Electrocatalytic oxidation and highly selective voltammetric determination of L-cysteine at the surface of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon paste electrode

被引:92
作者
Raoof, Jahan-Bakhsh [1 ]
Ojani, Reza [1 ]
Beitollahi, Hadi [1 ]
Hosseinzadeh, Rahman [1 ]
机构
[1] Mazandaran Univ, Fac Basic Sci, Dept Chem, Electroanalyt Chem Res Lab, Babol Sar, Iran
关键词
D O I
10.2116/analsci.22.1213
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode (CPE) chemically modified with 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone (4-FEPEMCPE) was employed to study the electrocatalytic oxidation Of L-cysteine using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry as diagnostic techniques. The diffusion coefficient (D 7.863 x 10(-6) cm(2) s(-1)) Of L-Cysteine was also estimated using chronoamperometry. The electron-transfer coefficient, a 0.40), for L-Cysteine at the surface of 4-FEPEMCPE was determined using cyclic voltammetry technique. It was found that under an optimum pH (= 7.00), the oxidation Of L-Cysteine at the surface of such an electrode occurred at a potential of about 350 mV less positive than that of an unmodified CPE. The catalytic oxidation peak currents represented a linear dependence on the L-Cysteine concentration. Linear analytical curves were obtained in the ranges of 9.0 x 10(-5) - 4.9 x 10(-3) M and 2.0 x 10(-5) - 2.8 X 10(-3) M of L-cysteine with correlation coefficients of 0.9981 and 0.9982 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2 sigma) were determined to be 9.9 X 10(-6) M and 5 x 10(-6) M with cyclic voltammetry and differential pulse voltammetry, respectively. The influences of twenty other amino acids, such as glutamine, L-glutamic acid, L-glysine, L-histidine, L-isoleucine, L-leucine, L-arginine hydrochloride, L-aspargine, L-aspartic acid, S-carboxy methyl-L-Cysteine, L-methionine, L-phenyl alanine, L-proline, L-serine, L-threonine, L-Cystine, cysteamine and gluthathione, on the current response of the sensor were examined. The obtained results did not show any influence on the analytical signal Of L-Cysteine by these amino acids (except for cysteamine). The method was also used for the selective determination Of L-Cysteine in patient-blood plasma and some pharmaceutical preparations by using standard addition method.
引用
收藏
页码:1213 / 1220
页数:8
相关论文
共 56 条
[21]  
Nekrassova O, 2002, ELECTROANAL, V14, P1464, DOI 10.1002/1521-4109(200211)14:21<1464::AID-ELAN1464>3.0.CO
[22]  
2-O
[23]  
Ojani R, 2002, ELECTROANAL, V14, P1197, DOI 10.1002/1521-4109(200209)14:17<1197::AID-ELAN1197>3.0.CO
[24]  
2-A
[25]   Electrocatalytic function of Bi(V) sites in heavily-doped PbO2-film electrodes applied for anodic detection of selected sulfur compounds [J].
Popovic, ND ;
Cox, JA ;
Johnson, DC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 455 (1-2) :153-160
[26]   Electrocatalytic characteristics of ascorbic acid oxidation at nickel plated aluminum electrodes modified with nickel pentacyanonitrosylferrate films [J].
Pournaghi-Azar, MH ;
Razmi-Nerbin, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 488 (01) :17-24
[27]   LIQUID-CHROMATOGRAPHY ELECTROCHEMICAL DETECTION OF HYDROXYLAMINES BY OXIDATION AT A COBALT PHTHALOCYANINE CHEMICALLY-MODIFIED ELECTRODE [J].
QI, XH ;
BALDWIN, RP .
ELECTROANALYSIS, 1994, 6 (5-6) :353-360
[28]   Selective oxidation of thiols to disulfides at polymeric cobalt phthalocyanine chemically modified electrodes [J].
Qi, XH ;
Baldwin, RP .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :1283-1287
[29]   ELECTROCHEMICAL PROPERTIES OF CARBON-PASTE ELECTRODES SPIKED WITH SOME 1,4-NAPHTHOQUINONE DERIVATIVES [J].
RAOOF, DJB ;
GOLABI, SM .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1995, 68 (08) :2253-2261
[30]   Differential pulse voltammetry determination of L-cysteine with ferrocene-modified carbon paste electrode [J].
Raoof, JB ;
Ojani, R ;
Kolbadinezhad, M .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2005, 78 (05) :818-826