Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes

被引:13
|
作者
Deuter, CME [1 ]
Schlote, T [1 ]
Hahn, GA [1 ]
Bende, T [1 ]
Derse, M [1 ]
机构
[1] Univ Tubingen, Augenklin, Abt Erkrankungen Vorderen & Hinteren Augenabschni, D-72076 Tubingen, Germany
关键词
glaucoma; intraocular pressure; tonometry;
D O I
10.1055/s-2002-26718
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: In clinical practice ophthalmologists often need a tonometer which is independent of a slit lamp. Such a hand-held device is the Tono-Pen. We compared the precision of two equal Tono-Pens with Goldmann applanation tonometry. Material and methods: Measurement of intraocular pressure (IOP) was done in 100 eyes of 51 patients (mean age 63 15 years) suffering from ocular hypertension or glaucoma. According to a random table either the right or left eye was measured using Goldmann tonometer first and the Torio-Pen second. For the other eye the measurement was reversed. One of the two equal Tono-Pens (So-Ian/USA) was used according to a second random table. Three measurements were obtained with each instrument on both eyes within 15 minutes subsequently. Patients were placed in an upright position for all measurements. Results: Even for well-trained ophthalmologists a learning curve of approximately 10 measurements was observed using the Tono-Pen. The Tono-Pen measured an average IOP of 16.9 mm Hg in all 100 eyes. The Goldmann tonometer measured an average IOP of 17.7 mm Hg. The difference was not statistically significant. The standard deviation for all measurements was better for the Tono-Pen (4.7 mm Hg vs 5.8 mm Hg for Goldmann tonometer). No reduction of the IOP after Tono-Pen measurement was observed (in contrast to the Goldmann tonometer). The reproducibility of the Tono-Pen on the same eye was inferior to the Goldmann tonometer by a factor of 2. There was an almost significant difference in reproducibility between two equal Tono-Pens. Conclusions: Measurement of IOP with the Tono-Pen is comparable to Goldmann applanation tonometry if an average of 3 measurements is used. The difference between two equal Tono-Pens indicates the need for improvement of the quality check during production.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 50 条
  • [11] TONOMETRY COMPARISON - GOLDMANN VERSUS TONO-PEN
    KOONER, KS
    COOKSEY, JC
    BARRON, JB
    ZIMMERMAN, TJ
    GUPTE, RK
    WALL, JL
    ANNALS OF OPHTHALMOLOGY, 1992, 24 (01): : 29 - 36
  • [12] 24-hour intraocular pressure (IOP) monitoring with Goldmann applanation (GAT) tonometry and Tono-Pen AVIA® in keratoconic eyes.
    Merula, Rafael Vidal
    Cronemberger, Sebastiao
    Veloso, Artur C.
    Diniz-Filho, Alberto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [13] CLINICAL COMPARISON OF THE PROTON AND TONO-PEN TONOMETERS WITH THE GOLDMANN APPLANATION TONOMETER
    MIDELFART, A
    WIGERS, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (12) : 895 - 898
  • [14] Clinical comparison of the Proview™ eye pressure monitor with Goldmann applanation tonometer and Tono-Pen
    Li, J
    Herndon, LW
    Stinnett, S
    Asrani, SG
    Allingham, RR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U13 - U13
  • [15] A CLINICAL COMPARISON OF THE OCULAB TONO-PEN WITH THE GOLDMANN APPLANATION TONOMETER IN EYES FILLED WITH SILICONE OIL
    ALFARO, DV
    TRAN, VT
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1991, 11 (02): : 219 - 220
  • [16] The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
    Tonnu, PA
    Ho, T
    Newson, T
    El Sheikh, A
    Sharma, K
    White, E
    Bunce, C
    Garway-Heath, D
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (07) : 851 - 854
  • [17] Measurements of Intraocular Pressure with Tono-Pen and Goldmann Applanation Tonometers in Subjects with Systemic Illness
    Hsu, Sheng-Yao
    Lin, Shu-Fang
    Hsu, Ai-Hsi
    TZU CHI MEDICAL JOURNAL, 2007, 19 (04): : 241 - 244
  • [18] The relationship between intraocular pressure and central corneal thickness: A comparison between the Tono-Pen and Goldmann applanation
    Zhao, F
    Thomas, S
    Enzenauer, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S515 - S515
  • [19] Twenty-four hours intraocular pressure in keratoconic eyes assessed by applanation tonometry and Tono-Pen AVIA
    Rafael Vidal Merola
    Sebasti?o Cronemberger
    Artur William Veloso
    Alberto Diniz-Filho
    International Journal of Ophthalmology, 2022, (01) : 52 - 58
  • [20] The Impact of Corneal Edema on Intraocular Pressure Measurements Using Goldmann Applanation Tonometry, Tono-Pen XL, iCare, and ORA: An In Vitro Model
    Neuburger, Matthias
    Maier, Philip
    Boehringer, Daniel
    Reinhard, Thomas
    Jordan, Jens F.
    JOURNAL OF GLAUCOMA, 2013, 22 (07) : 584 - 590