Quantitative analysis of pesticide residue based on the dynamic response of a single SnO2 gas sensor

被引:33
作者
Huang, XJ
Wang, LC
Sun, YF
Meng, FL
Liu, JH [1 ]
机构
[1] Chinese Acad Sci, Hefei Inst Intelligent Machines, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Dept Chem, Anhua 230026, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 99卷 / 2-3期
基金
中国国家自然科学基金;
关键词
SnO2 gas sensor; modulating temperature; pesticide residue; gas analysis;
D O I
10.1016/j.snb.2003.11.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new rapid detecting method (called dynamic measurements) was reported to detect and distinguish the presence of two pesticide gases and their mixture in the ambient atmosphere. The method employed only a single SnO2-based gas sensor in a rectangular temperature mode to perform the qualitative analysis of pure pesticide gas and a binary gas mixture (acephate and trichlorphon) in air. Experimental results showed that a high selectivity of the sensor was achieved in the range of 250-300 degreesC and modulating frequency 20 mHz. The quantitative analysis between the pure pesticide gas and the mixture was performed by a fast Fourier transformation (FFT). The higher harmonics of the FFT characterized the nonlinear properties of the response at the sensor surface. The amplitudes of the higher harmonics exhibited characteristic changes which depended on the gas concentration and the kinetics of the gas species on the sensor surface. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 25 条
[1]  
ANATOLIY VZ, 1997, ANAL CHIM ACTA, V347
[2]   VALIDATION OF AN ENZYMATIC BIOSENSOR WITH LIQUID-CHROMATOGRAPHY FOR PESTICIDE MONITORING [J].
BARCELO, D ;
LACORTE, S ;
MARTY, JL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :334-340
[3]  
BARSAN N, 1994, SENSOR ACTUAT B-CHEM, V19, P466, DOI 10.1016/0925-4005(93)01041-2
[4]   Optimized temperature-pulse sequences for the enhancement of chemically specific response patterns from micro-hotplate gas sensors [J].
Cavicchi, RE ;
Suehle, JS ;
Kreider, KG ;
Gaitan, M ;
Chaparala, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :142-146
[5]   SNO2 SENSORS - CURRENT STATUS AND FUTURE-PROSPECTS [J].
GOPEL, W ;
SCHIERBAUM, KD .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) :1-12
[6]  
Hans J S., 2000, J CHROMATOGR A, V892, P347
[7]   Gas identification by modulating temperatures of SnO2-based thick film sensors [J].
Heilig, A ;
Barsan, N ;
Weimar, U ;
Schweizer-Berberich, M ;
Gardner, JW ;
Gopel, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) :45-51
[8]   Rectangular mode of operation for detecting pesticide residue by using a single SnO2-based gas sensor [J].
Huang, XJ ;
Liu, JH ;
Shao, DL ;
Pi, ZX ;
Yu, ZL .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) :630-635
[9]  
Ihokura K., 1994, STANNIC OXIDE GAS SE
[10]   Temperature modulation in semiconductor gas sensing [J].
Lee, AP ;
Reedy, BJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 60 (01) :35-42