Multi-task autoencoder based classification-regression model for patient-specific VMAT QA

被引:31
|
作者
Wang, Le [1 ,2 ,4 ]
Li, Jiaqi [3 ,5 ]
Zhang, Shuming [3 ]
Zhang, Xile [3 ]
Zhang, Qilin [3 ]
Chan, Maria F. [6 ]
Yang, Ruijie [3 ]
Sui, Jing [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Brainnetome Ctr, Beijing, Peoples R China
[2] Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing, Peoples R China
[3] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[4] Chinese Acad Sci, Univ Chinese Acad Sci, CAS Ctr Excellence Brain Sci & Intelligence Techn, Inst Automat, Beijing, Peoples R China
[5] Capital Med Univ, Beijing Childrens Hosp, Beijing, Peoples R China
[6] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
基金
中国国家自然科学基金;
关键词
VMAT QA; patient-specific QA; deep learning; radiotherapy; QUALITY-ASSURANCE; RADIOMIC ANALYSIS; IMRT; MODULATION; COMPLEXITY; RADIOTHERAPY; RAPIDARC; BEAMS;
D O I
10.1088/1361-6560/abb31c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific quality assurance (PSQA) of volumetric modulated arc therapy (VMAT) to assure accurate treatment delivery is resource-intensive and time-consuming. Recently, machine learning has been increasingly investigated in PSQA results prediction. However, the classification performance of models at different criteria needs further improvement and clinical validation (CV), especially for predicting plans with low gamma passing rates (GPRs). In this study, we developed and validated a novel multi-task model called autoencoder based classification-regression (ACLR) for VMAT PSQA. The classification and regression were integrated into one model, both parts were trained alternatively while minimizing a defined loss function. The classification was used as an intermediate result to improve the regression accuracy. Different tasks of GPRs prediction and classification based on different criteria were trained simultaneously. Balanced sampling techniques were used to improve the prediction accuracy and classification sensitivity for the unbalanced VMAT plans. Fifty-four metrics were selected as inputs to describe the plan modulation-complexity and delivery-characteristics, while the outputs were PSQA GPRs. A total of 426 clinically delivered VMAT plans were used for technical validation (TV), and another 150 VMAT plans were used for CV to evaluate the generalization performance of the model. The ACLR performance was compared with the Poisson Lasso (PL) model and found significant improvement in prediction accuracy. In TV, the absolute prediction error (APE) of ACLR was 1.76%, 2.60%, and 4.66% at 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively; whereas the APE of PL was 2.10%, 3.04%, and 5.29% at 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively. No significant difference was found between CV and TV in prediction accuracy. ACLR model set with 3%/3 mm can achieve 100% sensitivity and 83% specificity. The ACLR model could classify the unbalanced VMAT QA results accurately, and it can be readily applied in clinical practice for virtual VMAT QA.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Unifying gamma passing rates in patient-specific QA for VMAT lung cancer treatment based on data assimilation
    Ono, Tomohiro
    Adachi, Takanori
    Hirashima, Hideaki
    Iramina, Hiraku
    Kishi, Noriko
    Matsuo, Yukinori
    Nakamura, Mitsuhiro
    Mizowaki, Takashi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1337 - 1348
  • [12] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1600 - 1612
  • [13] Assessment of radiobiological metrics applied to patient-specific QA process of VMAT prostate treatments
    Clemente-Gutierrez, Francisco
    Perez-Vara, Consuelo
    Clavo-Herranz, Maria H.
    Lopez-Carrizosa, Concepcion
    Perez-Regadera, Jose
    Ibanez-Villoslada, Carmen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 341 - 367
  • [14] Predicting VMAT patient-specific QA results using a support vector classifier trained on treatment plan characteristics and linac QC metrics
    Granville, Dal A.
    Sutherland, Justin G.
    Belec, Jason G.
    La Russa, Daniel J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09)
  • [15] Evaluation of a 2D detector array for patient-specific VMAT QA with different setups
    Boggula, Ramesh
    Birkner, Mattias
    Lohr, Frank
    Steil, Volker
    Wenz, Frederik
    Wertz, Hansjoerg
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) : 7163 - 7177
  • [16] A single-optical kernel for a phosphor-screen-based geometric QA system (RavenQA™) as a tool for patient-specific IMRT/VMAT QA
    Lee, Minsik
    Ding, Kai
    Yi, ByongYong
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (20)
  • [17] Evaluation of prediction and classification performances in different machine learning models for patient-specific quality assurance of head-and-neck VMAT plans
    Kusunoki, Terufumi
    Hatanaka, Shogo
    Hariu, Masatsugu
    Kusano, Yohsuke
    Yoshida, Daisaku
    Katoh, Hiroyuki
    Shimbo, Munefumi
    Takahashi, Takeo
    MEDICAL PHYSICS, 2022, 49 (01) : 727 - 741
  • [18] Use of electronic portal imaging devices for pre-treatment and in vivo dosimetry patient-specific IMRT and VMAT QA: Report of AAPM Task Group 307
    Dogan, Nesrin
    Mijnheer, Ben. J.
    Padgett, Kyle
    Nalichowski, Adrian
    Wu, Chuan
    Nyflot, Matthew. J.
    Olch, Arthur. J.
    Papanikolaou, Niko
    Shi, Jie
    Holmes, Shannon. M.
    Moran, Jean
    Greer, Peter. B.
    MEDICAL PHYSICS, 2023, 50 (08) : E865 - E903
  • [19] Predicting the error magnitude in patient-specific QA during radiotherapy based on ResNet
    Huang, Ying
    Pi, Yifei
    Ma, Kui
    Miao, Xiaojuan
    Fu, Sichao
    Feng, Aihui
    Duan, Yanhua
    Kong, Qing
    Zhuo, Weihai
    Xu, Zhiyong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 797 - 807
  • [20] Error detection sensitivity test using complex errors on three patient-specific VMAT QA systems
    Thongsawad, S.
    Srisatit, S.
    Fuangrod, T.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE, 2019, 1285