Probes for measuring heat transfer parameters and fouling intensity in boilers

被引:25
作者
Paist, A [1 ]
Poobus, A [1 ]
Tiikma, T [1 ]
机构
[1] Tallinn Univ Technol, Dept Thermal Engn, EE-11712 Tallinn, Estonia
关键词
thermal efficiency; probes; fouling; ash deposits;
D O I
10.1016/S0016-2361(02)00114-X
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Some constructions of probes used in Tallinn Technical University for investigation of fouling intensity and heat transfer in solid fuel boilers are presented. The strong separation must be done between the operation conditions of probes for measuring the incident and resultant heat fluxes. For measuring resultant fluxes the idea of heat conductivity in thick metal wall mainly is used. Some results of measuring the thermal efficiency dynamic in boilers for Siberian brown coal, Donetsk coal and black liquor are presented. These results are compared with the data on laboratory investigation of the emissivity of ash deposits. (C) 2002 Elsevier Science Ltd. All tights reserved.
引用
收藏
页码:1811 / 1818
页数:8
相关论文
共 15 条
  • [1] A review of measurements of heat flux density applicable to the field of combustion
    Arai, N
    Matsunami, A
    Churchill, SW
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1996, 12 (04) : 452 - 460
  • [2] Blokh A. G., 1988, HEAT TRANSFER STEAM, P283
  • [3] BRAJUSKOVIC B, 1990, P 9 INT HEAT TRANSF, V3, P253
  • [4] A FURNACE WALL ASH MONITORING-SYSTEM FOR COAL FIRED BOILERS
    CHAMBERS, AK
    WYNNYCKYJ, JR
    RHODES, E
    [J]. JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1981, 103 (03): : 532 - 538
  • [5] A radiation and convection fluxmeter for high temperature applications
    Martins, N
    Carvalho, MG
    Afgan, N
    Leontiev, AI
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2000, 22 (3-4) : 165 - 173
  • [6] MIKK I, 1984, PROMYSHLENNAYA TEPLO, V6, P96
  • [7] OTS A, 1973, TEPLOENERGETIKA, V9, P2
  • [8] POOBUS A, 1983, T TALLINN TU, V546, P121
  • [9] Sparrow E.W., 1966, RAD HEAT TRANSFER
  • [10] SUURKUUSK T, 1992, P TALLINN TU, V732, P79