetan
    Koc, Bahattin
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 75 (1-4): : 317 - 330
  • [26] Improving the chemiluminescence-based determination of sulphide in complex environmental samples by using a new, automated multi-syringe flow injection analysis system coupled to a gas diffusion unit
    Maya, Fernando
    Estela, Jose Manuel
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2007, 601 (01) : 87 - 94
  • [27] Automated spectrophotometric determination of carbonate ion concentration in seawater using a portable syringe pump based analyzer
    Shangguan, Qipei
    Shu, Huilin
    Li, Peicong
    Lin, Kunning
    Byrne, Robert H.
    Li, Quanlong
    Yuan, Dongxing
    Ma, Jian
    MARINE CHEMISTRY, 2019, 209 : 120 - 127
  • [28] Development of an automated system for the analysis of inorganic chloramines in swimming pools via multi-syringe chromatography and photometric detection with ABTS
    Chehab, Rana
    Coulomb, Bruno
    Boudenne, Jean-Luc
    Robert-Peillard, Fabien
    TALANTA, 2020, 207
  • [29] Development of Flow Injection Spectrofluorimetric Detection System for the Determination of Homocysteine
    Nouroozi, Siavash
    Biglary, Hassan
    Haghighi, Behzad
    JOURNAL OF FLUORESCENCE, 2012, 22 (01) : 365 - 371
  • [30] Development of Flow Injection Spectrofluorimetric Detection System for the Determination of Homocysteine
    Siavash Nouroozi
    Hassan Biglary
    Behzad Haghighi
    Journal of Fluorescence, 2012, 22 : 365 - 371