Three-Dimensional Microsurgical Anatomy of the Choroid Plexus Using the Volume Rendering Technique

被引:3
作者
Kuruoglu, Enis [1 ]
Cokluk, Cengiz [1 ]
Marangoz, Abdullah Hilmi [1 ]
Aydin, Kerameddin [1 ]
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Neurosurg, Samsun, Turkey
关键词
Choroid plexus; Volume rendering; Surgical anatomy; Three-dimensional images; Computerized tomography;
D O I
10.5137/1019-5149.JTN.11473-14.1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
AIM: The choroid plexus (CP) is a specific anatomical structure producing cerebrospinal fluid into the ventricular space. The three-dimensional anatomical structure of the choroid plexus located within the lateral ventricle may be evaluated by using the three dimensional volume rendering technique (3D-VRT) from acquired two-dimensional contrast enhanced computerized tomographic images. MATERIAL and METHODS: The raw data of Three-dimensional Computerized Tomography Angiography (3D-CIA) were transferred into the computer and recorded in a software program. These images were evaluated in terms of anatomical shape, borders, extensions length and dimensions. RESULTS: The patient group consisted of 57 (27 female and 30 male) patients. The mean age of the patients was 55 +/- 9 years. In male individuals, the distance of the superior tip from Frazier's point was 7.96 +/- 0.71 centimeters at the right side. In males, the distance of the inferior tip of the CP was estimated as 1.93 +/- 0.26 centimeters posterior-lateral from the anterior clinoid process, 1.64 +/- 0.23 centimeters posterior-lateral from the bifurcation of internal carotid artery, and 2.86 +/- 0.23 centimeters posterior-medial from the bifurcation of middle cerebral artery on the right side. CONCLUSION:The results of this study showed us that this technique could be used in the three-dimensional evaluation of some anatomical structures such as the choroid plexus.
引用
收藏
页码:914 / 921
页数:8
相关论文
共 8 条
[1]   Three-dimensional volume rendering of spiral CT data: Theory and method [J].
Calhoun, PS ;
Kuszyk, BS ;
Heath, DG ;
Carley, JC ;
Fishman, EK .
RADIOGRAPHICS, 1999, 19 (03) :745-764
[2]  
Damiani D, 2010, J MORPHOL SCI, V27, P130
[3]   Volume rendering [J].
Drebin, Robert A. ;
Carpenter, Loren ;
Hanrahan, Pat .
Computer Graphics (ACM), 1988, 22 (04) :65-74
[4]   Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary? [J].
Hwang, Seung Bae ;
Kwak, Hyo Sung ;
Han, Young Min ;
Chung, Gyung Ho .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :E18-E23
[5]   The structure of the choroid plexus and the physiology of the choroid plexus epithelium [J].
Redzic, ZB ;
Segal, MB .
ADVANCED DRUG DELIVERY REVIEWS, 2004, 56 (12) :1695-1716
[6]   The cerebrum [J].
Rhoton, AL .
NEUROSURGERY, 2002, 51 (04) :S1-S52
[7]   The lateral and third ventricles [J].
Rhoton, AL .
NEUROSURGERY, 2002, 51 (04) :S207-S272
[8]   MICRO-SURGERY OF THE 3RD VENTRICLE .2. OPERATIVE APPROACHES [J].
RHOTON, AL ;
YAMAMOTO, I ;
PEACE, DA .
NEUROSURGERY, 1981, 8 (03) :357-373