The Leukocyte Esterase Test Strip Is a Poor Rule-Out Test for Periprosthetic Joint Infection

被引:14
作者
Deirmengian, Carl A.
Liang, Lihua
Rosenberger, John P.
Joaquim, Tony R.
Gould, Martin R.
Citrano, Patrick A.
Kardos, Keith W.
机构
[1] Department of Orthopaedic Surgery, The Rothman Institute, Thomas Jefferson University, Philadelphia, Pennsylvania
[2] CD Diagnostics, Zimmer Biomet, Claymont, Delaware
关键词
leukocyte esterase test strip; PJI; arthroplasty; synovial fluid; neutrophil elastase; diagnostic tests; REAGENT STRIPS; SYNOVIAL-FLUID; DIAGNOSIS; ARTHROPLASTY;
D O I
10.1016/j.arth.2018.03.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The urinary leukocyte esterase (LE) test strip has been suggested as a good screening test for periprosthetic joint infection (PJI). The purpose of this study is to compare the diagnostic profile of LE assays from different manufacturers and determine whether the LE test strip is a good rule-out test. Methods: Synovial fluid samples (N = 344), sent to 1 laboratory for PJI testing, were used in this prospective study. Four different tests for synovial fluid LE were simultaneously evaluated for their performance in detecting white blood cell (WBC) positive samples (>3000 cells/mu L). Results: Both neutrophil elastase immunoassays demonstrated greater sensitivity than urinary LE test strips (92.0% and 90.8% vs 72.4% and 80.3%; all P < 0.011). Fifty-three percent of false-negative urinary LE test strip results clearly missed the presence of elevated levels of synovial fluid LE. Invalid urinary LE test strip results were 4-fold more likely among WBC (+) compared with WBC (-) samples (27.0% vs 6.8%; P < 0.0001). The combined failure to detect an elevated WBC count, because of either false-negative or invalid results, was 47.1% and 41.4% for the Roche and Siemens test strips, respectively. Conclusions: This study agrees with the existing literature demonstrating that the LE test strips are among the lowest sensitivity tests for PJI. The urinary LE tests strips should not be used to rule-out PJI, as they often fail to detect abundant levels of LE in synovial fluid. Instead, it is more appropriate to use the (++) LE test strip result as a secondary confirmatory rule-in test for PJI because of its high specificity. (C) 2018 The Authors. Published by Elsevier Inc.
引用
收藏
页码:2571 / 2574
页数:4
相关论文
共 12 条
[1]  
Aggarwal VK, 2013, J ARTHROPLASTY, V28, P193, DOI [10.1016/j.arth.2012.06.023, 10.1016/j.arth.2013.09.028]
[2]   The Alpha-defensin Test for Periprosthetic Joint Infection Outperforms the Leukocyte Esterase Test Strip [J].
Deirmengian, Carl ;
Kardos, Keith ;
Kilmartin, Patrick ;
Cameron, Alexander ;
Schiller, Kevin ;
Booth, Robert E., Jr. ;
Parvizi, Javad .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) :198-203
[3]   Excluding infections in arthroplasty using leucocyte esterase test [J].
Guenther, Daniel ;
Kokenge, Thomas ;
Jacobs, Oliver ;
Omar, Mohamed ;
Krettek, Christian ;
Gehrke, Thorsten ;
Kendoff, Daniel ;
Haasper, Carl .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (11) :2385-2390
[4]   The Leukocyte Esterase Strip Test has Practical Value for Diagnosing Periprosthetic Joint Infection After Total Knee Arthroplasty: A Multicenter Study [J].
Koh, In J. ;
Han, Seung B. ;
In, Yong ;
Oh, Kwang J. ;
Lee, Dae H. ;
Kim, Tae K. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (11) :3519-3523
[5]   Comparison of Leukocyte Esterase Testing of Synovial Fluid with Synovial Histology for the Diagnosis of Periprosthetic Joint Infection [J].
Li, Rui ;
Li, Xiang ;
Yu, Baozhan ;
Li, Xin ;
Song, Xinggui ;
Li, Heng ;
Xu, Chi ;
Chen, Jiying .
MEDICAL SCIENCE MONITOR, 2017, 23 :4440-4446
[6]  
Parvizi J, 2011, J BONE JOINT SURG AM, V93A, P2242, DOI [10.2106/JBJS.J.01413, 10.2106/JBJSJ.01413]
[7]   Use of leucocyte esterase reagent strips in the diagnosis or exclusion of prosthetic joint infection [J].
Shafafy, R. ;
McClatchie, W. ;
Chettiar, K. ;
Gill, K. ;
Hargrove, R. ;
Sturridge, S. ;
Guyot, A. .
BONE & JOINT JOURNAL, 2015, 97B (09) :1232-1236
[8]   Diagnosing Periprosthetic Joint Infection: And the Winner Is? [J].
Shahi, Alisina ;
Tan, Timothy L. ;
Kheir, Michael M. ;
Tan, Dean D. ;
Parvizi, Javad .
JOURNAL OF ARTHROPLASTY, 2017, 32 (09) :S232-S235
[9]   Leukocyte Esterase Strip Test: Matched for Musculoskeletal Infection Society Criteria [J].
Tischler, Eric H. ;
Cavanaugh, Priscilla K. ;
Parvizi, Javad .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (22) :1917-1920
[10]   Leukocyte Esterase as a Biomarker in the Diagnosis of Periprosthetic Joint Infection [J].
Wang, Chi ;
Li, Rui ;
Wang, Qi ;
Duan, Jinyan ;
Wang, Chengbin .
MEDICAL SCIENCE MONITOR, 2017, 23 :353-358