A novel velocity estimator using multiple frequency carriers

被引:0
作者
Zhang, Z [1 ]
Jakobsson, A [1 ]
Nikolov, S [1 ]
Chambers, J [1 ]
机构
[1] Univ London Kings Coll, Ctr Digital Signal Proc Res, London WC2R 2LS, England
来源
MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING | 2004年 / 5373卷
关键词
aliasing; autocorrelation estimator; FFT; multiple frequency carriers; NLS;
D O I
10.1117/12.534512
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most modern ultrasound scanners use the so-called pulsed-wave Doppler technique to estimate the blood velocities. Among the narrowband-based methods, the autocorrelation estimator and the Fourier-based method are the most commonly used approaches. Due to the low level of the blood echo, the signal-to-noise ratio is low, and some averaging in depth is applied to improve the estimate. Further, due to velocity gradients in space and time, the spectrum may get smeared. An alternative approach is to use a pulse with multiple frequency carriers, and do some form of averaging in the frequency domain. However, the limited transducer bandwidth will limit the accuracy of the conventional Fourier-based estimator; this method is also known to have considerable variance. More mportantly, both the mentioned methods suffer from the maximum axial velocity bound, v(zmax) = cf(prf)/(4f(c)) over bar, where c is the speed of propagation. In this paper, we propose a nonlinear least squares (NLS) estimator. Typically, NLS estimators are computationally cumbersome, in general requiring the minimization of a multidimensional and often multimodal cost function. Here, by noting that the unknown velocity will result in a common known frequency distorting function, we reformulate the NLS estimator as an one-dimensional minimization problem confirmed by extensive simulations. The results show that the NLS method not only works better than both the autocorrelation estimator and Periodogram method for high velocities, it will also not suffer from the maximum velocity bound.
引用
收藏
页码:281 / 289
页数:9
相关论文
共 23 条
[1]   A REAL-TIME SYSTEM FOR QUANTIFYING AND DISPLAYING 2-DIMENSIONAL VELOCITIES USING ULTRASOUND [J].
BOHS, LN ;
FRIEMEL, BH ;
MCDERMOTT, BA ;
TRAHEY, GE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :751-761
[2]  
Edde B., 1993, RADAR PRINCIPLES TEC
[3]   BLOOD PERFUSION MEASUREMENT WITH MULTIFREQUENCY DOPPLER ULTRASOUND [J].
ERIKSSON, R ;
PERSSON, HW ;
DYMLING, SO ;
LINDSTROM, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01) :49-57
[4]  
EVANS DH, 2000, DOPPLER ULTRSOUND PH
[5]   Color flow mapping [J].
Ferrara, K ;
DeAngelis, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :321-345
[6]  
HOEKS APG, 1991, ULTRASOUND MED BIOL, V17
[7]  
HOSKINS PR, 1990, ULTRASOUND MED BIOL, V16
[8]  
Jensen J. A., 1996, MED BIOL ENG COMPUT, V34, P351
[9]  
Jensen J. A., 1996, Estimation of Blood Velocities using Ultrasound-A Signal Processing Approach
[10]   STATIONARY ECHO CANCELING IN VELOCITY ESTIMATION BY TIME-DOMAIN CROSS-CORRELATION [J].
JENSEN, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) :471-477