The Teller Acuity Cards Are Effective in Detecting Amblyopia

被引:25
|
作者
Drover, James R. [1 ]
Wyatt, Lauren M.
Stager, David R. [2 ]
Birch, Eileen E. [2 ]
机构
[1] Mem Univ Newfoundland, Dept Psychol, St John, NF A1B 3X9, Canada
[2] Univ Texas SW Med Ctr Dallas, Dept Ophthalmol, Dallas, TX 75390 USA
关键词
infant; vision; amblyopia; visual acuity; grating acuity; VISUAL-ACUITY; RECOGNITION ACUITIES; PEDIATRIC-PATIENTS; CHILDREN; INFANTS; RELIABILITY; STRABISMUS;
D O I
10.1097/OPX.0b013e3181a523a3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Detection of amblyopia in infants and toddlers is difficult because the current clinical standard for this age group, fixation preference, is inaccurate. Although grating acuity represents an alternative, studies of preschoolers and schoolchildren report that it is not equivalent to the gold standard optotype acuity. Here, we examine whether the Teller Acuity Cards (TAC) can detect amblyopia effectively by testing children old enough (7.8 +/- 3.6 years) to complete optotype acuity testing. Methods. Grating acuity was assessed monocularly in 45 patients with unilateral amblyopia, 44 patients at risk for amblyopia, and 37 children with no known vision disorders. Each child's grating acuity was classified as normal/abnormal based on age-appropriate norms. These classifications were compared with formal amblyopia diagnoses. Results. Grating acuity was finer than optotype acuity among amblyopic eyes (medians: 0.28 vs. 0.40 logMAR, respectively, p < 0.0001) but not among fellow eyes (medians: 0.03 vs. 0.10 logMAR, respectively, p = 0.36). The optotype acuity-grating acuity discrepancy among amblyopic eyes was larger for cases of severe amblyopia than for moderate amblyopia (means: 0.64 vs. 0.18 logMAR, respectively, p = 0.0001). Nevertheless, most cases of amblyopia were detected successfully by the TAC, yielding a sensitivity of 80%. Furthermore, grating acuity was relatively sensitive to all amblyopia subtypes (69 to 89%) and levels of severity (79 to 83%). Conclusions. Although grating acuity is finer than optotype acuity in amblyopic eyes, most children with amblyopia were identified correctly suggesting that grating acuity is an effective clinical alternative for detecting amblyopia. (Optom Vis Sci 2009;86:755-759)
引用
收藏
页码:755 / 759
页数:5
相关论文
共 50 条
  • [1] ASSESSMENT OF VISUAL-ACUITY WITH TELLER CARDS - EFFICIENT SCREENING FOR AMBLYOPIA IN INFANTS
    SPEEGSCHATZ, C
    REZAIFUIA, F
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1995, 18 (8-9): : 510 - 515
  • [2] Acuity norms of infants by clinical application of Teller Acuity Cards
    Grunewald, SM
    Mayer, UM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (06) : 376 - 383
  • [3] Visual evoked potential-based acuity assessment: overestimation in amblyopia
    Wenner, Yaroslava
    Heinrich, Sven P.
    Beisse, Christina
    Fuchs, Antje
    Bach, Michael
    DOCUMENTA OPHTHALMOLOGICA, 2014, 128 (03) : 191 - 200
  • [4] Assessment of Visual Acuity in Patients with Dementia using Teller Acuity Cards
    Froiman, Priscila
    Correa Dantas, Paulo
    STRABISMUS, 2013, 21 (02) : 93 - 97
  • [5] MONOCULAR ACUITY NORMS FOR THE TELLER ACUITY CARDS BETWEEN AGES ONE MONTH AND 4 YEARS
    MAYER, DL
    BEISER, AS
    WARNER, AF
    PRATT, EM
    RAYE, KN
    LANG, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (03) : 671 - 685
  • [6] Detection of Amblyopia Using Sweep VEP Vernier and Grating Acuity
    Hou, Chuan
    Good, William V.
    Norcia, Anthony M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1435 - 1442
  • [7] Visual acuity in the first two years of life in healthy term newborns: an experience with the Teller acuity cards
    Cavallini, A
    Fazzi, E
    Viviani, V
    Astori, MG
    Zaverio, S
    Bianchi, PE
    Lanzi, G
    FUNCTIONAL NEUROLOGY, 2002, 17 (02) : 87 - 92
  • [8] TELLER ACUITY CARDS FOR TESTING VISUAL DEVELOPMENT AND THE EFFECTS OF EXPERIMENTAL MANIPULATION IN MACAQUES
    SIRETEANU, R
    KATZ, B
    MOHN, G
    VITALDURAND, F
    CLINICAL VISION SCIENCES, 1992, 7 (02): : 107 - 117
  • [9] INTEROBSERVER AGREEMENT FOR MEASUREMENT OF GRATING ACUITY AND INTEROCULAR ACUITY DIFFERENCES WITH THE TELLER ACUITY CARD PROCEDURE
    MASH, C
    DOBSON, V
    CARPENTER, N
    VISION RESEARCH, 1995, 35 (02) : 303 - 312
  • [10] Visual acuity in the first year of life in healthy term newborn: An experience with the Teller Acuity Cards
    Fazzi, E
    Cavallini, A
    Viviani, V
    Astori, MG
    Zaverio, S
    Guglielmino, CR
    Lanzi, G
    RIVISTA ITALIANA DI PEDIATRIA-ITALIAN JOURNAL OF PEDIATRICS, 1996, 22 (01): : 67 - 73