Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial

被引:55
作者
Elsyad, M. A. [1 ]
Elsaih, E. A. [1 ]
Khairallah, A. S. [1 ]
机构
[1] Mansoura Univ, Fac Dent, Dept Removable Prosthodont, Mansoura, Egypt
关键词
immediate loading; locator; bone loss; implant; overdentures; RESONANCE FREQUENCY-ANALYSIS; DENTURE-BEARING AREA; LOADING PROTOCOLS; UNSPLINTED IMPLANTS; ATTACHMENT SYSTEMS; DENTAL IMPLANTS; CLINICAL-TRIAL; INTERFACE; STABILITY; RETENTION;
D O I
10.1111/joor.12182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this 1-year study was to evaluate and compare crestal bone loss and clinical outcomes of immediate and delayed loaded implants supporting mandibular overdentures with Locator attachments. In a randomised controlled clinical trial, 36 completely edentulous patients (mean age 59.6 years) who desired to improve the stability of their mandibular dentures were randomly assigned into two groups. Each patient received two implants in the canine area of the mandible after a minimal flap reflection. Implants were loaded by mandibular overdentures either 3 months (delayed loading group, G1) or the same day (immediate loading group, G2) after implant placement. Locator attachments were used to retain all overdentures to the implants. Peri-implant vertical (VBL) and horizontal (HBLO) bone losses and clinical parameters [ plaque scores (PI), gingival scores (GI), probing depths (PD) and implant stability (ISQ)] were assessed at time of overdenture insertion (T0), 6 months (T6) and 12 months (T12) after overdenture insertion. After 12 months of overdenture insertion, two implants (5.5%) failed in G2. Vertical bone loss was significantly higher in G2 compared with G1, while HBLO demonstrated insignificant differences between groups. All clinical parameters (PI, GI, PD and ISQ) did not differ significantly between groups. Vertical bone loss was significantly correlated with PD and HBLO. Immediately loaded two implants supporting a Locator-retained mandibular overdenture are associated with more vertical bone resorption when compared to delayed loaded implants after 1 year. Clinical outcomes do not differ significantly between loading protocols.
引用
收藏
页码:608 / 618
页数:11
相关论文
共 49 条
[1]  
Akça K, 2007, INT J ORAL MAX IMPL, V22, P101
[2]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[3]  
Albrektsson T, 1993, Int J Prosthodont, V6, P95
[4]  
Alfadda SA, 2009, INT J PROSTHODONT, V22, P368
[5]   Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems [J].
Alsabeeha, Nabeel H. M. ;
Payne, Alan G. T. ;
De Silva, Rohana K. ;
Thomson, W. Murray .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) :330-337
[6]   The revised CONSORT statement for reporting randomized trials: Explanation and elaboration [J].
Altman, DG ;
Schulz, KF ;
Moher, D ;
Egger, M ;
Davidoff, F ;
Elbourne, D ;
Gotzsche, PC ;
Lang, T .
ANNALS OF INTERNAL MEDICINE, 2001, 134 (08) :663-694
[7]   Immediate and early implant loading protocols: A literature review of clinical studies [J].
Attard, NJ ;
Zarb, GA .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (03) :242-258
[8]   Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures [J].
Bernhart, Gunda ;
Koob, Andreas ;
Schmitter, Marc ;
Gabbert, Olaf ;
Stober, Thomas ;
Rammelsberg, Peter .
CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) :1031-1037
[9]   A CLASSIFICATION OF THE EDENTULOUS JAWS [J].
CAWOOD, JI ;
HOWELL, RA .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 17 (04) :232-236
[10]   Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures [J].
Celik, Gozde ;
Uludag, Bulent .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04) :229-235