Enhancement of UV disinfection efficiency by arraying inclined lamps

被引:4
|
作者
Lim, Seung-Joo
Lee, Yoon-Jin [1 ]
机构
[1] Cheongju Univ, Dept Environm Engn, Chungbuk 360764, South Korea
[2] Shingang Hi Tech Co Inc, Ecol & Environm Res Inst, Chungnam 330720, South Korea
关键词
UV disinfection; inclined lamp; UV dose; slope; diameter of the UV lamp; velocity;
D O I
10.1007/BF02706800
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A computational study on UV disinfection efficiency has been developed based on the Lambert-Beer law. Comparing a UV lamp arranged vertically to the flow of one arranged on an incline led to the conclusion that UV doses could be increased. The study of the inclination effect was divided into four stages in order to evaluate the increase in the UV dose at each stage. The slope of the inclined UV lamp ranged between 1 degrees and 89 degrees (0 degrees <theta < 90 degrees) with other parameters such as diameter of the UV lamp, distance from the surface of the UV lamp, and velocity also recorded. The increase of UV dosage was largely affected by the diameter and velocity of the UV lamp, especially on a lesser slope. To obtain a greater UV dose, it was necessary to assemble UV lamps with lesser slopes. By arranging lamps on an incline, UV disinfection could be enhanced.
引用
收藏
页码:595 / 600
页数:6
相关论文
共 50 条
  • [31] Development of UV distribution model for the non-contact type UV disinfection system
    Kim S.H.
    Choi Y.G.
    Kim D.
    International Journal of Chemical Reactor Engineering, 2011, 9
  • [32] Development of UV Distribution Model for the Non-Contact Type UV Disinfection System
    Kim, Sung Hong
    Choi, Young Gyun
    Kim, Dooil
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2011, 9
  • [33] Effect of Wastewater Ultraviolet Disinfection of Power Ultrasonic Enhancement
    Zhang, Shenghua
    Wu, Chundu
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 4890 - 4895
  • [34] Chemical pretreatment of combined sewer overflows for improved UV disinfection
    Gibson, J.
    Farnood, R.
    Seto, P.
    WATER SCIENCE AND TECHNOLOGY, 2016, 73 (02) : 375 - 381
  • [35] BATCH UV DISINFECTION FOR SMALL FLOW ONSITE WASTEWATER TREATMENT
    Liu, K.
    Park, E.
    Mancl, K. M.
    Lee, J.
    Tuovinen, O. H.
    APPLIED ENGINEERING IN AGRICULTURE, 2020, 36 (05) : 717 - 725
  • [36] Fouling mechanisms in a laboratory-scale UV disinfection system
    Nessim, Yoel
    Gehr, Ronald
    WATER ENVIRONMENT RESEARCH, 2006, 78 (12) : 2311 - 2323
  • [37] Kinetics of water disinfection using UV-C radiation
    Silva, Andreza B.
    Lima Filho, Nelson M.
    Palha, Maria A. P. F.
    Sarmento, Sandra M.
    FUEL, 2013, 110 : 114 - 123
  • [38] Ozone and UV254 Radiation for Municipal Wastewater Disinfection
    Blatchley, Ernest R., III
    Weng, ShihChi
    Afifi, Mehrnaz Zare
    Chiu, Hsiao-Han
    Reichlin, Douglas B.
    Jousset, Stephane
    Erhardt, Richard S.
    WATER ENVIRONMENT RESEARCH, 2012, 84 (11) : 2017 - 2027
  • [39] Bacteria sensitivity index of UV disinfection of bacteria with shoulder effect
    Tang, Walter Z.
    Sillanpaa, Mika
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2015, 3 (04) : 2588 - 2596
  • [40] Tertiary treatment using microfiltration and UV disinfection for water reclamation
    Jolis, D
    Hirano, R
    Pitt, P
    WATER ENVIRONMENT RESEARCH, 1999, 71 (02) : 224 - 231