Manipulator for magnetic resonance imaging guided interventions:: Design, prototype and feasibility

被引:9
作者
Christoforous, Eftychios G. [1 ,2 ,4 ]
Ozcan, Alpay [1 ,3 ]
Tsekos, Nikolaos V. [1 ,2 ,5 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, CB 8225,4525 Scott Ave, St Louis, MO 63110 USA
[2] Washington Univ, Cardiovascular Imaging Lab, St Louis, MO 63110 USA
[3] Washington Univ, Biomed MR Lab, St Louis, MO 63110 USA
[4] Washington Univ, Dept Elect & Syst Engn, St Louis, MO 63110 USA
[5] Washington Univ, Dept Biomed Engn, St Louis, MO 63110 USA
来源
2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10 | 2006年
关键词
medical robotics; image-guided interventions; magnetic resonance imaging; MRI-guidance;
D O I
10.1109/ROBOT.2006.1642289
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of this work is to develop a seven degree of freedom (DOF) remotely controlled manipulator to perform minimally invasive interventions with real-time magnetic resonance imaging (MRI) guidance inside clinical cylindrical scanners. Control of the device is based on MR images collected pre-operatively and in real-time during the procedure. A user interface fuses all sensor information for man-in-the-loop control. Stereotactic guidance uses multislice and/or three-dimensional MR images to set a trajectory of insertion. Free-handed (or manual) guidance uses a master/slave control device, which replicates the kinematics structure of the arm, to control its movement. The control software checks any motion of the manipulator whether it is within an allowable volume extracted from MR images. The device control is performed with a host/target computer configuration. The system is connected to the MR scanner to receive the MR images and send the coordinates of the end-effector for dynamic control of the imaged plane. The manipulator compatibility with the MR environment and image-guided maneuvering was tested on a 1.5 Tesla MR scanner.
引用
收藏
页码:3838 / +
页数:2
相关论文
共 19 条
  • [1] Chinzei K, 2001, Med Sci Monit, V7, P153
  • [2] DEBATIN JF, 1998, INTERVENTIONAL MAGNE
  • [3] Felden A, 2002, Biomed Tech (Berl), V47 Suppl 1 Pt 1, P2, DOI 10.1515/bmte.2002.47.s1a.2
  • [4] System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance
    Fichtinger, G
    DeWeese, TL
    Patriciu, A
    Tanacs, A
    Mazilu, D
    Anderson, JH
    Masamune, K
    Taylor, RH
    Stoianovici, D
    [J]. ACADEMIC RADIOLOGY, 2002, 9 (01) : 60 - 74
  • [5] Genesis of interventional MRI
    Jolesz, F
    Kahn, T
    Lufkin, R
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 2 - 2
  • [6] Interventional and intraoperative MRI: A general overview of the field
    Jolesz, FA
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 3 - 7
  • [7] Compatible instrumentation for intraoperative MRI: Expanding resources
    Jolesz, FA
    Morrison, PR
    Koran, SJ
    Kelley, RJ
    Hushek, SG
    Newman, RW
    Fried, MP
    Melzer, A
    Seibel, RMM
    Jalahej, H
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 8 - 11
  • [8] Jolesz FA, 2001, J MAGN RESON IMAGING, V13, P69, DOI 10.1002/1522-2586(200101)13:1<69::AID-JMRI1011>3.0.CO
  • [9] 2-2
  • [10] Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit
    Kaiser, WA
    Fischer, H
    Vagner, J
    Selig, M
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (08) : 513 - 519