Modification of placental blood flow by hemodilution in high-risk pregnancies:: Discrimination between responder and non-responder using power Doppler sonography

被引:0
作者
Joern, H.
Erki, I.
Tschakert, L.
Rath, W.
机构
[1] Frauenarztpraxis, Aachen, Germany
[2] Univ Aachen, Tech Hsch Aachen, Klinikum Rheinisch Westfalischen, Frauenklin Gynakol & Geburtshilfe,ICE Consulting, D-5100 Aachen, Germany
关键词
hemodilution; high-risk pregnancy; placental blood flow; power Doppler sonography;
D O I
10.1055/s-2006-924188
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: Can hemodilution therapy change the intraplacental blood flow in high-risk pregnancies and is it possible to demonstrate this non-invasively and in vivo? Methods: 32 pregnant women (hematocrit > 38%, abdominal circumference < 5th centile and/ or Doppler flow > 60th centile for the umbilical and > 90th centile for the uterine artery by sonographic measurement) underwent hemodilution therapy (1-4 cycles of 500 ml hydroxyethyl starch 10%/500ml Ringer lactate daily for two weeks) at 29 weeks (median). Power Doppler ultrasound was performed before and 90 minutes after the therapy. The setting of the machine was always the same. The Doppler gate was placed over the parenchymatous part of the placenta excluding the umbilical cord vessels as well as the vessels of the chorionic and basal plates. The dispersion coefficient (standard deviation of local mean values/global mean of intensity-weighted distribution of colour pixels in the 8 x 4 block), the "Inverse Difference Moment" and the "Second Angular Moment" of the co-occurrence matrix were calculated using special software. Results: In 15/32 cases the outcome of pregnancy was sufficient (median gestational age 39 weeks, median birthweight 2890 g). All parameters changed significantly. In 17/32 cases premature delivery occurred because of foetal distress (median gestational age 33 weeks, median birthweight 1690 g). None of the parameters showed significant changes. Conclusion: In cases of sufficient outcome blood flow we were able the demonstrate an improved blood flow in the sense of our analysis.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 17 条
  • [1] One-stage screening for pregnancy complications by color Doppler assessment of the uterine arteries at 23 weeks' gestation
    Albaiges, G
    Missfelder-Lobos, H
    Lees, C
    Parra, M
    Nicolaides, KH
    [J]. OBSTETRICS AND GYNECOLOGY, 2000, 96 (04) : 559 - 564
  • [2] DULEY C, 1999, COCHRANE DATABASE SY
  • [3] SEVERE PRE-ECLAMPSIA - ANOTHER GREAT IMITATOR
    GOODLIN, RC
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 125 (06) : 747 - 753
  • [4] HEILMANN L, 1989, Z GEBURTSH PERINATOL, V193, P219
  • [5] Heyl W, 1997, CLIN HEMORHEOL MICRO, V17, P225
  • [6] Critical comparison of indices and threshold values for assessing placenta performance using Doppler ultrasound
    Joern, H
    Klein, A
    Kuehlwein, H
    Rath, W
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) : 1179 - 1183
  • [7] Joern H, 2000, CLIN HEMORHEOL MICRO, V22, P205
  • [8] Joern H, 2002, CLIN HEMORHEOL MICRO, V26, P277
  • [9] Non-invasive display and quantification of placental blood flow during pregnancy, IUGR and IUD
    Jörn, H
    Gerke, S
    Kahn, N
    Schmid-Schönbein, H
    Rath, W
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2004, 64 (06) : 605 - 611
  • [10] Influence of parameters on the visualisation and quantification of placental blood flow in normal pregnancy
    Jörn, H
    Wiertz, J
    Kahn, N
    Schwann, R
    Rath, W
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2004, 64 (04) : 387 - 394