Facile analysis of metabolites by capillary electrophoresis coupled to matrix-assisted laser desorption/ionization mass spectrometry using target plates with polysilazane nanocoating and grooves

被引:22
作者
Amantonico, Andrea [1 ]
Urban, Pawel L. [1 ]
Zenobi, Renato [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
MALDI-TOF; SEPARATION; PROTEINS; MS; CE; IDENTIFICATION; PEPTIDES;
D O I
10.1039/b907039g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present an inexpensive method and apparatus for the deposition of analytes separated by capillary electrophoresis (CE) onto a custom-designed matrix-assisted laser desorption/ionization (MALDI) target plate. This dedicated CE-MALDI plate is coated with an omniphobic polysilazane nanocoating and has an array of parallel grooves acting as recipients of the separation effluent. The 3-D pattern in the top layer of the coated plate greatly improves loading of the matrix solution prior to separation and facilitates deposition of the separated species. We demonstrate application of this straightforward protocol to the analysis of metabolites from the central metabolic pathway in a complex biological sample spiked with small molecule standards.
引用
收藏
页码:1536 / 1540
页数:5
相关论文
共 32 条
  • [1] AMANTONICO A, 2009, CHIMIA, DOI DOI 10.2533/CHIMIA.2009.1
  • [2] Mass spectrometric method for analyzing metabolites in yeast with single cell sensitivity
    Amantonico, Andrea
    Oh, Joo Yeon
    Sobek, Jens
    Heinemann, Matthias
    Zenobi, Renato
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (29) : 5382 - 5385
  • [3] Biochemistry's new look
    Blow, Nathan
    [J]. NATURE, 2008, 455 (7213) : 697 - 700
  • [4] Negative mode sheathless capillary electrophoresis electrospray ionization-mass spectrometry for metabolite analysis of prokaryotes
    Edwards, JL
    Chisolm, CN
    Shackman, JG
    Kennedy, RT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) : 80 - 88
  • [5] Metabolomic analysis of eukaryotic tissue and prokaryotes using negative mode MALDI time-of-flight mass spectrometry
    Edwards, JL
    Kennedy, RT
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2201 - 2209
  • [6] Signal amplification using "spot on-a-chip" technology for the identification of proteins via MALDI-TOF MS
    Ekström, S
    Ericsson, D
    Önnerfjord, P
    Bengtsson, M
    Nilsson, J
    Marko-Varga, G
    Laurell, T
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 214 - 219
  • [7] High-speed biomarker identification utilizing porous silicon nanovial arrays and MALDI-TOF mass spectrometry
    Finnskog, D
    Jaras, K
    Ressine, A
    Malm, J
    Marko-Varga, G
    Lilja, H
    Laurell, T
    [J]. ELECTROPHORESIS, 2006, 27 (5-6) : 1093 - 1103
  • [8] Novel Three-Dimensional MALDI Plate for Interfacing High-Capacity LC Separations with MALDI-TOF
    Hattan, Stephen J.
    Vestal, Marvin L.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9115 - 9123
  • [9] Progress in capillary electrophoresis coupled to matrix-assisted laser desorption/ionization - time of flight mass spectrometry
    Huck, CW
    Bakry, R
    Huber, LA
    Bonn, GK
    [J]. ELECTROPHORESIS, 2006, 27 (11) : 2063 - 2074
  • [10] Capillary electrophoretic separation and fractionation of hydrophobic peptides onto a pre-structured matrix assisted laser desorption/ionization target for mass spectrometric analysis
    Jacksén, J
    Redeby, T
    Emmer, Å
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (02) : 288 - 295