Effectiveness of grasping and duration of clamping using laparoscopic graspers

被引:52
作者
Heijnsdijk, EAM
Dankelman, J
Gouma, DJ
机构
[1] Delft Univ Technol, Fac Design Engn & Prod, Man Machine Syst Grp, NL-2628 CD Delft, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Surg, NL-1100 DE Amsterdam, Netherlands
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2002年 / 16卷 / 09期
关键词
laparoscopic instruments; tissue damage;
D O I
10.1007/s00464-001-9179-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Manipulating tissue with laparoscopic forceps is more difficult than using the hands. This study investigates the effectiveness of grasping and the duration or tissue-clamping using laparoscopic forceps. Methods: Video recordings of 10 laparoscopic colectomies and 15 cholecystectomies were analyzed using time-action analysis. Results: The results indicated that 62% of the grasping actions were successful: the tissue was clamped sufficiently to perform an action. Of all the clamping actions on the colon, 10% were repeated actions. On the gallbladder 7% were repeated actions. The bowel slipped out of the grasper in 7% of the clamping actions, whereas the gallbladder slipped in 17%. In 89%, the colon was clamped less than 1 min. The maximum clamping time was 7 min for the colon, and 55 min for the gallbladder. Conclusion: The low percentage of successful grasping actions indicates that the design of laparoscopic graspers is not optimal.
引用
收藏
页码:1329 / 1331
页数:3
相关论文
共 10 条
  • [1] Bannenberg JIG, 1994, MINIM INVAS THER S1, V3, P37
  • [2] High pressures are generated at the tip of laparoscopic graspers
    Cartmill, JA
    Shakeshaft, AJ
    Walsh, WR
    Martin, CJ
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1999, 69 (02): : 127 - 130
  • [3] Claus G P, 1995, Endosc Surg Allied Technol, V3, P210
  • [4] Sensitivity of laparoscopic dissectors - What can you feel?
    den Boer, KT
    Herder, JL
    Sjoerdsma, W
    Meijer, DW
    Gouma, DJ
    Stassen, HG
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (09): : 869 - 873
  • [5] ARE ATRAUMATIC BOWEL CLAMPS TRULY ATRAUMATIC
    HOENIG, DM
    CHROSTEK, CA
    WATT, D
    AMARAL, JF
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1994, 3 (02): : 95 - 98
  • [6] Errors enacted during endoscopic surgery - a human reliability analysis
    Joice, P
    Hanna, GB
    Cuschieri, A
    [J]. APPLIED ERGONOMICS, 1998, 29 (06) : 409 - 414
  • [7] Kimura T, 1996, SURG ENDOSC, V10, P888
  • [8] Grasper trauma during laparoscopic cholecystectomy
    Marucci, DD
    Shakeshaft, AJ
    Cartmill, JA
    Cox, MR
    Adams, SG
    Martin, CJ
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 2000, 70 (08): : 578 - 581
  • [9] Patkin M, 1995, J R Coll Surg Edinb, V40, P120
  • [10] Mechanism, management, and prevention of laparoscopic bowel injuries
    Schrenk, P
    Woisetschlager, R
    Rieger, R
    Wayand, W
    [J]. GASTROINTESTINAL ENDOSCOPY, 1996, 43 (06) : 572 - 574