Measurement of renal volumes with contrast-enhanced MRI

被引:63
作者
Coulam, CH [1 ]
Bouley, DM [1 ]
Sommer, FG [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Sch Med, Stanford, CA 94305 USA
关键词
kidney; MRI; volume; cortex; medulla;
D O I
10.1002/jmri.10058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the accuracy of in vivo magnetic resonance imaging (MRI) measurement of total renal parenchymal volume and medullary fraction. Materials and Methods: Sixteen kidneys in eight pigs were imaged with a multiphasic contrast-enhanced fast three-dimensional sequence on a 1.5-T imager. Kidney segmentation, followed by a process of signal intensity thresholding for cortical and nephrographic phase datasets, allowed for MRI measurements of parenchymal volume and medullary fraction. Autopsy provided reference standards of renal Volume, weight. and medullary fraction. Results: An excellent correlation was found between MRI measurement of total renal parenchymal volume and autopsy volume (R-2 = 0.86) and weight (R-2 = 0.90). Medullary fraction (mean +/- SD) measured with MRI was 0.120 +/- 0.067, and with autopsy was 0.116 +/- 0.025 (t-test P = 0.84, F-test P = 0.001). Conclusion: MRI measurements of total renal volume are accurate. MRI measurements of medullary fraction show promise, but precision is limited when using a simple signal intensity thresholding algorithm.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 26 条
  • [1] Ultrafast contrast-enhanced three-dimensional MR angiography: State of the art
    Alley, MT
    Shifrin, RY
    Pelc, NJ
    Herfkens, RJ
    [J]. RADIOGRAPHICS, 1998, 18 (02) : 273 - 285
  • [2] In vitro measurement of kidney size: Comparison of ultrasonography and MRI
    Bakker, J
    Olree, M
    Kaatee, R
    de Lange, EE
    Beek, FJA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (05) : 683 - 688
  • [3] Renal volume measurements: Accuracy and repeatability of US compared with that of MR imaging
    Bakker, J
    Olree, M
    Kaatee, R
    de Lange, EE
    Moons, KGM
    Beutler, JJ
    Beek, FJA
    [J]. RADIOLOGY, 1999, 211 (03) : 623 - 628
  • [4] Renal cancer: Preoperative evaluation with dual-phase three-dimensional MR angiography
    Choyke, PL
    Walther, MM
    Wagner, JR
    Rayford, W
    Lyne, JC
    Linehan, WM
    [J]. RADIOLOGY, 1997, 205 (03) : 767 - 771
  • [5] Sonographic renal parenchymal and pelvicaliceal areas: New quantitative parameters for renal sonographic followup
    Cost, GA
    Merguerian, PA
    Cheerasarn, SP
    Shortliffe, LMD
    [J]. JOURNAL OF UROLOGY, 1996, 156 (02) : 725 - 729
  • [6] Coulam CH, 2000, RADIOLOGY, V217, P455
  • [7] Dantzler W. H., 2016, COMP PHYSL VERTEBRAT
  • [8] Flow quantitation with echo-planar phase-contrast velocity mapping: In vitro anti in vivo evaluation
    Debatin, JF
    Leung, DA
    Wildermuth, S
    Botnar, R
    Felblinger, J
    McKinnon, GC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 656 - 662
  • [9] RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING
    DEBATIN, JF
    TING, RH
    WEGMULLER, H
    SOMMER, FG
    FREDRICKSON, JO
    BROSNAN, TJ
    BOWMAN, BS
    MYERS, BD
    HERFKENS, RJ
    PELC, NJ
    [J]. RADIOLOGY, 1994, 190 (02) : 371 - 378
  • [10] NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING
    DUMOULIN, CL
    BUONOCORE, MH
    OPSAHL, LR
    KATZBERG, RW
    DARROW, RD
    MORRIS, TW
    BATEY, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 370 - 378