An update on postrefractive surgery intraocular pressure determination

被引:5
作者
Yao, Wen-Jeng [1 ]
Crossan, Alessa Sook [1 ]
机构
[1] Albert Einstein Coll Med, Montefiore Med Ctr, Bronx, NY 10466 USA
关键词
corneal biomechanics; intraocular pressure; refractive surgery; IN-SITU KERATOMILEUSIS; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; LASER PHOTOREFRACTIVE KERATECTOMY; CORNEAL BIOMECHANICAL PROPERTIES; NONCONTACT TONOMETRY; THICKNESS; PNEUMOTONOMETRY; GLAUCOMA; EYES;
D O I
10.1097/ICU.0000000000000065
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review Due to alterations in corneal structure and biomechanics, intraocular pressure (IOP) measurement after refractive surgery has questionable accuracy. Numerous devices and techniques have been evaluated in the past decade. Whereas some methods clearly underestimate postoperative IOPs, other promising leads have emerged that are less affected by laser ablative procedures. Recent findings It is well established that Goldmann applanation tonometry (GAT) underestimates IOP after refractive surgery. The discussion on the accuracy of different techniques of IOP measurement after refractive surgery remains ongoing. Evidence suggests that techniques that are less reliant on corneal structure and biomechanics may provide less altered IOPs postoperatively. Therefore, devices such as Dynamic Contour Tonometry and tonopen may have great utility after laser ablative surgery. Summary GAT may not be the best method of measuring IOP after refractive surgery. Other devices may be superior to the GAT in providing more accurate IOP postoperatively. It is imperative that clinicians are aware of the possible inaccuracy of IOP acquisition after refractive surgery, in order to provide optimal monitoring for the development and progression of glaucoma.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 46 条
  • [1] The proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice
    Alvarez, TL
    Gollance, SA
    Thomas, GA
    Greene, RJ
    Marchetto, PM
    Moore, EJ
    Realini, T
    Liebmann, JM
    Ritch, R
    Lama, P
    Fechtner, RD
    [J]. OPHTHALMOLOGY, 2004, 111 (06) : 1077 - 1085
  • [2] Poor utility of intraocular pressure correction formulae in individual glaucoma and glaucoma suspect patients
    Ang, Ghee S.
    Nicholas, Simon
    Wells, Anthony P.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (02) : 111 - 118
  • [3] Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery
    Aristeidou, Antonios P.
    Labiris, Georgios
    Katsanos, Andreas
    Fanariotis, Michalis
    Foudoulakis, Nikitas C.
    Kozobolis, Vassilios P.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (05) : 767 - 773
  • [4] Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas
    Bourges, Jean-Louis
    Alfonsi, Nicolas
    Laliberte, Jean-Francois
    Chagnon, Miguel
    Renard, Gilles
    Legeais, Jean-Marc
    Brunette, Isabelle
    [J]. OPHTHALMOLOGY, 2009, 116 (11) : 2064 - 2071
  • [5] Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia
    Chatterjee, A
    Shah, S
    Bessant, DA
    Naroo, SA
    Doyle, SJ
    [J]. OPHTHALMOLOGY, 1997, 104 (03) : 355 - 359
  • [6] Corneal biomechanical measurements before and after laser in situ keratomileusis
    Chen, Michael C.
    Lee, Nancy
    Bourla, Nirit
    Hamilton, D. Rex
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) : 1886 - 1891
  • [7] Effect of corneal curvature and corneal thickness on the assessment of Intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery
    Cheng, ACK
    Fan, D
    Tang, E
    Lam, DSC
    [J]. CORNEA, 2006, 25 (01) : 26 - 28
  • [8] Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer
    Cheng, ACK
    Leung, DYL
    Cheung, EYY
    Fan, DSP
    Law, RWK
    Lam, DSC
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) : 153 - 157
  • [9] The influence of cornea properties on rebound tonometry
    Chui, Wan-sang
    Lam, Andrew
    Chen, Davie
    Chiu, Roger
    [J]. OPHTHALMOLOGY, 2008, 115 (01) : 80 - 84
  • [10] Tonometry after laser in situ keratomileusis treatment
    Duch, S
    Serra, A
    Castanera, J
    Abos, R
    Quintana, M
    [J]. JOURNAL OF GLAUCOMA, 2001, 10 (04) : 261 - 265