Comparison of Visual Stimuli for Steady-State Visual Evoked Potential-Based Brain-Computer Interfaces in Virtual Reality Environment in terms of Classification Accuracy and Visual Comfort

被引:16
作者
Choi, Kang-min [1 ]
Park, Seonghun [1 ]
Im, Chang-Hwan [1 ]
机构
[1] Hanyang Univ, Dept Biomed Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
关键词
MULTIVARIATE SYNCHRONIZATION INDEX; FREQUENCY RECOGNITION; SYSTEM;
D O I
10.1155/2019/9680697
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recent studies on brain-computer interfaces (BCIs) based on the steady-state visual evoked potential (SSVEP) have demonstrated their use to control objects or generate commands in virtual reality (VR) environments. However, most SSVEP-based BCI studies performed in VR environments have adopted visual stimuli that are typically used in conventional LCD environments without considering the differences in the rendering devices (head-mounted displays (HMDs) used in the VR environments). The proximity between the visual stimuli and the eyes in HMDs can readily cause eyestrain, degrading the overall performance of SSVEP-based BCIs. Therefore, in the present study, we have tested two different types of visual stimuli-pattern-reversal checkerboard stimulus (PRCS) and grow/shrink stimulus (GSS)-on young healthy participants wearing HMDs. Preliminary experiments were conducted to investigate the visual comfort of each participant during the presentation of the visual stimuli. In subsequent online avatar control experiments, we observed considerable differences in the classification accuracy of individual participants based on the type of visual stimuli used to elicit SSVEP. Interestingly, there was a close relationship between the subjective visual comfort score and the online performance of the SSVEP-based BCI: most participants showed better classification accuracy under visual stimulus they were more comfortable with. Our experimental results suggest the importance of an appropriate visual stimulus to enhance the overall performance of the SSVEP-based BCIs in VR environments. In addition, it is expected that the appropriate visual stimulus for a certain user might be readily selected by surveying the user's visual comfort for different visual stimuli, without the need for the actual BCI experiments.
引用
收藏
页数:7
相关论文
共 33 条
[1]   BCI Demographics: How Many (and What Kinds of) People Can Use an SSVEP BCI? [J].
Allison, Brendan ;
Lueth, Thorsten ;
Valbuena, Diana ;
Teymourian, Amir ;
Volosyak, Ivan ;
Graeser, Axel .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2010, 18 (02) :107-116
[2]   Visual fatigue caused by stereoscopic images and the search for the requirement to prevent them: A review [J].
Bando, Takehiko ;
Iijima, Atsuhiko ;
Yano, Sumio .
DISPLAYS, 2012, 33 (02) :76-83
[3]   An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method [J].
Bin, Guangyu ;
Gao, Xiaorong ;
Yan, Zheng ;
Hong, Bo ;
Gao, Shangkai .
JOURNAL OF NEURAL ENGINEERING, 2009, 6 (04)
[4]  
Chumerin N, 2012, RIV PUB S INFORM SCI, P1
[5]   Brain-Computer Interface Control in a Virtual Reality Environment and Applications for the Internet of Things [J].
Coogan, Christopher G. ;
He, Bin .
IEEE ACCESS, 2018, 6 :10840-10849
[6]   Tradeoff between User Experience and BCI Classification Accuracy with Frequency Modulated Steady-State Visual Evoked Potentials [J].
Dreyer, Alexander M. ;
Herrmann, Christoph S. ;
Rieger, Jochem W. .
FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11
[7]   Towards an Optimization of Stimulus Parameters for Brain-Computer Interfaces Based on Steady State Visual Evoked Potentials [J].
Duszyk, Anna ;
Bierzynska, Maria ;
Radzikowska, Zofia ;
Milanowski, Piotr ;
Kus, Rafal ;
Suffczynski, Piotr ;
Michalska, Magdalena ;
Labecki, Maciej ;
Zwolinski, Piotr ;
Durka, Piotr .
PLOS ONE, 2014, 9 (11)
[8]  
Faller J., 2017, A Feasibility Study on SSVEP-Based Interaction with Motivating and Immersive Virtual and Augmented Reality
[9]   Subject response variability in terms of colour and frequency of capacitive SSVEP measurements [J].
Gerloff, M. ;
Schilling, M. .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 :95-98
[10]  
Guo J, 2017, P IEEE VIRT REAL ANN, P249, DOI 10.1109/VR.2017.7892270