Comparison of Simulated Cone Beam Computed Tomography to Conventional Helical Computed Tomography for Imaging of Rhinosinusitis

被引:25
作者
Fakhran, Saeed [1 ]
Alhilali, Lea [1 ]
Sreedher, Gayathri [1 ]
Dohatcu, Andreea C. [2 ]
Lee, Stella [3 ]
Ferguson, Berrylin [3 ]
Branstetter, Barton F. [1 ,3 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Med, Dept Radiat Safety, Pittsburgh, PA USA
[3] Univ Pittsburgh, Sch Med, Dept Otolaryngol, Pittsburgh, PA USA
关键词
Cone beam computed tomography; multidetector computed tomography; sinusitis; FLAT-PANEL DETECTOR; SKULL-BASE SURGERY; HEAD CT PROTOCOL; ENDOSCOPIC SINONASAL; SINUS SURGERY; ARM; QUALITY; CHILDREN; GUIDANCE; REDUCTION;
D O I
10.1002/lary.24603
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: Cone beam computed tomography (CBCT) has emerged as a low radiation dose alternative to traditional computed tomography (CT) to evaluate the paranasal sinuses. The purpose of our study was to determine how often clinically important findings would be missed if CBCT was used routinely for sinus imaging. Study Design: Retrospective review. Methods: We evaluated all maxillofacial CT scans performed for sinusitis over a 1-year period. The original multidetector CT (MDCT) images were reviewed retrospectively. A theoretical CBCT was then created from the original study utilizing only the bone algorithm images and separately reviewed. We calculated the proportion of abnormal findings that were identified on the MDCT but would have been missed by the theoretical CBCT, and reviewed the medical record to determine which potentially missed findings would have changed management. Radiation dose from the MDCT scanners was calculated and compared to published dose estimates for the paranasal sinuses on CBCT. Results: Maxillofacial CTs from 361 consecutive patients were included, of which 12 (3.3%) demonstrated findings that would have been missed on the theoretical CBCT. Of those, four (1.1%) would have resulted in a change in management. Effective radiation dose for our scanners ranged from 0.67 mSv to 2.15 mSv, compared to a published estimated dose of 0.2 mSV for CBCT. Conclusions: In the majority of patients undergoing simulated CBCT for evaluation of sinusitis, incidental findings of soft-tissue disease were rare. With appropriate selection of patients, CBCT can offer substantial radiation dose reduction and may provide a viable alternative to standard MDCT sinus imaging protocols.
引用
收藏
页码:2002 / 2006
页数:5
相关论文
共 32 条
[1]   Evaluation of a Limited Three-Slice Head CT Protocol for Monitoring Patients With Ventriculoperitoneal Shunts [J].
Alhilali, Lea M. ;
Dohatcu, Andreea C. ;
Fakhran, Saeed .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) :400-405
[2]   Dose and image quality of flat-panel detector volume computed tomography for sinus imaging [J].
Alspaugh, J. ;
Christodoulou, E. ;
Goodsitt, M. ;
Stayman, J. .
MEDICAL PHYSICS, 2007, 34 (06) :2634-2634
[3]  
American Association of Physicists in Medicine, 2008, 96 AM ASS PHYS MED T
[4]   Antimicrobial treatment guidelines for acute bacterial rhinosinusitis - Executive summary [J].
Anon, JB ;
Jacobs, MR ;
Roche, R ;
Poole, MD ;
Merck, D ;
Ambrose, PG ;
Benninger, MS ;
Hadley, JA ;
Craig, WA ;
Andes, DR ;
Bernstein, JM ;
Besser, RE ;
Dowell, SF ;
Drusano, GL ;
Klepser, ME ;
Nicolau, D ;
Radowsky, A ;
Reller, LB ;
Wald, ER ;
Zucker, DR .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 130 (01) :1-45
[5]  
Bacher K, 2009, INT FED MED BIOL ENG
[6]   Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures [J].
Batra, Pete S. ;
Kanowitz, Seth J. ;
Citardi, Martin J. .
AMERICAN JOURNAL OF RHINOLOGY, 2008, 22 (05) :511-515
[7]   Prospective evaluation of intraoperative computed tomography imaging for endoscopic sinonasal and skull-base surgery [J].
Batra, Pete S. ;
Manes, R. Peter ;
Ryan, Matthew W. ;
Marple, Bradley F. .
INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2011, 1 (06) :481-487
[8]   Intraoperative IGS/CT updates for complex endoscopic frontal sinus surgery [J].
Chennupati, Sri Kiran ;
Woodworth, Bradford A. ;
Palmer, James N. ;
Cohen, Noam A. ;
Kennedy, David W. ;
Chiu, Alexander G. .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2008, 70 (04) :268-270
[9]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[10]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780