Enhancement of UV disinfection efficiency by arraying inclined lamps

被引:4
|
作者
Lim, Seung-Joo
Lee, Yoon-Jin [1 ]
机构
[1] Cheongju Univ, Dept Environm Engn, Chungbuk 360764, South Korea
[2] Shingang Hi Tech Co Inc, Ecol & Environm Res Inst, Chungnam 330720, South Korea
关键词
UV disinfection; inclined lamp; UV dose; slope; diameter of the UV lamp; velocity;
D O I
10.1007/BF02706800
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A computational study on UV disinfection efficiency has been developed based on the Lambert-Beer law. Comparing a UV lamp arranged vertically to the flow of one arranged on an incline led to the conclusion that UV doses could be increased. The study of the inclination effect was divided into four stages in order to evaluate the increase in the UV dose at each stage. The slope of the inclined UV lamp ranged between 1 degrees and 89 degrees (0 degrees <theta < 90 degrees) with other parameters such as diameter of the UV lamp, distance from the surface of the UV lamp, and velocity also recorded. The increase of UV dosage was largely affected by the diameter and velocity of the UV lamp, especially on a lesser slope. To obtain a greater UV dose, it was necessary to assemble UV lamps with lesser slopes. By arranging lamps on an incline, UV disinfection could be enhanced.
引用
收藏
页码:595 / 600
页数:6
相关论文
共 50 条
  • [1] Enhancement of UV disinfection efficiency by arraying inclined lamps
    Seung-Joo Lim
    Yoon-Jin Lee
    Korean Journal of Chemical Engineering, 2006, 23 : 595 - 600
  • [2] The wastewater disinfection system of UV lamps based on can bus
    Wang, Song
    Liu, Mingguang
    Hao, Shengyu
    Li, Na
    2007 International Symposium on Computer Science & Technology, Proceedings, 2007, : 548 - 551
  • [3] What means "dose" in UV-disinfection with medium pressure lamps?
    Cabaj, A
    Sommer, R
    Pribil, W
    Haider, T
    OZONE-SCIENCE & ENGINEERING, 2001, 23 (03) : 239 - 244
  • [4] Characterization of permanent fouling on the surfaces of UV lamps used for wastewater disinfection
    Peng, J
    Qiu, Y
    Gehr, R
    WATER ENVIRONMENT RESEARCH, 2005, 77 (04) : 309 - +
  • [5] Enhancement of UV disinfection of urine matrixes by electrochemical oxidation
    Herraiz-Carbone, Miguel
    Cotillas, Salvador
    Lacasa, Engracia
    Pablo, Canizares
    Rodrigo, Manuel A.
    Saez, Cristina
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 410
  • [6] UV disinfection of water: the need for UV reactor validation
    Lawryshyn, YA
    Cairns, B
    WATER RECYCLING IN THE MEDITERRANEAN REGION, 2003, 3 (04): : 293 - 300
  • [7] Assessment of the UV/Chlorine Process in the Disinfection of Pseudomonas aeruginosa: Efficiency and Mechanism
    Wang, Liping
    Ye, Chengsong
    Guo, Lizheng
    Chen, Chunyan
    Kong, Xiujuan
    Chen, Yaoqing
    Shu, Longfei
    Wang, Peng
    Yu, Xin
    Fang, Jingyun
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (13) : 9221 - 9230
  • [8] The Impact of Unfiltered Source Water Characteristics on UV-LED Disinfection Efficiency
    Makuei, Mehrnaz Soleimanpour
    Peleato, Nicolas
    PROCEEDINGS OF THE CANADIAN SOCIETY FOR CIVIL ENGINEERING ANNUAL CONFERENCE 2023, VOL 8, CSCE 2023, 2024, 502 : 249 - 258
  • [9] Impact of Suspended Solids and Organic Matter on Chlorine and UV Disinfection Efficiency of Greywater
    Friedler, Eran
    F. Chavez, Diana
    Alfiya, Yuval
    Gilboa, Yael
    Gross, Amit
    WATER, 2021, 13 (02)
  • [10] Numerical and experimental investigation of UV disinfection for water treatment
    Li, H. Y.
    Osman, H.
    Kang, C. W.
    Ba, T.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 280 - 291