Common Mode Voltage in case of Transformerless PV Inverters Connected to the Grid

被引:0
|
作者
Kerekes, T. [1 ]
Teodorescu, R. [2 ]
Liserre, M. [1 ]
机构
[1] Politecn Bari, Via E Orabona 4, I-70125 Bari, Italy
[2] Aalborg Univ, DK-9220 Aalborg, Denmark
来源
2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5 | 2008年
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For safety reasons grid connected PV systems include galvanic isolation. In case of transformerless inverters, the leakage ground current through the parasitic capacitance of the PV panels, can reach very high values. A common-mode model based on analytical approach is introduced, used to predict the common-mode behavior, at frequencies lower than 50kHz, of the selected topologies and to explain the influence of system imbalance on the leakage current. It will be demonstrated that the neutral inductance has a crucial influence on the leakage current. Finally experimental results will be shown for the NPC topology, emphasizing the low leakage current for the case of a grid connection without galvanic isolation.
引用
收藏
页码:2090 / +
页数:3
相关论文
共 50 条
  • [1] Transformerless Grid-Connected Converter for PV Plants with Constant Common Mode Voltage and Arbitrary Power Factor
    Barater, D.
    Buticchi, G.
    Lorenzani, E.
    Malori, V.
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 5756 - 5761
  • [2] Methodology for the optimal design of transformerless grid-connected PV inverters
    Koutroulis, E.
    Blaabjerg, F.
    IET POWER ELECTRONICS, 2012, 5 (08) : 1491 - 1499
  • [3] DC injection control for transformerless PV grid-connected inverters
    Wang, Bao-Cheng
    Guo, Xiao-Qiang
    Mei, Qiang
    Sun, Xiao-Feng
    Wu, Wei-Yang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (36): : 23 - 28
  • [4] Investigation of common-mode voltage and ground leakage current of grid-connected transformerless PV inverter topology
    Raji, Atanda K.
    Kahn, Mohamed T. E.
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2015, 26 (01) : 20 - 24
  • [5] Transformerless photovoltaic inverters connected to the grid
    Kerekes, T.
    Teodorescu, R.
    Borup, U.
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1733 - +
  • [6] Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability
    Koutroulis, Eftichios
    Blaabjerg, Frede
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 1959 - 1966
  • [7] Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability
    Koutroulis, Eftichios
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) : 325 - 335
  • [8] 240°-Clamped PWM Applied to Transformerless Grid Connected PV Converters With Reduced Common Mode Voltage and Superior Performance Metrics
    Qamar, Haleema
    Qamar, Hafsa
    Korada, Nikhil
    Ayyanar, Rajapandian
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2022, 3 : 153 - 167
  • [9] Novel Common-Mode Current Suppression Method in Transformerless PV Grid-Connected System
    Liu, Dongliang
    Zhu, Haoqi
    Zhao, Ruiguang
    APPLIED SCIENCES-BASEL, 2018, 8 (11):
  • [10] Single Carrier PWM Strategy for Grid Connected PV Transformerless Cascade Multilevel Inverters
    Vazquez, G.
    Rodriguez-Larios, L.
    Sosa, J. M.
    Martinez-Rodriguez, P. R.
    Valdez Fernandez, A. A.
    2018 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2018,