Changes in blood ion levels after removal of metal-on-metal hip replacements 16 patients followed for 0-12 months

被引:21
作者
Durrani, Salim K. [1 ]
Noble, Philip C. [1 ,2 ]
Sampson, Barry [3 ]
Panetta, Therese [3 ]
Liddle, Alexander D. [3 ]
Sabah, Shiraz A. [3 ]
Chan, Newton K. [1 ]
Skinner, John A. [4 ]
Hart, Alister J. [4 ]
机构
[1] Inst Orthoped Res & Educ, Houston, TX 77030 USA
[2] Baylor Coll Med, Houston, TX 77030 USA
[3] Univ London Imperial Coll Sci Technol & Med, London, England
[4] Royal Natl Orthopaed Hosp, London W1N 6AD, England
关键词
RESURFACING ARTHROPLASTY; ACTIVE PATIENTS; COBALT; CHROMIUM; SERUM; FAILURE; YOUNG; IMPLANTS; SURFACES; TISSUES;
D O I
10.3109/17453674.2014.913223
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - In patients with metal-on-metal (MoM) hip prostheses, pain and joint effusions may be associated with elevated blood levels of cobalt and chromium ions. Since little is known about the kinetics of metal ion clearance from the body and the rate of resolution of elevated blood ion levels, we examined the time course of cobalt and chromium ion levels after revision of MoM hip replacements. Patients and methods - We included 16 patients (13 female) who underwent revision of a painful MoM hip (large diameter, modern bearing) without fracture or infection, and who had a minimum of 4 blood metal ion measurements over an average period of 6.1 (0-12) months after revision. Results - Average blood ion concentrations at the time of revision were 22 ppb for chromium and 43 ppb for cobalt. The change in ion levels after revision surgery varied extensively between patients. In many cases, over the second and third months after revision surgery ion levels decreased to 50% of the values measured at revision. Decay of chromium levels occurred more slowly than decay of cobalt levels, with a 9% lag in return to normal levels. The rate of decay of both metals followed second-order (exponential) kinetics more closely than first-order (linear) kinetics. Interpretation - The elimination of cobalt and chromium from the blood of patients who have undergone revision of painful MoM hip arthroplasties follows an exponential decay curve with a half-life of approximately 50 days. Elevated blood levels of cobalt and chromium ions can persist for at least 1 year after revision, especially in patients with high levels of exposure.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 34 条
[1]   Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[2]   Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips [J].
Campbell, Pat ;
Ebramzadeh, Edward ;
Nelson, Scott ;
Takamura, Karren ;
De Smet, Koen ;
Amstutz, Harlan C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2321-2327
[3]   WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[4]   Early Markers of Nephrotoxicity in Patients With Metal-on-metal Hip Arthroplasty [J].
Corradi, Massimo ;
Daniel, Joseph ;
Ziaee, Hena ;
Alinovi, Rossella ;
Mutti, Antonio ;
McMinn, Derek J. W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) :1651-1659
[5]   Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty - Four-year results of a prospective longitudinal study [J].
Daniel, J. ;
Ziaee, H. ;
Pradhan, C. ;
Pynsent, P. B. ;
McMinn, D. J. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02) :169-173
[6]   Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings [J].
Daniel, J. ;
Ziaee, H. ;
Pradhan, C. ;
McMinn, D. J. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (02) :176-179
[7]   Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing [J].
de Smet, K. ;
de Haan, R. ;
Calistri, A. ;
Campbell, P. A. ;
Ebramzadeh, E. ;
Pattyn, C. ;
Gill, H. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :202-208
[8]   Metal ion levels after metal-on-metal proximal femoral replacements - A 30-year follow-up [J].
Dunstan, E ;
Sanghrajka, AP ;
Tilley, S ;
Unwin, P ;
Blunn, G ;
Cannon, SR ;
Briggs, TWR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05) :628-631
[9]   Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement [J].
Hart, A. J. ;
Sabah, S. A. ;
Bandi, A. S. ;
Maggiore, P. ;
Tarassoli, P. ;
Sampson, B. ;
Skinner, J. A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10) :1308-1313
[10]   The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings A PROSPECTIVE, CT-BASED STUDY [J].
Hart, A. J. ;
Ilo, K. ;
Underwood, R. ;
Cann, P. ;
Henckel, J. ;
Lewis, A. ;
Cobb, J. ;
Skinner, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03) :315-320