EVALUATION OF THE EFFECTS OF PROCESSING DELAYS AND PROTECTIVE PLASTIC CASES ON IMAGE QUALITY OF A PHOTOSTIMULABLE PHOSPHOR PLATE SYSTEM

被引:6
作者
Bramante, Clovis Monteiro [1 ]
Bramante, Alexandre Silva [2 ]
de Souza, Rogerio Emilio [3 ]
Moraes, Ivaldo Gomes
Bernardineli, Norberti
Garcia, Roberto Brandao
机构
[1] USP, Fac Odontol Bauru, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, BR-17012901 Bauru, SP, Brazil
[2] Brasiliense Sch Dent, Brasilia, DF, Brazil
[3] FACIMP, Sch Dent, Imperatriz, MA, Brazil
关键词
Radiography; Digital images; Phosphor storage plates; Digora;
D O I
10.1590/S1678-77572008000500009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This ex vivo study evaluated the quality of digital radiographic images obtained with the photostimulable phosphor plate system (Digora) according to the processing delay and maintenance of optical plates in either opaque (supplied with the system) or transparent protective plastic cases during this period. Five radiographs were obtained from the mandibular molar region of a dry human mandible using optical plates. These plates were placed in the protective plastic cases before obtaining the radiographs and were processed immediately or after processing delays of 5, 60 and 120 min, when the case was removed. The results revealed a reduction in image quality when processing was delay 120 min compared to the other times. The opaque case provided better protection to the sensor than the transparent case. In conclusion, a 120-min processing delay for the Digora system caused a reduction in image quality, yet without interfering with the quality of diagnosis. The opaque case supplied by the system's manufacturer provided better protection to the optical plate than the transparent case.
引用
收藏
页码:350 / 354
页数:5
相关论文
共 18 条
[1]   Degradation of storage phosphor images due to scanning delay [J].
Akdeniz, BG ;
Gröndahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (02) :74-77
[2]   Effect of delayed scanning of storage phosphor plates [J].
Akdeniz, BG ;
Gröndahl, HG ;
Kose, T .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (05) :603-607
[3]  
Bedard Aurelija, 2004, J Contemp Dent Pract, V5, P57
[4]   Diagnosis of Bone Defects by Conventional, Digital and Helicoidal Tomography [J].
Bramante, Alexandre S. ;
Bramante, Clovis M. ;
Bernardineli, Norberti ;
de Moraes, Ivaldo Gomes ;
Garcia, Roberto Brandao .
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2007, 48 (01) :15-21
[5]   The imaging performance of a storage phosphor system for dental radiography [J].
Brettle, DS ;
Workman, A ;
Ellwood, RP ;
Launders, JH ;
Horner, K ;
Davies, RM .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :256-261
[6]   RADIOGRAPHIC DETERMINATION OF CANAL LENGTH - DIRECT DIGITAL RADIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY [J].
HEDRICK, RT ;
DOVE, SB ;
PETERS, DD ;
MCDAVID, WD .
JOURNAL OF ENDODONTICS, 1994, 20 (07) :320-326
[7]   Storage-phosphor computed radiography versus film radiography in the detection of pathologic periradicular bone loss in cadavers [J].
Holtzmann, DJ ;
Johnson, WT ;
Southard, TE ;
Khademi, JA ;
Chang, PJ ;
Rivera, EM .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (01) :90-97
[8]   Comparison of a photostimulable phosphor system with film for dental radiology [J].
Huda, W ;
Rill, LN ;
Benn, DK ;
Pettigrew, JC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 83 (06) :725-731
[9]   Intra-oral storage phosphor and conventional radiography in the assessment of alveolar bone structures [J].
Kaeppler, G ;
Vogel, A ;
Axmann-Krcmar, D .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (06) :362-367
[10]   Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions [J].
Martins, MGBQ ;
Neto, FH ;
Whaites, EJ .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (03) :186-190