Influence of droplet size, capillary-cone distance and selected instrumental parameters for the analysis of noncovalent protein-ligand complexes by nano-electrospray ionization mass spectrometry

被引:46
作者
Benkestock, K [1 ]
Sundqvist, G
Edlund, PO
Roeraade, J
机构
[1] Biovitrum AB, Dept Struct Chem, SE-11276 Stockholm, Sweden
[2] Royal Inst Technol, Dept Analyt Chem, SE-10044 Stockholm, Sweden
[3] Biovitrum AB, Dept Analyt Sci, SE-11276 Stockholm, Sweden
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 09期
关键词
nano-electrospray ionization; noncovalent complexes; droplet size; capillary-cone distance; H-FABP; RNAse;
D O I
10.1002/jms.685
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It has been suggested in the literature that nano-electrospray ionization (nano-ESI) mass spectrometry better reflects the equilibrium between complex and free protein in solution than pneumatically assisted electrospray ionization (ESI) in noncovalent interaction studies. However, no systematic studies of the effects of ionization conditions have been performed to support this statement. In the present work, different instrumental and sample-derived parameters affecting the stability of noncovalent complexes during analysis by nano-ESI were investigated. In general, increased values of parameters such as drying gas flow-rate, ion-source temperature, capillary tip voltage and buffer concentration lead to a dissociation of ribonuclease A (RNAse)-cytidine 2'-monophosphate (CMP) and cytidine 5'-triphosphate (CTP) complexes. The size of the electrosprayed droplets was shown to be an important issue. Increasing the capillary to cone distance yielded an increased complex to free protein ratio when a hydrophilic ligand was present and the reverse effect was obtained with a hydrophobic ligand. Important in this regard is the degree of sampling of ions originating from late-generation residue droplets, that is, ions present in the droplet bulk. Sampling of these ions increases with longer capillary-cone distance (flight time). Furthermore, when the sample flow-rate was increased by increasing the capillary internal tip i.d. from 4 to 30 mum, a decreased complex to free protein ratio for the RNAse-CTP system was observed. This behavior was consistent with the change in surface to volume ratio for flow-rates between 2 and 100 nl min(-1). Finally, polarity switching between positive and negative ion modes gave a higher complex to free protein ratio when the ligand and the protein had the same polarity. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1059 / 1067
页数:9
相关论文
共 38 条
  • [1] Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins
    Beck, JL
    Colgrave, ML
    Ralph, SF
    Sheil, MM
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (02) : 61 - 87
  • [2] Automated nano-electrospray mass spectrometry for protein-ligand screening by noncovalent interaction applied to human H-FABP and A-FABP
    Benkestock, K
    Van Pelt, CK
    Åkerud, T
    Sterling, A
    Edlund, PO
    Roeraade, J
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (03) : 247 - 256
  • [3] On-line microdialysis for enhanced resolution and sensitivity during electrospray mass spectrometry of non-covalent complexes and competitive binding studies
    Benkestock, K
    Edlund, PO
    Roeraade, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (21) : 2054 - 2059
  • [4] In-line desalting mass spectrometry for the study of noncovalent biological complexes
    Cavanagh, J
    Benson, LM
    Thompson, R
    Naylor, S
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3281 - 3286
  • [5] USING ELECTROSPRAY-IONIZATION FTICR MASS-SPECTROMETRY TO STUDY COMPETITIVE-BINDING OF INHIBITORS TO CARBONIC-ANHYDRASE
    CHENG, XH
    CHEN, RD
    BRUCE, JE
    SCHWARTZ, BL
    ANDERSON, GA
    HOFSTADLER, SA
    GALE, DC
    SMITH, RD
    GAO, JM
    SIGAL, GB
    MAMMEN, M
    WHITESIDES, GM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (34) : 8859 - 8860
  • [6] Cole R.B., 1997, Electrospray Ionization Mass Spectrometry
  • [7] Quantitative determination of noncovalent binding interactions using soft ionization mass spectrometry
    Daniel, JM
    Friess, SD
    Rajagopalan, S
    Wendt, S
    Zenobi, R
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 216 (01) : 1 - 27
  • [8] THE CURRENT EMITTED BY HIGHLY CONDUCTING TAYLOR CONES
    DELAMORA, JF
    LOSCERTALES, IG
    [J]. JOURNAL OF FLUID MECHANICS, 1994, 260 : 155 - 184
  • [9] Advantages and drawbacks of nanospray for studying noncovalent protein-DNA complexes by mass spectrometry
    Gabelica, V
    Vreuls, C
    Filée, P
    Duval, V
    Joris, B
    De Pauw, E
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) : 1723 - 1728
  • [10] OBSERVATION OF NONCOVALENT ENZYME SUBSTRATE AND ENZYME PRODUCT COMPLEXES BY ION-SPRAY MASS-SPECTROMETRY
    GANEM, B
    LI, YT
    HENION, JD
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (20) : 7818 - 7819