A portable multi-syringe flow system for spectrofluorimetric determination of iodide in seawater

被引:26
|
作者
Frizzarin, Rejane M. [1 ]
Aguado, Enrique [1 ]
Portugal, Lindomar A. [1 ]
Moreno, Daniel [1 ]
Estela, Jose M. [1 ]
Rocha, Fabio R. P. [2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Analyt Environm Chem Lab, Palma De Mallorca 07122, Spain
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
关键词
Flow analysis; MSFIA; Miniaturization; Chip; Fluorescence; Multivariate optimization; PLASMA-MASS SPECTROMETRY; CATALYTIC DETERMINATION; GIBBERELLIC-ACID; INJECTION; FLUORESCENCE; SAMPLES; ANALYZER; CHEMILUMINESCENCE; OPTIMIZATION; BROMINE;
D O I
10.1016/j.talanta.2015.07.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized analyzer encompassing a poly(methyl methacrylate) chip with integrated spectrofluorimetric detection and solutions propelling by a multi-syringe module is proposed. Iodide was determined through its catalytic effect on the reaction between Ce(IV) and As(III). Matrix isopotential synchronous fluorescence was explored to set the excitation and emission wavelengths. A two-level full factorial design allowed to evaluate the significance of variables (Ce(IV), As(III) and H2SO4 concentrations) and their interaction effects in the experimental domain. A Doehlert Matrix was applied to identify the critical values. The optimized procedure showed a linear response from 1 to 100 mu g L-1 (S=53.7+2.61C, in which S is the net fluorescence and C is iodide concentration in jig L-1). Detection limit, coefficient of variation (n=6) and sampling rate were estimated at 0.3 mu g L-1, 0.8% and 20 h(-1), respectively. Recoveries within 90-117% were estimated for iodide spiked to seawater samples. The proposed procedure stands out because of the portability, robustness, and simplicity for in-field analysis of iodide in seawater. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1155 / 1162
页数:8
相关论文
共 50 条
  • [1] Multi-syringe flow injection system for the determination of available phosphorus in soil samples
    Almeida, MIGS
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (01) : 51 - 62
  • [2] Multi-syringe flow injection system with in-line microwave digestion for the determination of phosphorus
    Almeida, MIGS
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    TALANTA, 2004, 64 (05) : 1283 - 1289
  • [3] Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system
    Gomes, DMC
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    TALANTA, 2005, 66 (03) : 703 - 711
  • [4] A Multi-Syringe Flow System for Monitoring Moderately Fast Chemical Reactions
    Cerda, Victor
    Ubide, Carlos
    Zuriarrain, Juan
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (11) : 1989 - 1996
  • [5] Multi-syringe flow injection system for the determination of the scavenging capacity of the diphenylpicrylhydrazyl radical in methanol and ethanolic media
    Magalhaes, Luis M.
    Segundo, Marcela A.
    Siquet, Christophe
    Reis, Salette
    Lima, Jose L. F. C.
    MICROCHIMICA ACTA, 2007, 157 (1-2) : 113 - 118
  • [6] Potentiometric multi-syringe flow injection system for determination of exchangeable potassium in soils with in-line extraction
    Almeida, M. Ines G. S.
    Segundo, Marcela A.
    Lima, Jose L. F. C.
    Rangel, Antonio O. S. S.
    MICROCHEMICAL JOURNAL, 2006, 83 (02) : 75 - 80
  • [7] Multi-syringe flow injection system for the determination of the scavenging capacity of the diphenylpicrylhydrazyl radical in methanol and ethanolic media
    Luís M. Magalhães
    Marcela A. Segundo
    Christophe Siquet
    Salette Reis
    José L. F. C. Lima
    Microchimica Acta, 2007, 157 : 113 - 118
  • [8] Multi-syringe flow injection system with in-line pre-concentration for the determination of total phenolic compounds
    Oliveira, HM
    Segundo, MA
    Reis, S
    Lima, JLFC
    MICROCHIMICA ACTA, 2005, 150 (02) : 187 - 196
  • [9] Multi-Syringe Flow Injection System with In-Line Pre-Concentration for the Determination of Total Phenolic Compounds
    Hugo M. Oliveira
    Marcela A. Segundo
    Salette Reis
    José L. F. C. Lima
    Microchimica Acta, 2005, 150 : 187 - 196
  • [10] Chip-Based Spectrofluorimetric Determination of Iodine in a Multi-Syringe Flow Platform with and without In-Line Digestion-Application to Salt, Pharmaceuticals, and Algae Samples
    Miranda, Joana L. A.
    Mesquita, Raquel B. R.
    Palacio, Edwin
    Estela, Jose M.
    Cerda, Victor
    Rangel, Antonio O. S. S.
    MOLECULES, 2022, 27 (04):