Comparative Study between an Immediate Loading Protocol Using the Digital Workflow and a Conventional Protocol for Dental Implant Treatment: A Randomized Clinical Trial

被引:21
作者
Rattanapanich, Piyanut [1 ]
Aunmeungtong, Weerapan [1 ]
Chaijareenont, Pisaisit [2 ]
Khongkhunthian, Pathawee [1 ]
机构
[1] Chiang Mai Univ, Fac Dent, Ctr Excellence Dent Implantol, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Fac Dent, Dept Prosthodont, Chiang Mai 50200, Thailand
关键词
immediate loading; digital implant workflow; dental implant treatment; CAD; CAM; patient satisfaction; BONE-LEVEL CHANGES; SUBMERGED IMPLANTS; LOADED IMPLANTS; SINGLE IMPLANTS; FAILURE RATES; SURVIVAL; CROWNS;
D O I
10.3390/jcm8050622
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purposes of this randomized clinical trial study was to compare the immediate loading of dental implants while employing digital workflow and conventional implants in terms of the success rate, marginal bone level, and patient satisfaction. Methods: Fifty patients who had edentulous area on the mandibular premolar or molar area were included in the study. Twenty-five patients were assigned to immediate loading implant treatment using the digital technique and 25 patients were assigned to conventional loading implant treatment. In the first group, the patients were received digital impression (Cerec Omnicam, Dentsply Sirona((R)), York, PA, USA), designed, producing zirconia crown, and inserted on the same surgery day. The second group, after a healing period of three months, was received analog impression following conventional impression for the zirconia crown. Clinical outcome and radiographic bone level were evaluated after three, six, and 12 months. Patient satisfaction was measured at 12 months after inserting the implant. Results: There was no implants and protheses failure in both groups. The mean resonance frequency analysis values at the day of surgery were 78.26 +/- 4.09 in immediate loading using the digital group (ILD) and 73.74 +/- 5.14 in the conventional loading group (CL), respectively. Insertion torque values at the day of surgery were 36.60 +/- 12.64 in ILD and 38.8 +/- 12.19 CL, respectively. The marginal bone level in CL at three, six, and 12 months were 0.14 +/- 0.28 mm, 0.18 +/- 0.30 mm, and 0.17 +/- 0.29 mm, respectively, while in ILD at three, six, and 12 months were 0.18 +/- 0.33 mm and 0.16 +/- 0.27 mm and 0.15 +/- 0.31, respectively. There was no statistically significant difference between the two groups. Only one question in patient satisfaction's questionnaire was Now, can your dental implant and crown be used well? had been significantly different in favor to the conventional group. Conclusion: Within the limitation of this study, it may be concluded that, after one-year follow up, there were no statistically significant differences between the immediate loading of dental implants employed from the digital workflow and conventional implant treatment technique in the success rate and marginal bone level. In patient satisfaction, there was only statistic significant difference in question related to implant prosthetic function in favor of the CL group, whereas the question concerning speaking, cleansing, price, and expectation displayed no difference.
引用
收藏
页数:13
相关论文
共 26 条
  • [1] Albrektsson T, 1993, Aust Prosthodont J, V7 Suppl, P15
  • [2] Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
  • [3] Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles
    Arvidson, K
    Bystedt, H
    Frykholm, A
    von Konow, L
    Lothigius, E
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) : 225 - 234
  • [4] Non-submerged implants in the treatment of the edentulous lower jaw - A 2-year longitudinal study
    Astrand, P
    Almfeldt, I
    Brunell, G
    Hamp, SE
    Hellem, S
    Karlsson, U
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) : 337 - 344
  • [5] Becker W., 1967, INT J ORAL MAXILLOF, V12, P454
  • [6] Branemark PI., 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
  • [7] Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants
    Buser, D
    MericskeStern, R
    Bernard, JP
    Behneke, A
    Behneke, N
    Hirt, HP
    Belser, UC
    Lang, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 161 - 172
  • [8] Immediate nonfunctional versus immediate functional loading and dental implant failure rates: A systematic review and meta-analysis
    Chrcanovic, Bruno Ramos
    Albrektsson, Tomas
    Wennerberg, Ann
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (09) : 1052 - 1059
  • [9] CAD-CAM IN DENTISTRY
    DURET, F
    BLOUIN, JL
    DURET, B
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1988, 117 (06) : 715 - 720
  • [10] Annual failure rates and marginal bone-level changes of immediate compared to conventional loading of dental implants. A systematic review of the literature and meta-analysis
    Engelhardt, Sebastian
    Papacosta, Petros
    Rathe, Florian
    Oezen, Juelide
    Jansen, John A.
    Junker, Ruediger
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 671 - 687