A Compton camera prototype for prompt gamma medical imaging

被引:21
作者
Thirolf, P. G. [1 ]
Aldawood, S. [1 ,2 ]
Boehmer, M. [3 ]
Bortfeldt, J. [1 ]
Castelhano, I. [1 ,4 ]
Dedes, G. [1 ]
Fiedler, F. [7 ]
Gernhaeuser, R. [3 ]
Golnik, C. [5 ,6 ]
Helmbrecht, S. [7 ]
Hueso-Gonzalez, F. [7 ]
Kolff, H. V. D. [1 ,8 ]
Kormoll, T. [5 ,6 ]
Lang, C. [1 ]
Liprandi, S. [1 ]
Lutter, R. [1 ]
Marinsek, T. [1 ]
Maier, L. [3 ]
Pausch, G. [5 ,6 ]
Petzoldt, J. [5 ,6 ]
Roemer, K. [7 ]
Schaart, D. [8 ]
Parodi, K. [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, D-85748 Garching, Germany
[2] King Saud Univ, Riyadh, Saudi Arabia
[3] Tech Univ Munich, D-85748 Garching, Germany
[4] Univ Lisbon, Lisbon, Portugal
[5] OncoRay Natl Ctr Radiat Res Oncol, Dresden, Germany
[6] Tech Univ Dresden, Dresden, Germany
[7] Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[8] Delft Univ Technol, Delft, Netherlands
来源
12TH INTERNATIONAL CONFERENCE ON NUCLEUS-NUCLEUS COLLISIONS 2015 | 2016年 / 117卷
关键词
BEAMS;
D O I
10.1051/epjconf/201611705005
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Compton camera prototype for a position-sensitive detection of prompt gamma rays from proton-induced nuclear reactions is being developed in Garching. The detector system allows to track the Compton-scattered electrons. The camera consists of a monolithic LaBr3:Ce scintillation absorber crystal, read out by a multi-anode PMT, preceded by a stacked array of 6 double-sided silicon strip detectors acting as scatterers. The LaBr3:Ce crystal has been characterized with radioactive sources. Online commissioning measurements were performed with a pulsed deuteron beam at the Garching Tandem accelerator and with a clinical proton beam at the OncoRay facility in Dresden. The determination of the interaction point of the photons in the monolithic crystal was investigated.
引用
收藏
页数:9
相关论文
共 13 条
  • [1] Beusch W., 1994, CERNECP9417
  • [2] Fiedler F., 2011, NUCL SCI S C REC NSS
  • [3] A Compton imager for in-vivo dosimetry of proton beams-A design study
    Kormoll, T.
    Fiedler, F.
    Schoene, S.
    Wuestemann, J.
    Zuber, K.
    Enghardt, W.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 626 : 114 - 119
  • [4] Sub-millimeter nuclear medical imaging with high sensitivity in positron emission tomography using β+γ coincidences
    Lang, C.
    Habs, D.
    Parodi, K.
    Thirolf, P. G.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [5] Lang C, 2015, THESIS
  • [6] Lojacono X., 2011, NUCL SCI S C REC, V1, P3518
  • [7] Prompt gamma measurements for locating the dose falloff region in the proton therapy
    Min, Chul-Hee
    Kim, Chan Hyeong
    Youn, Min-Young
    Kim, Jong-Won
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (18)
  • [8] Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient
    Polf, Jerimy C.
    Mackin, Dennis
    Lee, Eunsin
    Avery, Stephen
    Beddar, Sam
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09) : 2325 - 2340
  • [9] Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 87 - 94
  • [10] Design of a Compton camera for 3D prompt-γ imaging during ion beam therapy
    Roellinghoff, F.
    Richard, M. -H.
    Chevallier, M.
    Constanzo, J.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S20 - S23