Fully automated thromboelastograph TEG 6s to measure anticoagulant effects of direct oral anticoagulants in healthy male volunteers

被引:51
作者
Artang, Ramin [1 ,2 ]
Anderson, Maren [1 ,3 ]
Nielsen, Jorn D. [2 ]
机构
[1] Essentia Hlth St Marys Heart & Vasc Ctr, 400 E Third St, Duluth, MN 55805 USA
[2] Univ Copenhagen, Bispebjerg Univ Hosp, Copenhagen, Denmark
[3] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
关键词
apixaban; dabigatran; direct oral anticoagulants; rivaroxaban; thromboelastography; RIVAROXABAN; COAGULATION; DABIGATRAN; APIXABAN; THROMBELASTOGRAPHY; REVERSAL;
D O I
10.1002/rth2.12206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The ability to assess the hemostatic effect of the direct oral anticoagulant (DOACs) may be valuable in clinical situations such as bleeding or thrombosis, before urgent surgery, or reversal of anticoagulation. We sought to assess the anticoagulant effect of DOACs with the new-generation fully automated thrombelastograph TEG 6s using resonance-frequency viscoelasticity measurements and disposable multichannel microfluidic cartridges. Methods: A single dose of oral dabigatran 150 mg, rivaroxaban 20 mg, or apixaban 5 mg was given to 9 healthy males. Phlebotomy was performed at 0, 1, and 3 hours after administration of DOAC. TEG parameters were measured using TEG (R) 6s. Concentrations of DOACs were measured using chromogenic assays. The TEG parameters were correlated to the DOAC concentrations. Results: The reaction time (R) demonstrated the strongest response to DOAC intake. There were no correlations between other TEG parameters and DOAC concentrations. Using the direct thrombin inhibitor (DTI) channel, R was significantly correlated with dabigatran levels (r = 0.94, P < 0.0001). Using the anti-factor Xa (AFXa) channel, R was significantly correlated with rivaroxaban and apixaban levels (r = 0.93 and r = 0.83, respectively; P < 0.0001 for both). R >2.5 minutes for dabigatran (DTI channel), >2.5 minutes for apixaban, and >1.8 minutes for rivaroxaban (AFXa channel) were associated with 100% sensitivity and >= 90% specificity to detect DOAC levels of >= 50 ng/mL. Conclusion: We have demonstrated that TEG (R) 6s R has significant correlation with DOAC blood concentrations and has potential for monitoring the DOAC's effect on hemostasis with reasonable sensitivity in the small sample analyzed. This novel technology is easy to use on a small volume of whole blood without requiring a specialized laboratory. Further study is warranted to correlate R with clinical outcomes.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 19 条
[1]   Measuring the activity of apixaban and rivaroxaban with rotational thrombelastometry [J].
Adelmann, Dieter ;
Wiegele, Marion ;
Wohlgemuth, Rudolf Karl ;
Koch, Stefan ;
Frantal, Sophie ;
Quehenberger, Peter ;
Scharbert, Gisela ;
Kozek-Langenecker, Sibylle ;
Schaden, Eva .
THROMBOSIS RESEARCH, 2014, 134 (04) :918-923
[2]   Assessment of the effect of direct oral anticoagulants dabigatran, rivaroxaban, and apixaban in healthy male volunteers using a thrombin generation assay [J].
Artang, Ramin ;
Anderson, Maren ;
Riley, Paul ;
Nielsen, Jorn D. .
RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2017, 1 (02) :194-201
[3]   MONITORING NOVEL ANTICOAGULANTS DABIGATRAN, RIVAROXABAN AND APIXABAN USING THROMBELASTOGRAPHY [J].
Artang, Ramin ;
Galloway, Gregg ;
Nielsen, Joern Dalsgaard .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) :A439-A439
[4]   Application of basic and composite thrombelastography parameters in monitoring of the antithrombotic effect of the low molecular weight heparin dalteparin: An in vivo study [J].
Artang R. ;
Frandsen N.J. ;
Nielsen J.D. .
Thrombosis Journal, 7 (1) :14
[5]  
Baglin T, 2013, J Thromb Haemost, DOI 10.1111/jth.12149
[6]   Determination of non-Vitamin K oral anticoagulant (NOAC) effects using a new-generation thrombelastography TEG 6s system [J].
Bliden, Kevin P. ;
Chaudhary, Rahul ;
Mohammed, Nafees ;
Muresan, Adina A. ;
Lopez-Espina, Carlos G. ;
Cohen, Eli ;
Raviv, Gabriel ;
Doubleday, Marc ;
Zaman, Fowzia ;
Mathew, Blessy ;
Tantry, Udaya S. ;
Gurbel, Paul A. .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2017, 43 (04) :437-445
[7]  
Chandler WL, 1995, SEMIN THROMB HEMOST, V21, P1
[8]   Reduction of the turn-around time for the measurement of rivaroxaban and apixaban: Assessment of the performance of a rapid centrifugation method [J].
Dincq, A. -S. ;
Lessire, S. ;
Pirard, G. ;
Siriez, R. ;
Guldenpfennig, M. ;
Baudar, J. ;
Favresse, J. ;
Douxfils, J. ;
Mullier, F. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (06) :E105-E108
[9]   Global coagulation tests: their applicability for measuring direct factor Xa- and thrombin inhibition and reversal of anticoagulation by prothrombin complex concentrate [J].
Dinkelaar, Jasper ;
Patiwael, Sanne ;
Harenberg, Job ;
Leyte, Anja ;
Brinkman, Herm Jan M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (11) :1615-1623
[10]   Laboratory testing in patients treated with direct oral anticoagulants: a practical guide for clinicians [J].
Douxfils, J. ;
Ageno, W. ;
Samama, C. -M. ;
Lessire, S. ;
ten Cate, H. ;
Verhamme, P. ;
Dogne, J. -M. ;
Mullier, F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2018, 16 (02) :209-219