3D-printed orthodontic brackets - proof of concept

被引:2
作者
Krey, K-F [1 ]
Darkazanly, N. [1 ]
Kuehnert, R. [2 ]
Ruge, S. [3 ]
机构
[1] Ernst Moritz Arndt Univ Greifswald, Univ Med Greifswald, Poliklin Kieferorthopadie, Greifswald, Germany
[2] Image Instruments GmbH, Chemnitz, Germany
[3] Ernst Moritz Arndt Univ Greifswald, Zentrum Zahn Mund & Kieferheilkunde, Digitale Zahnmed Okklus & Kaufunkt Therapie, Greifswald, Germany
关键词
orthodontic treatment; digital workflow; 3D-printed brackets; STRAIGHT-WIRE; APPLIANCE;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Today, orthodontic treatment with fixed appliances is usually carried out using preprogrammed straight-wire brackets made of metal or ceramics. Objective: The goal of this study was to determine the possibility of clinically implementing a fully digital workflow with individually designed and three-dimensionally printed (3D-printed) brackets. Materials and methods: Edgewise brackets were designed using computer-aided design (CAD) software for demonstration purposes. After segmentation of the malocclusion model generated based on intraoral scan data, the brackets were digitally positioned on the teeth and a target occlusion model created. The thus-defined tooth position was used to generate a template for an individualized arch form in the horizontal plane. The base contours of the brackets were modified to match the shape of the tooth surfaces, and a positioning guide (fabricated beforehand) was used to ensure that the brackets were bonded at the correct angle and position. The brackets, positioning guide, and retainer splint, digitally designed on the target occlusion model, were 3D printed using a Digital Light Processing (DLP) 3D printer. The archwires were individually pre-bent using the template. Results: In the treatment sequence, it was shown for the first time that, in principle, it is possible to perform treatment with an individualized 3D-printed brackets system by using the proposed fully digital workflow. Technical aspects of the system, problems encountered in treatment, and possible future developments are discussed in this article.
引用
收藏
页码:351 / 362
页数:12
相关论文
共 18 条
[1]   Laboratory evaluation of modern plastic brackets [J].
Ali, Omar ;
Makou, Margarita ;
Papadopoulos, Triantafillos ;
Eliades, George .
EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (05) :595-602
[2]   6 KEYS TO NORMAL OCCLUSION [J].
ANDREWS, LF .
AMERICAN JOURNAL OF ORTHODONTICS, 1972, 62 (03) :296-&
[3]  
Angle EH., 1929, Dental Cosmos, Philadelphia, V71, P260
[4]  
Angle EH, 1970, TREATMENT MALOCCLUSI
[5]  
Conner B. P., 2014, Addit. Manuf, V1-4, P64, DOI DOI 10.1016/J.ADDMA.2014.08.005
[6]   STRAIGHT WIRE - THE NEXT-GENERATION [J].
CREEKMORE, TD ;
KUNIK, RL .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 104 (01) :8-20
[7]   SCIENTIFIC ASSESSMENT OF STRAIGHT-WIRE APPLIANCE [J].
DELLINGER, EL .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1978, 73 (03) :290-299
[8]  
Graber L.W., 2011, ORTHODONTICS CURRENT, V5th
[9]  
Gracco Antonio, 2011, J Clin Orthod, V45, P442
[10]   Accuracy in tooth positioning with a fully customized lingual orthodontic appliance [J].
Grauer, Dan ;
Proffit, William R. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :433-443