Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph

被引:10
作者
Chang, Chun-Hao [1 ]
Lin, Kuo-Chuan [2 ]
Ho, Chin-Shan [1 ]
Huang, Chi-Chang [1 ]
机构
[1] Natl Taiwan Sport Univ, Grad Inst Sports Sci, 250,Wenhua 1st Rd, Taoyuan, Taiwan
[2] Chung Yuan Christian Univ, Off Phys Educ, 200 Chung Pei Rd, Taoyuan, Taiwan
关键词
Accelerometer; Heart rate; Oxygen uptake; Physical activity; Uphill exercise; HEART-RATE; ACCELEROMETRY; VALIDITY; WALKING; VALIDATION; RESERVE;
D O I
10.1016/j.jesf.2019.01.003
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background/objective: The application of Micro-Electro-Mechanical Sensors (MEMS) as measurements of energy expenditure (EE) has certain disadvantages. For example, the inertial sensors cannot easily distinguish changes in ground slope during walking/running conditions, so the accuracy of EE calculation is biased. To resolve this issue, heart rate (HR) and heart rate reserve (HRR) were used as compensatory factors respectively to correct the classical empirical formula of the accelerometer analyzer for EE in this study. Methods: To explore the improvement of the accuracy of EE during uphill exercise and compare the correction levels between HR and HRR, oxygen uptake was used as a criterion measure (CM). Thirty healthy adult males wore an ActiGraph GT3X with the Polar HR monitor and Vmax indirect calorimeter during twelve treadmill activities (3 gradients and 4 speeds). Results: When the slopes were increased by 0%, 3%, and 6%, the measurement accuracy of the accelerometers, calculated by intraclass correlation coefficient (ICC), decreased by 0.877, 0.755, and 0.504, respectively (p <0.05). The HR and HRR parameters of linear regression were used to correct the classical formula. The results showed that HR had higher coefficients of determination (R2) (0.801, 0.700, and 0.642 respectively) and ICCs (0.887, 0.825, and 0.785 respectively) than did the accelerometer outputs. HRR showed the highest coefficients of determination (R2) (0.821, 0.728, and 0.656 respectively) and ICCs (0.901, 0.844, and 0.795 respectively). Conclusions: Through adding HRR parameters, the accuracy of the classical prediction formula EE was significantly improved during walking/running on sloping ground. (C) 2019 The Society of Chinese Scholars on Exercise Physiology and Fitness. Published by Elsevier (Singapore) Pte Ltd.
引用
收藏
页码:62 / 66
页数:5
相关论文
共 43 条
[1]  
ActiGraph, WHAT IS DIFF EN EXP, P37
[2]   Automatic Heart Rate Normalization for Accurate Energy Expenditure Estimation An Analysis of Activities of Daily Living and Heart Rate Features [J].
Altini, M. ;
Penders, J. ;
Vullers, R. ;
Amft, O. .
METHODS OF INFORMATION IN MEDICINE, 2014, 53 (05) :382-388
[3]  
[Anonymous], American Heart Association recommendations for physical activity in adults and kids
[4]  
[Anonymous], EX IS MED
[5]   Validity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometer [J].
Barnett A. ;
Cerin E. ;
Vandelanotte C. ;
Matsumoto A. ;
Jenkins D. .
BMC Sports Science, Medicine and Rehabilitation, 7 (1) :1-11
[6]   Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures [J].
Bassett, David R. ;
Troiano, Richard P. ;
Mcclain, James J. ;
Wolff, Dana L. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (04) :833-838
[7]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[8]  
Bauman A E, 2004, J Sci Med Sport, V7, P6, DOI 10.1016/S1440-2440(04)80273-1
[9]   Estimation of energy expenditure in a work environment: Comparison of accelerometry and oxygen consumption/heart rate regression [J].
Bouchard, D. R. ;
Trudeau, F. .
ERGONOMICS, 2008, 51 (05) :663-670
[10]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454